- Robotics - Automation - Industrial IT >
- Automation >
- Analog I/O >
- ADVANTECH
ADVANTECH analog I/O
... container DIN43880 9 modules for rail mountain, there are 4 controllers with universal input and a wide range of outputs, both analogue for ritransmission and control and relay for actuation on systems with alternating ...
Pixsys
The Module SOC-8 is made for controlling the minimal-power output devices through RS-485. With this, it search its function in distributed control and visualization systems. This function can straightly control other DC loads having 24 ...
The Module SIAi-8 is made for enabling the measure analog ranges from 8 current inputs through the RS-485 connection with a speed rate of 10 Hz. Due to one of available capabilities, measurement results can be recalculated. ...
The SIN-8 enables the user to monitor 8 binary voltage inputs through the RS-485 connection. Its operating functions can be installed with standard visualization software. The direct current of the unit is 24 V. Its operating temperature ...
R-D/A4, R-D/A8, R-D/A16 are modules with 4, 8, 16 optically isolated analog outputs (16bit ±10V) that send reference signals to drives, servocontrols, power solid state relays with linear input, or retransmit variables ...
The programmable I/O modules of the Saia PCD1 E-Line series with Saia PG5® enable the autonomous and safe operation of the modules even if communication to the master station is interrupted. The local function of a room, ...
The modules in the Saia PCD1.E-Line S-Series for HVAC applications have a mix of analogue and digital inputs and outputs. With 6 to 12 data points per module, they can be combined easily and are an economical addition ...
... 3 to 11. Each I/O Module has 16 inputs and 8 outputs. Up to 31 I/O Modules can be connected to a single Controller, thus providing a total of 496 inputs and 242 outputs. The I/O Module ...
Analogue inputs plug-in card for the OMR 700 is fully isolated from the internal bus with a galvanic isolation also between individual inputs. The design of the cards allows their use at any position in the device. If ...
Orbit Merret s.r.o.
... order another card and insert it into a free slot. In this manner the device can "grow" with your requirements. 4x Analogue input, isolated Pt 50/100/1000, Ni 1000/10 000, Cu 50/100
Orbit Merret s.r.o.
... order another card and insert it into a free slot. In this manner the device can "grow" with your requirements. 4x Analogue input, isolated range: J/K/T/E/B/S/R/N/L
Orbit Merret s.r.o.
The universal Input / Output module UG 9461 has analogue inputs and 2 analogue outputs. It can be used to connect thermocouples and thermistors and offers 2 configurable measuring inputs 0-10V or 0-20mA. ...
IOB1 – for timing measurement of larger circuit breakers The IOB1 offers six additional input and six additional output channels for CIBANO 500. What does it do? IOB1 is controlled by CIBANO 500 via EtherCAT®-communication. With ...
... protocol module and I/O module plug and play, features as below: 1. designed with a max of 64 modules, each I/O module is built with 16 channels and each have LED indicator. 2.supports an overall of 1024 ...
ODOT Automation
... ~85℃ Operational Humidity: 5%-95% (No Condensation) Protection Class: IP20 Profinet Parameter Protocol: Profinet IO Device I/O Data Size: Input Max.1440 Bytes, Output Max.1440 Bytes RT: YES,Min.1ms IRT: ...
ODOT Automation
The CN-8033 EtherCAT I/O module supports standard EtherCAT protocol access. The adapter supports a Max. input of 1024 bytes and a Max. output of 1024 bytes. It supports 32 pcs of extended IO modules. Hardware ...
ODOT Automation
KEB’s C6 Remote I/O system offers various options for connecting process signals to an EtherCAT network. It is made up of a C6 Remote I/O bus coupler and additional I/O modules. The C6 ...
OCS-I/O is a modular I/O system for OCS offering a fieldbus network (CsCAN) from the CNX116 base. It is a flexible I/O system that can be applied as a local expansion I/O or as remote ...
Horner Automation
... additional points of I/O to any solution and is a great choice for expanding X-Series OCS when one or more digital or analogue I/O are required. SmartMod+ I/O are so ...
Horner Automation
... indicator lights for each I/O point, power and network status -DIN-rail mountable SmartBlock range covers advanced I/O modules like AC Power Monitor, Isolated Thermocouple modules, high resolution ...
Horner Automation
2 Universal analog input channels Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE High-accuracy digitization 24-bit ADC, 100 ...
Gantner Instruments
1 Analog input channel measuring half and full bridge, IEPE-sensor, voltage, current, quarter bridge with completion terminal 1 Analog output channel voltage (±10 V) or current ...
