Ultrasonic proximity sensor LCU-40APW series
cylindricaldigitalM12 connector

Ultrasonic proximity sensor - LCU-40APW series - Migatron - cylindrical / digital / M12 connector
Ultrasonic proximity sensor - LCU-40APW series - Migatron - cylindrical / digital / M12 connector
Ultrasonic proximity sensor - LCU-40APW series - Migatron - cylindrical / digital / M12 connector - image - 2
Add to favorites
Compare this product

Characteristics

Technology
ultrasonic
Shape
cylindrical
Output signal
digital
Electrical connection
M12 connector, terminal block, M8 connector
Supply voltage
24VDC, 12VDC, 15VDC
Mounting
threaded
Material
PVC, glass
Other characteristics
non-contact, compact, self-contained
Measuring range

Max.: 101.6 cm
(40 in)

Min.: 10.16 cm
(4 in)

Description

Analog Voltage Output Pulse Width Output Narrow Sensing Beam Self Contained Sensor Compact Design Input Voltage 11.8 – 30VDC Reverse Polarity Protection The LCU-40APW is a self-contained analog ultrasonic sensor housed in a PVC enclosure with 1-inch NPSM mounting threads and powered by 11.8–30 VDC with reverse polarity protection. It provides two outputs: a factory-calibrated analog voltage output fixed at 250 mV per inch, delivering 1–10 VDC over a 4–40 inch range, and a pulse width output that represents time-of-flight for direct distance measurement. Both outputs interface cleanly with PLC and computer-based control systems, with system resolution determined by the selected input card and scaling. The sensor supports terminal block or M8/M12 quick-disconnect connections, accommodates temperature compensation for varying air conditions, and integrates easily with Migatron set point controllers when discrete control is required. Specifications Power Input: - 11.8-30 VDC Reverse Polarity Protected Input Current: - 30mA, typical Ambient Temperature: - 0 – 60°C or 32 – 140°F Humidity: - 0 – 95% Non-Condensing Housing: - PVC with glass filled epoxy resin sensing face Outputs: Analog Voltage - Analog Voltage Output Non-Adjustable 250mV per inch (1V at 4″ & 10V at 40″) Load 4.7K Ohms to infinity Short Circuit Protected Pulse Width - Positive Pulse 5Vp with 90K Ohm load, Typical 3.3Vp with 6.8K Ohm load, Typical Transducer Frequency: - 170kHz, typical Response Time: Analog Voltage - 10-250ms, typical Pulse Width - 10ms, Typical Weight: - 3 ounces

Catalogs

LCU-40APW
LCU-40APW
2 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.