Tripping current: 250 A
Motor protection is one of the central tasks of the electrical equipment of any machine. The electronically configurable ZEB electronic motor protection relays of the Eaton Moeller series ...
Tripping current: 0.4 A - 420 A
Trigger voltage: 1,000, 690 V
... or on an individual base, the RW_E electronic overload relays provide protection for electric motors up to 840 A. Main characteristics •Incorporated protections: overload, phase ...
Trigger voltage: 90 V - 690 V
The MP8000 is an advanced motor protection electronic overload relay that is fully programmable via Bluetooth* using an iPhone* or Android* smartphone or tablet with the Littelfuse App. It is easy to ...
Trigger voltage: 230, 24 V
... and accurate protection relays for every type of start. For 3-phase motors from 1 to 630 A and over. Cable feed through relay. Precise motor heating and cooling ...
FANOX ELECTRONIC
Tripping current: 4 A - 91 A
Trigger voltage: 230, 24, 115 V
... comes with a three-year guarantee. The relay works well for motors that need protection for every type of start. This relay is specially applicable to protect motor which need dependable ...
FANOX ELECTRONIC
Tripping current: 4 A - 10.3 A
Trigger voltage: 24 V
Fanox presents GEN generator protection relay. It has been designed for protection of low voltage generators up to 1000 Vac and up to 2000 A or higher currents. It is equipped with thermal ...
FANOX ELECTRONIC
Trigger voltage: 24, 110 V
Grid protection monitoring relay RE series; Frequency and voltage monitoring; Grid and system protection; Functionally Safe; Measuring voltage 3 x 400/230V AC; Supply voltage 24V DC, ...
Trigger voltage: 24 V - 110 V
... system protection monitoring relay RE series; Frequency and voltage monitoring; Functional safety; Measuring voltage 3 x 400/230V AC; Supply voltage 24V DC, 110-240V AC; 3 CO contacts; Width 107 mm; Installation ...
Relay to check voltage asymmetry, sequence and lack of phases 2 Module Three phase line 380...415V 50 and 60Hz Voltage asymmetry threshold adjustable 5...25% Adjustable intervention ...
... Controls, is an under voltage and overvoltage protection relay that functions as a protection against phase loss and phase reversal. ...
The unit is manufactured by GIC, and is a thermistor relay that is resistant against phase sequence, loss, and asymmetry faults. The device is also resistant to overheating in applications ...
... under or over voltage condition) - Phase sequence and phase failure - Neutral loss ( Only VEUM400N ) - Din rail mounting - 1 Exchange contact Typical application for control the under/over ...
SFR SERIES PHASE SEQUENCE AND PHASE FAILURE RELAY - Compact Size - 1 Module ( 17,5mm) - Phase sequence and phase loss - Phase ...
Trigger voltage: 400 V
EMAS
... ensuring start-up and cause the system to trip. ENTES Phase Failure (Motor Protection) Relays offer the perfect solution to these defects. They are designed to impart 100% efficient ...
Tripping current: 0.3 A - 1,500 A
Trigger voltage: 690 V
... motor protection relays • Electronics accurately identify excessive current or phase loss and react to conditions with greater speed, reliability and repeatability ...
Tripping current: 3, 5 A
Trigger voltage: 50 V - 500 V
3 phase RMS voltage protection relay Monitors: Over / Under Voltage, Over / Under Frequency, Phase asymmetry, Phase failure, Phase ...
SELEC Controls Pvt. Ltd.
Trigger voltage: 150 V - 416 V
The phase sequence and phase failure protector trip relay is designed to monitor the correct phase rotation or sequence of a three-phase ...
Trigger voltage: 110, 208, 380, 400, 415 V
... Monitors own three phase, 3-wire supply - Detects incorrect phase sequence and phase loss - Adjustable Trip levels and Time delay - SPDT Relay output - ...
Broyce Control
Tripping current: 11.5 A
... Features • Rated current up to 630 A at 600 Vac, 50/60 Hz • Overload protection trip Class 10 A • Phase loss sensitivity • Adjustable current setting for overload protection • ...
Tripping current: 5 A
Protection relay against overload, underload, and phase loss. With display. Codes and references - 10002217 TPM5-230 - 10002218 TPM5-400 - 10002451 TPM5/5-230 - ...
... of additional specific protection functions for motor industrial applications. Its versatility makes it the perfect solution for oil & gas, minery and all heavy-duty environments. Applications Metering & protection ...
Orion Italia
Trigger voltage: 100 V - 460 V
KCG593x - LOSS OF MAINS RELAY (DEAD MAINS PROTECTION) Protects a paralleled generator from feeding power into a non-line grid (3-wire or 4-wire systems) Generator to Grid Protection ...
Meagacon AS
The MBS Series, manufactured by Vostermans Ventilation, is a motor protective circuit breaker that is suitable for eliminating the need for a motor reload relay. It is equipped with a rated current of ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining