Metrofunk armored cables

1 company | 63 products
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.productLabel}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.productLabel}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
data electrical cable
data electrical cable
UL-11Y series

Temperature: -25 °C - 80 °C
Nominal voltage: 90 V
Cross-section: 0.25, 0.34 mm²

UL - 11Y paired Data/control signal cables with small outer diameters, halogen-free, fire-retardant Technical data Highly flexible core structure, tightly twisted pairs. The cables have a shield ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LifYCY series

Temperature: -10 °C - 80 °C
Nominal voltage: 100 V - 500 V
Cross-section: 0.08, 0.5, 0.2, 0.14 mm²

... Preferred application Pulse and data transfer connection cables for electronic systems, control and regulation systems, measurement and signalling systems and as interconnection cables for paging ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LifY(CB)Y-CY

Temperature: -10 °C - 80 °C
Nominal voltage: 100 V
Cross-section: 0.08 mm²

... data Highly flexible data transfer cables Pairs tightly twisted, each pair shielded and insulated, full shielding. Preferred application Interference-free transfer of data at low currents; pulse ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LiYCY-CY

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.25 mm²

... of a shielded pair is 3.90 + 0.10 mm; Jacket colour light grey as per RAL 7032. Twisted structure: 1 to 32 of these shielded and insulated core pairs are twisted to form the cable. Full ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LiYCY

Temperature: -10 °C - 80 °C
Nominal voltage: 500 V
Cross-section: 0.75 mm²

LiYCY 2 to 3 x 0.75 mm2 and 2 x 2 to 6 x 2 x 0.75 mm2 Technical data Twisted-pair control signal cable with full shielding and light blue jacket (RAL 5015) Special features The full shielding prevents interference ...

See the other products
Metrofunk Kabel-Union
connection electrical cable
connection electrical cable
LIY-LIY(CB)-Y

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.14 mm²

... core pair in each cable (white and brown) is wrapped with a layer of transparent polyester foil (15 x 0.019 mm) and almost 100% shielded by braided, plain copper wire over this foil. The ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LiYCY

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.14 mm²

... twisted pairs Preferred application Connection cables for electronic systems (e.g. computers, printers, etc.), control and regulation systems, measurement and signalling systems and as interconnection cables ...

See the other products
Metrofunk Kabel-Union
power cable
power cable
JE-LiYCY

Temperature: -5 °C - 70 °C
Nominal voltage: 600 V
Cross-section: 0.5 mm²

... (2 x 2 to 12 x 2) x 0.50 mm2 Technical data Flexible installation cable for power station systems and industrial electronic systems Preferred application Connection cables for control and regulation ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
J-Y(ST)Y

Temperature: -5 °C - 70 °C
Nominal voltage: 220 V
Cross-section: 0.28 mm²

... in plastics and the additional copper drain wire provide 100% shielding against external electrical interference. The large production quantities resulting from the many possible applications make these cables ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
Li2Y(C)H-C11Y AWG 24

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.22 mm²

... twisted pair individually shielded and insulated, full shielding, halogen-free Preferred application Pulse and data transfer connection cables for electronic systems, control and regulation systems ...

See the other products
Metrofunk Kabel-Union