video corpo

Overload relay PCS-9611
earth-leakagephase lossunder-voltage

Overload relay - PCS-9611 - NR Electric - earth-leakage / phase loss / under-voltage
Overload relay - PCS-9611 - NR Electric - earth-leakage / phase loss / under-voltage
Add to favorites
Compare this product

Characteristics

Measured/monitored value
overload, earth-leakage, phase loss, under-voltage, current, power factor, frequency, under-frequency, over-current, phase unbalance, voltage, thermal, power, over-voltage, under-current, trip circuit, over-frequency
Network
three-phase
Applications
for feeder
Communication
RS485, Ethernet
Norms
IEC
Other characteristics
programmable, digital, configurable, with fault indication, multifunction

Description

Overview
The PCS-9611 is a feeder protection, control and monitoring relay designed for overhead lines, underground cables and transformer applications on solidly grounded, impedance grounded, Peterson coil grounded and ungrounded systems. It integrates a comprehensive function library, programmable logic, configurable I/O and frequency-tracking. Built on an advanced multiprocessor platform, the PCS-9611 fully complies with IEC 61850 station and process bus standards and supports IEC 61850-8-1 MMS, GOOSE and IEC 61850-9-2 Sampling Value.

Communication
  • Up to four 10Base-T/100Base-TX (RJ45) ports or two 100Base-FX ports; up to six 100Base-FX ports for IEC 61850-9-2 SV and GOOSE
  • IEC 61850-8-1 MMS and GOOSE for non-time-critical messaging; IEC 60870-5-103 over TCP/IP or DNP3.0 support
  • Two RS-485 rear ports with IEC 60870-5-103 and one additional RS-485 port for clock synchronization
  • One RS-232 rear port for printer and one faceplate RJ45 port for testing and configuration
  • Clock synchronization via pulse, IRIG-B and SNTP


Monitoring and Metering
  • Metering of current, voltage, active/reactive power, power factor, energy, frequency and harmonics
  • Circuit breaker monitoring and tripping circuit supervision
  • CT and VT failure supervision; line voltage failure detection
  • Self-diagnostic functions, fault recorder, 1024 SOE entries and 64 oscillograms (COMTRADE)


Protection and Control
  • Six-stage overcurrent protection (67P, 50P/51P) and six-stage neutral/ground overcurrent (67G, 50/51G)
  • Four-stage sensitive earth fault protection (67SG/51SG)
  • Two-stage under/overvoltage (27/59), negative sequence overvoltage (47) and zero-sequence overvoltage (59G)
  • Four-stage under-frequency, four-stage over-frequency and four-stage rate-of-change-of-frequency (81)
  • Breaker failure protection (50BF), dead zone protection (50DZ), negative sequence overcurrent (46) and broken conductor detection (46BC)
  • Thermal overload (49), undercurrent (37), switch-on-to-fault logic (SOTF), cold load pickup (CLP)
  • 4-shot three-pole auto-reclosing with sync-check and dead line/bus check (79/25), interlocking logic for busbar protection, remote/local breaker trip and close, fault locator
  • Automatic voltage and current drift adjustment; frequency tracking


Technical specifications
  • Model: PCS-9611
  • Advanced multiprocessor platform; IEC 61850 station and process bus compliant
  • Supports IEC 61850-8-1 MMS, GOOSE and IEC 61850-9-2 Sampling Value
  • Ethernet ports: up to 4x10/100Base-TX (RJ45) or 2x100Base-FX; up to 6x100Base-FX for time-critical messages
  • Serial ports: multiple RS-485 rear ports, RS-232 printer port
  • Clock synchronization: pulse, IRIG-B, SNTP
  • Protection functions: overcurrent, ground/neutral overcurrent, sensitive earth fault, under/overvoltage, negative/zero sequence protections, frequency protections, breaker failure, dead zone, broken conductor detection, thermal overload, undercurrent
  • Control and monitoring: auto-reclosing, sync-check, dead line/bus check, SOTF, CLP, interlocking and breaker remote/local control; metering, 1024 SOE, 64 oscillograms (COMTRADE)

Catalogs

No catalogs are available for this product.

See all of NR Electric‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.