Gantner Instruments
8 analog input channels thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic ...
Gantner Instruments
DeviceNet Analog Remote I/O (Terminal Block Type) The ARD-A series analog remote I/O units provide input/output expansion and communication for various devices using ...
... ServerSave time and wiring cost with peer-to-peer communicationSupports SNMPv1/v2c/v3Friendly configuration via web browserSimplify I/O management with MXIO library for Windows or Linux platformsWide operating temperature ...
Programmable analog output modules with 2 outputs for FRER Network Analyzers The M52U... modules with 2 or 4 analogue outputs allow, when connected to a FRER multifunctional analyser, to generate up ...
Programmable analog output modules with 4 outputs for FRER Network Analysers The M52U... modules with 2 or 4 analogue outputs allow, when connected to a FRER multifunctional analyser, to generate up ...
Z-4DI-2AI-2DO is a I/O module with 4 digital inputs, 2 analog inputs, 2 relay outputs, slave for Modbus RTU, on two RS485 serial ports. The module allows the possibility to set the parameters via USB ...
SENECA | Automation Interfaces
ZE-4DI-2AI-2DO is an I/O module with 4 digital inputs, 2 analog inputs, and 2 digital relay outputs, for slave communication over ModbusTCP-IP (Ethernet) and Modbus RTU. The module has server functionality ...
SENECA | Automation Interfaces
ZE-2AI is an I/O module with 2 analog inputs for slave communication over Modbus TCP-IP (Ethernet) and Modbus RTU. The module has server functionality for the 100 Mbit/s Ethernet communication port with ...
SENECA | Automation Interfaces
... we also offer FOX I/O modules for signal processing of 2-16 channels and special functions such as pulse width modulation. This ensures that you always have the right I/O modules for every application. The ...
... systems we also offer FOX I/O modules for signal processing of 2-16 channels and special functions such as pulse width modulation. This ensures that you always have the right I/O modules for every application. Analog ...
Multi I/O is a device that integrates UPS into a control system using fully configurable input and output relay signals. It can be used to connect two devices to a single UPS serial communication port. It can be used ...
Cost-optimized CANopen-slave-I/O module for the extension of the inputs/outputs of a master control unit via CAN. The communication of the master control unit takes place via CANopen or a layer 2 protocol. The ESX.iox fulfils the safety ...
(STW) Sensor-Technik Wiedemann GmbH
The ESX.3ios is a CAN-I/O module for the extension of the inputs/outputs of a master control unit via CAN. The communication with the master control unit takes place via CANopen, CANopen Safety, the STW protocol ECeS ...
(STW) Sensor-Technik Wiedemann GmbH
... multifunction inputs, one module identification output, one digital output and one fixed voltage output for sensor supply. All analog signals are processed with a 12-bit resolution.
(STW) Sensor-Technik Wiedemann GmbH
... turnkey material test systems (MTS). Equipped with four strain gauge-based transducer input channels, four general purpose analog input channels, and a 3-axis motion controller, the PCI-9524 delivers a complete hardware ...
The Fieldbus technology is suitable with Schlegel control units particularly for operations utilizing a big number of control units and pilot lights to be connected to the fieldbus with little wiring. The choice to network the Schlegel ...
CANopen module with 4 analog Inputs • Resolution: Up to 20 bits • Programmable input voltage range: ±10V • Easy control cabinet wiring due to 3-lead connection • CANopen profiles according to CiA® ...
esd electronics gmbh
CANopen module with 8 analog Inputs • 8 A/D-Converter Inputs • Resolution: 14 bit • Input voltage range: ±10.24 V • Sample rate: up to 100 μs / 8 channels simultaneously • CANopen profiles according ...
esd electronics gmbh
... with 4 analog outputs • Resolution: 12 bits plus sign • Output voltage range: ±10V • CANopen profiles according to CiA® specification CiA 301 and CiA 401 Approved Reliability and Ease of Use • ...
esd electronics gmbh
Up to PLd in accordance with EN ISO 13849-1 and SIL2 in accordance with IEC 61508 Screwless terminals for easy installation Status diagnostics via control outputs and LEDs Number of sensors can be increased to 4 per ...
... with 8 digital I/O and two 12-bit analog outputs PCI-based 16-channel, 12-bit, 1.25 MS/s DAQ board with 8 digital I/O and two 12-bit analog outputs PCI-based 64-channel, ...
Measurement Computing
... sight distances of up to 10km for the 805U and 20 miles for the 905U are achievable. • Point-to-point digital and/or analogue I/O transfer • Easy to use - no configuration necessary • Secure data ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining