For more fieldbus device connection space
PROFIBUS, DeviceNET, CANopen
Fieldbus cover for direct cabling on a construction site
Features
Customer-specific solutions
Flexible programming
Further interfaces available
Modular mechanical design
Modular product line
Nominal voltage
Specific value
24 VDC
Limit values, min/max
11/27 VDC
Nominal current, typically
Specific value
80 mA
Condition
unloaded
Device design
Type
Single-/Multi-Turn
Total resolution
<= 31 Bit
Number of steps per revolution
<= 8192
Number of revolutions
<= 256000
Output capacity
<= 30 Bit
SSI - Interface
SSI-Clock input
Optocoupler
SSI-Data output
RS-422, 2-wire
SSI-Clock frequency
80…1000 kHz
SSI-Mono time, typically
20 µs
Cycle time
250 µs, internal
Parameter/Function, changeable
Resolution
Output code
Output format
Movement status signal
Limit switch
Error signal
Preset parameter
Parity
Direction signal
Overspeed
Counting direction
Type of parametrization
programmable
Programming - Tool
TR-Soft: TRWinProg
External inputs
F/R
Count direction
Preset
electronic adjustment
Logic level
"0“ < +2V, "1“ = Supply
External outputs
Output level
Supply voltage, <= 50 mA
Type of parametrization
programmable
Number of outputs
8
Output stages
Push Pull
Equipment
Option
Short-circuit proof
yes
Maximum Speed, mechanically
<= 6000 1/min
Shaft load, axial/radial
<= 40 N, = 3.9E+10 revolutions
Bearing life time - Parameter
Speed
3000 1/min
Operating temperature
60 °C
Shaft load, axial/radial
<= 20 N, <= 30 N
Point of origin, shaft load
at the shaft end