Modbus RTU I/O module CN-8011
digitalanalogRS485

Modbus RTU I/O module - CN-8011 - ODOT Automation - digital / analog / RS485
Modbus RTU I/O module - CN-8011 - ODOT Automation - digital / analog / RS485
Modbus RTU I/O module - CN-8011 - ODOT Automation - digital / analog / RS485 - image - 2
Modbus RTU I/O module - CN-8011 - ODOT Automation - digital / analog / RS485 - image - 3
Modbus RTU I/O module - CN-8011 - ODOT Automation - digital / analog / RS485 - image - 4
Add to favorites
Compare this product

Characteristics

Signal type
digital, analog
Interface
Modbus RTU, RS485, Fieldbus
Number of inputs/outputs
16 digital inputs, 8-I/O, 16 digital outputs, 8 analog inputs, 32 digital outputs
Type
distributed, remote, network
Applications
for sensors, automation, PLC, voltage, temperature, for HMI interface, for the food industry, for temperature sensors, centralized automation, for thermocouples, for RTD
Mounting
DIN rail
Size
mini
Other characteristics
compact, configurable, rugged, slave, IP, flexible

Description

CN-8011 Modbus-RTU Network Adapter  Module Overview CN-8011 Modbus-RTU network adapter supports standard Modbus-RTU communication, it supports function code of 01/02/03/04/05/06/15/16/23, and this device could monitor the IO module communication state in real time. Technical Parameter Adapter Hardware Parameter System Power Nominal Reverse Protection: YES :24Vdc, Range: 19.2~28.8VDC Power Consumption:30mA@24Vdc Internal Bus Supply Current Max: 2.5A@5VDC Isolation:System Power to Field Power Isolation Power Supply Nominal: 24Vdc, Range:19.2~28.8VDC Field Power Current:Max. DC 8A IO Modules Supported:32 pcs Wiring:Max.1.5mm²(AWG 16) Mounting Type:35mm DIN-Rail Size:115*51.5*75mm Weight:130g Environment Specification Operation Temperature -40~85℃ Operation Humidity 5%-95% (No Condensation) Protection: IP20 Modbus-RTU Parameter Protocol: Modbus-RTU/ASCII Function Code: 01 / 02 / 03 / 04 / 05 / 06 / 15 / 16 Baud Rate: 2400~115200bps Station No. : 1~63(Dial-code switch configuration),64~247(Software configuration) Interface: 5 Pin screw terminal Data Bits: 7, 8 Parity Checking: None, Even, ODD Stop Bit: 1, 2 Max. bus length: 1200m( RS485, 2400 baud rate) Terminal resistance and offset resistance: Dial-code switch configuration