Digital temperature controller GZ series
processRS-485universal

Digital temperature controller - GZ series - RKC INSTRUMENT INC - process / RS-485 / universal
Digital temperature controller - GZ series - RKC INSTRUMENT INC - process / RS-485 / universal
Digital temperature controller - GZ series - RKC INSTRUMENT INC - process / RS-485 / universal - image - 2
Digital temperature controller - GZ series - RKC INSTRUMENT INC - process / RS-485 / universal - image - 3
Add to favorites
Compare this product

Characteristics

Display
digital
Use
process
Other characteristics
RS-485, universal, voltage output
Maximum temperature

Min.: -10 °C
(14 °F)

Max.: 55 °C
(131 °F)

Description

Input type (Universal input) : ※See the Input Range Code for the input range. 1)Thermocouple : K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII 2)RTD: Pt100 and JPt100 (3-wire system) 3)DC voltage/current: 0 to 10mV, 0 to 100mV, 0 to 20mA, 4 to 20mA 4)DC voltage: 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, -5 to +5V,-10 to +10V Sampling time: 0.01 sec. Measurement accuracy : ±(0.1% of displayed value+1 digit) ※Depends on the input and the range. Output 1 (OUT1) ※Control, Event, HBA (Heater Break Alarm), LBA (Control loop break alarm) or analog retransmission are assigned. 2)Voltage pulse output for SSR driving: 0/12V dc 3)Current output : 0 to 20mA, 4 to 20mA dc 4)Continuous voltage output: 0 to 5V, 1 to 5V, 0 to 10V dc 5)Transistor output: Allowable load current: 100 mA Output 2 (OUT2) ※Control, Event, HBA (Heater Break Alarm), LBA (Control loop break alarm) or analog retransmission can be assigned 1)Relay contact output (b): 1a contact ※Highly durable relay 2)Voltage pulse output for SSR driving: 0/12V dc 3)Current output : 0 to 20mA, 4 to 20mA dc 4)Continuous voltage output: 0 to 5V, 1 to 5V, 0 to 10V dc 5)Transistor output: Allowable load current: 100 mA Output 3 (OUT3) ※Universal output 1) Voltage pulse output for SSR driving: 0/14 dc Digital output (DO: max.4 points) Relay contact output: 1a contact Event function (max.4 points) Event inputs (Max.6 points) Function of event inputs: RUN/STOP switching, AUTO/MAN switching, selecting Input 2, Interlock release, Peak/Bottom value release,

Catalogs

AG500
AG500
108 Pages
COM-ME-1
COM-ME-1
2 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.