Range: 20 mm - 500 mm
... Light spot size [at sensor distance] - 2 mm x 6 mm Measurement range - 20 ... 500 mm Resolution - 0.1 ... 0.5 mm Accuracy, short range - 2 % Accuracy, distant range - 4 % Reference value, ...
Leuze electronic GmbH + Co. KG
Range: 25 mm - 400 mm
... Residual ripple - 0 ... 10 %, From UB Open-circuit current - 30 ... 50 mA Switching hysteresis - 5,000 µm Number of analog outputs - 1 Piece(s) Number of digital switching outputs - 1 Piece(s) Load resistance ...
Leuze electronic GmbH + Co. KG
Range: 600 mm - 6,000 mm
... teach inputs - 1 Piece(s) Voltage type - DC Switching voltage - high: 0.9 x UB low: ≤ 2 V or not connected Number of analog outputs - 1 Piece(s) Number of digital switching outputs - 1 Piece(s) Load resistance ...
Leuze electronic GmbH + Co. KG
Range: 600 mm - 6,000 mm
... teach inputs - 1 Piece(s) Voltage type - DC Switching voltage - high: 0.9 x UB low: ≤ 2 V or not connected Number of analog outputs - 1 Piece(s) Number of digital switching outputs - 1 Piece(s) Load resistance ...
Leuze electronic GmbH + Co. KG
Range: 350 mm - 6,000 mm
... V, DC Residual ripple - 0 ... 5 %, From UB Open-circuit current - 0 ... 50 mA Switching hysteresis - 1 % Number of analog outputs - 1 Piece(s) Number of digital switching outputs - 1 Piece(s) Load resistance ...
Leuze electronic GmbH + Co. KG
Range: 250 mm - 3,500 mm
... V, DC Residual ripple - 0 ... 5 %, From UB Open-circuit current - 0 ... 50 mA Switching hysteresis - 1 % Number of analog outputs - 1 Piece(s) Number of digital switching outputs - 1 Piece(s) Load resistance ...
Leuze electronic GmbH + Co. KG
Range: 250 mm - 3,500 mm
... V, DC Residual ripple - 0 ... 5 %, From UB Open-circuit current - 0 ... 50 mA Switching hysteresis - 1 % Number of analog outputs - 1 Piece(s) Number of digital switching outputs - 1 Piece(s) Load resistance ...
Leuze electronic GmbH + Co. KG
Range: 50 mm - 400 mm
... V, DC Residual ripple - 0 ... 7 %, From UB Open-circuit current - 0 ... 50 mA Switching hysteresis - 1 % Number of analog outputs - 1 Piece(s) Number of digital switching outputs - 1 Piece(s) Load resistance ...
Leuze electronic GmbH + Co. KG
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining