Climate chamber THV-1500 (A~F)
thermostatictemperaturehumidity

Climate chamber - THV-1500 (A~F) - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity
Climate chamber - THV-1500 (A~F) - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity
Climate chamber - THV-1500 (A~F) - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 2
Climate chamber - THV-1500 (A~F) - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 3
Climate chamber - THV-1500 (A~F) - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 4
Climate chamber - THV-1500 (A~F) - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 5
Climate chamber - THV-1500 (A~F) - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 6
Add to favorites
Compare this product

Characteristics

Type
climatic, thermostatic
Controlled parameter
temperature, humidity
Test type
vibration
Product applications
electronic equipment, for automobiles
Application domain
for quality control, for the aeronautical industry, international standards-compliant, laboratory
Chamber material
stainless steel
Options and accessories
touchscreen-controlled, with temperature and climatic control, with cyclical temperature/humidity control
Temperature

Min.: -75 °C
(-103 °F)

Max.: 200 °C
(392 °F)

Interior length

Min.: 600 mm
(23.62 in)

Max.: 1,500 mm
(59.06 in)

Interior height

Min.: 850 mm
(33.46 in)

Max.: 1,500 mm
(59.06 in)

Interior depth

Min.: 800 mm
(31.5 in)

Max.: 1,500 mm
(59.06 in)

External length

Min.: 850 mm
(33.5 in)

Max.: 1,800 mm
(70.9 in)

External height

Min.: 1,950 mm
(76.77 in)

Max.: 2,400 mm
(94.49 in)

External depth

Min.: 2,100 mm
(82.68 in)

Max.: 3,000 mm
(118.11 in)

Description

Overview
ISO 16750-3 Temperature Humidity Combined Vibration Test System simulates the condition of temperature, humidity, and vibration to test materials or products' properties. It is widely applied to aerospace products, information electronic instruments and meters, materials, electrical and electronic products, and various electronic SAP parts under combined temperature, humidity and vibration environments. When the test piece is tested by the system, the vibration (sinusoidal or random), temperature (high or low), humidity and electric stress are combined and applied according to the specified period to reflect environmental conditions during transportation and use.

Chamber Specification — THV Series
Parameter | THV-408 (A~F) | THV-1000 (A~F) | THV-1500 (A~F)
Internal Dimension W×H×D (mm) | 600 × 850 × 800 | 1000 × 1000 × 1000 | 1500 × 1500 × 1500
External Dimension W×H×D (mm) | 850 × 1950 × 2100 | 1300 × 2200 × 2400 | 1800 × 2400 × 3000
Temperature Range | Low: (A) 25 °C / (B) 0 °C / (C) −20 °C / (D) −40 °C / (E) −60 °C / (F) −70 °C / −75 °C; High: 100 °C (150 °C / 200 °C optional)
Humidity Range | 20–98% R.H. (10–98% / 5–98% available with dehumidifier)
Control Accuracy | ±0.5 °C; ±2.5% R.H.
Rising / Falling Velocity | Rising: 0.1–3.0 °C/min; Falling: 0.1–1.0 °C/min (min. 1.5 °C/min optional)
Protection Devices | Fuse-free switch; compressor overload; high/low coolant voltage; over-humidity and over-temperature; fault warning; water short-storage warning.

Matched Shaker Specification — ES Series
Model | Sine Force (N) | Random Force (N) | Frequency (Hz) | Acceleration (m/s²) | Speed (m/s) | Displacement (p-p) mm | Max. Load (kg) | Coil Mass (kg) | Coil Size (mm)
ES-3 | 3000 | 3000 | 3–3500 | 1000 | 1.6 | 25 | 100 | 3.5 | Φ150
ES-3a | 3000 | 3000 | 3–3500 | 400 | 1.6 | 40 | 120 | 9 | Φ230
ES-6 | 6000 | 6000 | 3–3500 | 1000 | 1.6 | 25 | 180 | 6.5 | Φ230
ES-6a | 6000 | 6000 | 3–3500 | 1000 | 1.6 | 51 | 250 | 12 | Φ230
ES-10 | 10000 | 10000 | 3–3000 | 1000 | 1.8 | 51 | 270 | 14 | Φ240
ES-20 | 20000 | 20000 | 3–3000 | 1000 | 1.8 | 51 | 300 | 30 | Φ320
ES-30 | 30000 | 30000 | 3–2800 | 1000 | 1.8 | 51 | 450 | 40 | Φ450
ES-40 | 40000 | 40000 | 3–2800 | 1000 | 1.8 | 51 | 500 | 50 | Φ450
ES-50 | 50000 | 50000 | 3–2700 | 1000 | 1.8 | 51 | 750 | 50 | Φ450
ES-60 | 60000 | 60000 | 3–2700 | 1000 | 1.8 | 51 | 750 | 60 | Φ450
ES-100 | 100000 | 100000 | 3–2500 | 1000 | 1.8 | 51 | 1000 | 90 | Φ450

