• EIA-310 compliant 19 in. rack, 2U height
• 2 IEC 60320-C13 permanent AC outlets
• 12 IEC 60320-C13 sequential AC outlets
• 24 VDC power outlet
• 230 VAC 1-phase mains input
• 2 Inputs for temperature control
• Emergency Power-Off button according to IEC 60947-5-1 and IEC 60204-1
• Emergency stop function according to temperature status
• LED for line presence
• LED for temperature status
• Main switch ON/OFF
• Mains fuses
• Residual current circuit breaker according to IEC 61008-1 and IEC 62423
• CE certified
• Electro Magnetic Compatibility directive compliant
• Low Voltage directive compliant
Tame-Test’s secure single-phase Power Distribution Unit (PDU) is a sequential power distribution box that supplies the test bench and its measuring instruments with AC power and ensures constant temperature monitoring in the rack. This 2U rack-mountable drawer can be perfectly integrated into a standard 19″ test bay.
It allows, in particular:
• To facilitate the power distribution of all the test bench components, the measuring instruments such as an oscilloscope or multimeter, or any utility line power supply
• To limit the high current inrush when the bench is powered up and to avoid untimely short-circuits when several loads are switched on in the test equipment (up to 12 simultaneously), thanks to a sequential start-up per block of 4 sockets
• To ensure the operational safety of the users thanks to two dry contact thermostat inputs allowing a pre-alarm and a cut-off of the output sockets
To cut off the inverter that may be present in the test bench, thanks to the emergency stop