Supports 90 - 264 VAC / 127 - 370 VDC
Efficiencies up to 87 %
Protection against short circuit, overload, overvoltage & over temperature
Cooling by free air convection
UL 508 approved (E522848)
Specifications
Input Voltage - 90 - 264 VAC (127 - 370 VDC)
Input Frequency - 50/60 Hz
Inrush Current - < 48 Amps; Measured at 264 VAC, 25°C Ambient, Cold start
Output Voltage - 5V to 48V
Output Power - 60 W
Voltage Tolerance - ± 1 %
Line Regulation - < 1% of Vout
Load Regulation - ± 1 %
Turn On Time - < 1 sec @ 230 VAC & < 3 sec @ 115 VAC, Full load
Hold Up Time - ≥60ms at 230V AC & ≥15ms at 115V AC, Full load
Rise Time - 110% of rated output current; Hiccup type; Autorecovery
Overvoltage Protection - Latched type; Input AC power to be recycled to recover the power supply
Output Short Circuit Protection - Hiccup mode when output is shorted; Autorecovery type
Operating Temperature - - 25°C to + 70°C; De-rate linearly above 50°C from 100 % load at 50°C to 50 % load at 70°C,- 25°C to 0°C start-up is guaranteed with specification deviation
Storage Temperature - - 40°C to + 85°C
Cooling - Natural convection cooled
Humidity - 5 to 95 % RH, Non condensing
Altitude - 2000 m
Dimension - 43 x 109.8 x 102.7 mm (W x H x D)
Weight - 285 gms
Mounting - 35 mm Din rail