Product OverviewA 600 kVA bidirectional AC/DC power conditioning system (PCS) providing accurate four-quadrant power conversion with both source and sink capability. Supports a wide AC input/output voltage range, multiple operating modes, fast current response and regenerative load/grid simulation for industrial test and energy management applications.
Key Features- AC/DC power supply and grid simulation with regenerative sink
- Four-quadrant operation with power and load emulation
- Control modes: Constant Voltage (CV), Constant Current (CC), Constant Power (CP) and R/L/C emulation
- Active/reactive current and power control
- Comprehensive protections: over temperature, over/under voltage, over current
- 7-inch touchscreen LCD user interface
- Communication: RS-485 (Modbus) and CAN; PC control software
- Peak shaving support with battery integration
Technical SpecificationsInput: 3-phase, 3/4-wire, 220–480 V (±10% AC); Current: 0–918.5 A (±10% AC); Power: 600 kVA @380–480 V, 350 kVA @220 V; Frequency: 50/60 Hz (±3 Hz)
Output: 3-phase, 3/4-wire, 220–480 V (±10% AC); DC 0–±400 V or 0–800 V (optional); Current: 0–±918.5 Aac; 0–±375 Adc (optional up to 0–±1125 Adc); Power: 600 kVA @380–480 Vac, 350 kVA @220 Vac; DC: 150 kW @400 Vdc (optional 300–600 kW @800 Vdc); Response time: ≤ 1 ms; Current accuracy: ≤ 1% of rated; Current ripple: ≤ 5% (with grid voltage source)
Efficiency: ≥ 95% (rated); Cooling: forced air (fan); Isolation: non-isolated; Interface: 7-inch touch LCD; Communications: CAN, RS-485 (Modbus); Protections: over temperature/current, over/under voltage; Dimensions: 1000 × 850 × 1950 mm; Weight: approx. 1000 kg; Operating: 0–40 °C; Humidity: 10–90% RH (non-condensing)
Technical Data / Specifications- Rated AC power: 600 kVA @380–480 V (350 kVA @220 V)
- DC rated power: 150 kW @400 Vdc (optional 300–600 kW @800 Vdc)
- AC/DC input voltage: 220–480 V (±10%)
- Output DC range: 0 to ±400 V (or 0 to 800 V optional)
- Max AC current: up to ±918.5 Aac; DC up to ±375 Adc (optional up to ±1125 Adc)
- Response time: ≤ 1 ms; Current accuracy: ≤ 1% of rated
- Efficiency: ≥ 95% at rated output
- Cooling: forced air (fan-cooled)
- Isolation: non-isolated design
- User interface: 7-inch touch LCD
- Communications: CAN, RS-485 (Modbus)
- Protections: over temperature, over current, over/under voltage
- Dimensions: 1000 × 850 × 1950 mm; Weight: approx. 1000 kg
- Operating conditions: 0–40 °C; 10–90% RH non-condensing