OverviewThe MI 2992 is a handheld three-phase power quality analyser with a 10.1” TFT colour touchscreen. It provides quick, guided setup for on-site measurements and supports both long-term recording and troubleshooting workflows. The instrument performs live measurements, historical data review and comprehensive on-device analysis for power quality assessment.
Measuring functions- Voltage: TRMS, DC, fundamental, under/over/peak, crest factor (4 channels)
- Current: TRMS, DC, fundamental, peak, crest factor (4 channels)
- Connection support: 1W, 2W (split), 3W, open delta, 4W, INV-3W, INV-1W
- Power measurements:
- Combined, fundamental, non-fundamental
- Active, non-active, apparent, inductive, capacitive
- Consumed and generated energy
- Load unbalance
- Unbalance and flicker measurements
- Harmonics up to the 63rd and harmonic pollution analysis
- Harmonic and inter-harmonic analysis, THD (voltage & current) and TDD:
- Absolute value
- % RMS
- % Fundamental
- Supraharmonics: 2.1–14.9 kHz (200 Hz bins)
- Harmonics phase angle
- Inrush current monitoring and recording, K-factor
- Event capture during recording: dips, swells, interruptions, RVC, inrush, alarms, signalling, transients
- Power quality analysis compliant with EN 50160 and IEEE 519
- Temperature measurement, power factor, displacement power factor
Key features- IEC 61000-4-30 Class A compliance
- High sampling frequency and predefined/custom recorder profiles (min. interval 200 ms)
- Built-in wide-range power supply; can be powered from P-N or P-P terminals
- Simultaneous capture of events, inrushes, RVCs and user-defined alarms
- NTP time synchronisation and automatic firmware update
- Remote access via VNC Viewer and online scope view for voltages/currents
- Internal eMMC storage + microSD support (up to 32 GB); data transfer via USB, SD, USB flash, Ethernet
- Automatic report generation (EN 50160, IEEE 519, Codigo de Red, Osinergimin) and export to .xls/.csv
- Recording intervals: 200 ms (special profile), 1 s … 2 h; two independent recording intervals for energy/demand and other values
- CAT IV 600 V / CAT III 1000 V overvoltage categories; direct connection to 1500 V DC with attenuator
- Support for DC, 50/60 Hz, 400 Hz and VFD modes
- 4 voltage channels up to 1000 VRMS; 4 current channels with automatic clamp recognition
- 10.1” TFT colour touchscreen; USB Type-C, Gigabit Ethernet, Wi‑Fi 802.11ac/a/b/g/n, Bluetooth 4.2/BLE
- Built-in Li‑Ion battery
SoftwareMPVision PC software enables downloading and advanced analysis of recorded data, automated post-processing and generation of detailed power quality reports. Supports local and remote data transfer and remote instrument control.
Standards applied- IEC/EN 61000-4-15 (Flickermeter)
- IEC/EN 61000-4-30 Ed. 3.0
- IEC/EN 61557-12
- IEEE 1459-2010
- IEEE 519
- EN 50160
- GOST 33073-2014, GOST R 54149:2010
Applications- Power generation and medium-voltage facilities
- Renewable energy systems and generator stator testing
- Low-voltage power quality assessment (UPS, site reports)
- Power supply and distribution monitoring, including healthcare power systems
Technical data- Dimensions: 320 x 230 x 60 mm
- Mass: 2.5 kg
Technical specifications- 4 voltage channels, up to 1000 VRMS
- 4 current channels, automatic clamp recognition
- Harmonics to 63rd; supraharmonics 2.1–14.9 kHz
- Recording intervals: 200 ms to 2 h
- Internal eMMC + microSD support (up to 32 GB)
- Connectivity: USB Type-C, Ethernet 10/100/1000, Wi‑Fi 802.11ac/a/b/g/n, Bluetooth 4.2/BLE
- Built-in Li‑Ion battery; input power 85–500 Vac
- Overvoltage category: CAT IV 600 V / CAT III 1000 V