The VEL/GLF produces a signal proportional to the velocity component of a mechanical vibration by means of relative movement between a coil and a magnet. The coil is suspended within the field of the magnet by means of diaphragms which permit virtually frictionless movement in one axis only. This measuring axis is coincident with the axis of the cylindrical body. Internal compensation circuitry provides a frequency response extension down to 0.5Hz in combination with a standard IEPE current loop interface.
Piezoelectric based velocity vibration sensors are susceptible to many forms of interference on most machine applications that can result in spurious readings and alarms. Typical causes include, low frequency base strain effects due to temperature changes amplified through the internal signal processing, high frequency and high g vibration events caused by auxiliary machine items resulting in transducer saturation and also mains voltage interference due to a combination of a poor local plant earth and insufficient transducer internal isolation.
Features
Velocity Vibration Sensor
High Noise Immunity
IEPE Interface
Low frequency response to 0.5Hz
High sensitivity 20mV/mm/s
Top or Side exit connector and cable options
Excellent high frequency vibration rejection
Wide Supply Voltage Range
Double cased unit with excellent isolation
Applications
Heavy Industrial Environments
Hydro Electric and Wind Turbines
Cooling Tower Fans
Low Speed Pumps
Integrated signal conditioning
Operating Temperature range -40°C to +100°C