- Hydraulics - Pneumatics >
- Filter and Separator >
- Condensate drain >
- LIMING
LIMING condensate drains
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Operating pressure: 16 bar
Operating temperature: 2 °C - 65 °C
... EMD12 series drain is designed for fully automatic discharging of condensate or any other non-aggressive fluid from compressed air system. The units can be installed as external drain on any application ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 0 bar - 16 bar
... AOK16B is designed for fully automatic discharging of condensate or any other nonaggressive fluid from compressed air⁽¹⁾ system. AOK16B is easy to install inside to the filter housing. AOK16B can be used in variety of applications. For ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 50 bar
... EMD HP series drain have been developed for fully automatic discharging of condensate or any other non-aggressive fluid from compressed air⁽¹⁾ system. The units can be installed as external drain on any ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 16 bar - 50 bar
... TD M timer controlled condensate drain is designed for reliable removal of condensate or other liquid from compressed air system ⁽¹⁾. Discharge intervals can be set with two adjustment knobs. TD M drain ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 0 bar - 400 bar
Operating temperature: 2 °C - 150 °C
... TD420M timer controlled condensate drain is designed for reliable removal of condensate or other liquid from high pressure compressed air system. Discharge intervals can be set with two adjustment knobs. ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 20 bar
Operating temperature: 2 °C - 65 °C
... screw), after-cooler cyclone condensate separator pressure vessel/air tank air dryer air filter. The unit allows for fully automatic discharge of condensate and other non-aggressive fluid from compressed air(1) systems. ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 50 bar
... designed for fully automatic discharging of condensate or any other nonaggressive fluid from compressed air ¹ system. The unit can be installed as external drain on any application specified below. Condensate ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 16 bar
... AOK16B is designed for fully automatic discharging of condensate or any other nonaggressive fluid from compressed air⁽¹⁾ system. AOK16B is easy to install inside to the filter housing. AOK16B can be used in variety of applications. For ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 16 bar
... AOK16F is designed for fully automatic discharging of condensate or any other nonaggressive fluid from compressed air⁽¹⁾ system. AOK16F is easy to install inside to the filter housing. AOK16F can be used in variety of applications. For ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 16 bar
... from compressed air system. In order to prevent condensate from becoming re-entrained in the airstream this product suggests controlling the condensate level in filter bowl, requiring an automatic drain ...
OMEGA AIR d.o.o. Ljubljana
Operating pressure: 40 bar - 630 bar
Operating temperature: 425 °C - 650 °C
... Thermostatic steam traps for removing condensate from steam or for venting steam pipes. In steam traps with GESTRA Thermovit regulators, the opening and closing process is controlled by the interaction ...
GESTRA AG
Operating pressure: 25 bar - 40 bar
Operating temperature: 225 °C - 450 °C
... Thermostatic steam traps for removing condensate from steam or for venting steam pipes A distinguishing feature of the MK series is the outstanding responsiveness of the membrane regulator. It is especially suitable ...
GESTRA AG
Operating pressure: 16 bar - 160 bar
Operating temperature: 200 °C - 550 °C
... Steam traps with ball float for removing condensate from steam, cold condensate or distillates without banking-up The traps with the tried and tested rolling ball seal work with exceptionally ...
GESTRA AG
Operating pressure: 63, 40 bar
Operating temperature: 400, 300, 450 °C
... Steam traps for draining steam pipes, trace heaters and steam systems These steam traps work on the basis of a simple thermodynamic principle. Incoming condensate lifts the valve disk of the regulator ...
GESTRA AG
Operating temperature: 400 °C
... connection to universal connectors, we offer: Steam traps with membrane regulator – MK 36A-71/-72 Bimetallic steam traps – BK 36A-7 Thermodynamic steam traps – DK 36A-7 Inverted bucket steam traps ...
GESTRA AG
Operating pressure: 40, 150, 300 bar
Operating temperature: 450 °C
... Automatic drainage valve AK 45 Replaces hand-operated or separately operated valves on start-up The AK 45 rapidly and automatically discharges air and condensate from steam systems on start-up and drains ...
GESTRA AG
Operating pressure: 16, 25 bar
Operating temperature: 300, 400 °C
... Duo Super steam traps TK 23, TK 24 Drainage rate: up to 140 tons of condensate an hour TK 23 and TK 24 Duo Super steam traps are highly responsive steam traps with ...
GESTRA AG
Operating pressure: 10, 16 bar
Operating temperature: 300 °C
... Drainage rate: up to 390 tons of condensate an hour GK 11 and GK 21 Super steam traps are manually controlled traps with integrated sightglass. GK 11 and GK 21 steam traps ...