Features
  • Integration: Chamber and refrigeration in one unit — compact design with independent console reduces floor space and installation time.
  • Coverage: Six temperature grades (A–F) to −75 °C; pick grade to match test standard; optional higher high-temperature range (150 °C / 200 °C).
  • Durability: SUS 304 stainless steel interior — corrosion resistant and stable in repeated humidity cycles.
  • Flexibility: Matched ES-Series shaker options from 3,000 N to 100,000 N to suit DUT weight and required force.

System Composition
  • Test Chamber: Combined temperature and humidity control with SUS 304 interior.
  • Refrigeration: Tecumseh (France) and Bizer (Germany) compressor units.
  • Humidity Control: Automatic control; optional dehumidifier for low-humidity tests.
  • Vibration Bench: Matched ES-Series electrodynamic shaker selected by DUT weight and force.
  • Touch Controller: LCD touch screen with RS-232 communication for programmable profiles.

Deliverables & Service
  • Installation & Operation Manual: Setup documentation with wiring diagrams and start-up checklist.
  • Export Packing List & Shipping Documents: Complete freight documentation including commercial invoice.
  • 12-Month Warranty: Covers chamber, refrigeration system, and controller.
  • Standard Lead Time: ~20 working days for standard builds; 30–40 working days for customized builds.
  • Lifetime Remote Technical Support included.

Standards & Applications
Supported standards include IEC 68-2-1 (Cold), IEC 68-2-2 (Dry Heat), IEC 68-2-3 (Damp Heat — Steady State), IEC 68-2-30 (Damp Heat — Cyclic), IEC 68-2-14 (Change of Temperature), MIL-STD-810G/F (Environmental Test), and ISO 16750-3 (Road Vehicles — Mechanical Loads).
Typical applications: Aviation & Aerospace; Automotive Components; Electronics & PCB Assemblies; Telecommunications; Shipping & Transportation; Research & University Labs; Testing & Certification Bodies; Material R&D Companies.

caractéristiques / spécifications techniques
  • Model Series: THV Series (chambers available: THV-408, THV-1000, THV-1500)
  • Internal Dimensions (mm): THV-408 = 600 × 850 × 800; THV-1000 = 1000 × 1000 × 1000; THV-1500 = 1500 × 1500 × 1500
  • External Dimensions (mm): THV-408 = 850 × 1950 × 2100; THV-1000 = 1300 × 2200 × 2400; THV-1500 = 1800 × 2400 × 3000
  • Temperature Range: Low grades A–F from 25 °C down to −70/−75 °C; High: standard 100 °C (150/200 °C optional)
  • Humidity Range: 20–98% R.H.; options 10–98% / 5–98% with dehumidifier
  • Control Accuracy: ±0.5 °C; ±2.5% R.H.
  • Temperature Change Rate: Rising 0.1–3.0 °C/min; Falling 0.1–1.0 °C/min (1.5 °C/min optional)
  • Protection: fuse-free switch, compressor overload protection, high/low coolant voltage protection, over-humidity and over-temperature alarms, fault warning, water short-storage warning
  • Matched Shaker Range: ES-Series 3,000 N up to 100,000 N; frequency ranges typically 3–2500 / 3–3500 Hz depending on model
  • Controller: LCD touch screen, programmable profiles, RS-232 communication
  • Interior Material: SUS 304 stainless steel
  • Warranty & Support: 12-month warranty; lifetime remote technical support; standard lead time ~20 working days

Catalogs

No catalogs are available for this product.

See all of AI SI LI (China) Test Equipment Co., Ltd‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.