GESTRA AG
... backstreaming by absorbing hydrocarbons Traps water vapor Regeneration using built-in heater Type 304 stainless steel trap body Available in five connection sizes ISO KF and LF ports Molecular Sieve Traps ...
MDC vacuum products
... Traps all types of condensable vapors Two-piece clamped body for easy maintenance Type 304 stainless steel trap body Aluminum centering ring with Viton® O-ring Low LN2 consumption Liquid nitrogen traps ...
MDC vacuum products
Operating pressure: 2 bar - 10 bar
... Float type automatic drain *“SA” automatic drain allows draining condensate, which is within the bowl, both when it is pressurized and depressurized. *Float type functianing allows draining ...
Aircomp by Stampotecnica
Operating pressure: 2 bar - 12 bar
... *“SAD” automatic drain allows draining condensate, which is within the bowl, both when it is pressurized and depressurized. *It is a differential type drain: when the condensate ...
Aircomp by Stampotecnica
Operating pressure: 0 bar - 13 bar
Operating temperature: 5 °C - 50 °C
... opened, thus ensuring that all settled fluid particles are eliminated. Equipped with hose nipple to convey the collected condensate away. To allow servicing operations, pressure can be relieved by slackening the knurled part at the ...
Aircomp by Stampotecnica
Operating pressure: 65 bar
Discharge capacity: 590 kg/h
Operating temperature: 510 °C
... Thermodynamic steam trap operates on the principle of generation of “Flash Steam” and corresponding increase in localised velocity and reduction in pressure under the disc. FEATURES Thermodynamic steam trap with ...
Pennant Engineering
Operating pressure: 175 bar
Discharge capacity: 630 kg/h
Operating temperature: 537 °C
... Thermodynamic steam trap operates on the principle of generation of “Flash Steam” and corresponding increase in localised velocity and reduction in pressure under the disc. FEATURES Thermodynamic steam trap with ...
Pennant Engineering
Operating pressure: 42 bar
Discharge capacity: 759 kg/h
Operating temperature: 426 °C
... Thermodynamic steam trap operates on the principle of generation of “Flash Steam” and corresponding increase in localised velocity and reduction in pressure under the disc. FEATURES Thermodynamic steam trap with ...
Pennant Engineering
Operating pressure: 50 bar
Discharge capacity: 735 kg/h
Operating temperature: 426 °C
... Thermodynamic steam trap operates on the principle of generation of “Flash Steam” and corresponding increase in localised velocity and reduction in pressure under the disc. FEATURES Thermodynamic steam trap with ...
Pennant Engineering
Operating pressure: 18 bar
Discharge capacity: 350, 530 kg/h
Operating temperature: 220 °C
... Cannot discharge condensate as it forms. There is always upstream condensate built-up. If bucket vent is blocked, the trap gets locked. Trap must be installed with Bucket in vertical ...
Pennant Engineering
Operating pressure: 11 bar
Discharge capacity: 265 kg/h
Operating temperature: 220 °C
... Cannot discharge condensate as it forms. There is always upstream condensate built-up. If bucket vent is blocked, the trap gets locked. Trap must be installed with Bucket in vertical ...
Pennant Engineering
Operating pressure: 11, 13, 14 bar
Discharge capacity: 280, 390, 565 kg/h
Operating temperature: 220 °C
... Cannot discharge condensate as it forms. There is always upstream condensate built-up. If bucket vent is blocked, the trap gets locked. Trap must be installed with Bucket in vertical ...
Pennant Engineering
Operating pressure: 22, 30 bar
Discharge capacity: 840, 866 kg/h
Operating temperature: 426 °C
... Thermostatic Steam Trap with bimetallic column with inbuilt strainer, Forged steel construction, SS internals, End conns.: Screwed NPT / BSPT / BSP / SW / FL.*PT40 Bimetal steam trap can be provided for pressures up-to ...
Pennant Engineering
Operating pressure: 22 bar
Discharge capacity: 686 kg/h
Operating temperature: 220 °C
... Balanced Pressure Thermostatic Steam Trap with inbuilt strainer. Forged steel construction, SS Internals, End conns.: Screwed NPT / BSPT / BSP / SW / FL ...
Pennant Engineering
Operating pressure: 22 bar
Discharge capacity: 450 kg/h
Operating temperature: 220 °C
... Balanced Pressure Thermostatic Steam Trap with inbuilt strainer. Complete SS construction End conns.: Screwed NPT / BSPT / BSP / SW ...
Pennant Engineering
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group