Pico encapsulated transformers

Output power kVA: 0.03 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24 V - 230 V
... SINGLE PHASE ISOLATING TRANSFORMERS IP00 Modern and economical make of general purpose isolating and/or safety transformers for building into installations and industrial or power engineering devices. ...
BREVE-Tufvassons

Electric power: 7.5 kVA - 440 kVA
Primary voltage: 460 V - 575 V
Secondary voltage: 133 V - 460 V
... SCR (Silicon Control Rectifier) variable speed motor drive applications, a transformer is needed to magnetically isolate the incoming line from the motor drive. The transformer must also provide a voltage ...
SolaHD

Primary voltage: 110 V - 240 V
Secondary voltage: 24, 48, 110, 220 V
Secondary current: 10 A - 10,000 A
Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor)... GENERAL SPECIFICATIONS Internal isolation transformer ...
Tescom

Primary current: 400 A - 5,000 A
Secondary current: 5 A
... Multiplexer Toroidal Current Transformers are mostly used in cases where all measuring conductors cannot be passed through a toroidal current transformer. CT-1S provides a vectorial sum by using X/5 ...

... case current transformers are used if high currents are to be recorded and further processed. The line to be measured (conductor rail or wire) is fed through the window opening and forms the primary circuit for the plug-on ...
Janitza electronics GmbH

Economical Low leakage inductance and interwinding capacitance Fast rise time: 3nSec typical Low profile 16-pin DIP (14-pin available) Surface mount design available Choice of turns ratio, 1:1 or 2:1

Electric power: 0.0006 kVA - 0.0032 kVA
Primary voltage: 24 V - 440 V
Secondary voltage: 6 V - 24 V
... minimal sizes availlable test certifications to ENEC 10-, VDE, UL- and CSA-regulations absolutely short-circuit-proof vaccum encapsulated, bobbin with dual chamber windings temperature class ta 40C/F and ta 70C/F hight ...
HAHN - Elektrobau

Primary voltage: 275, 500, 200, 550 V
Secondary voltage: 275, 500, 200, 550 V
Primary current: 40,000, 15,000 A
HIGH ATTENUATION ISOLATION TRANSFORMERSWITH OVERVOLTAGE PROTECTION IREM Isolation Transformers of the RS series are characterized by: the high attenuation of common mode disturbances; the attenuation of overvoltages ...
IREM SPA

Output power kVA: 10 kVA
Primary voltage: 600 V
Secondary voltage: 600 V
PhaseSingle FrequencyBased on customers' requirement Capacity10KVA Max. Voltage600V Max. Inductance RangeBased on customers' requirement Insulation LevelClass A / B / F
Leader Electronics Inc.

Primary voltage: 415 V
Secondary voltage: 230 V
Salvo Transformer Powered Doors Salvo Transformer is used to convert power supplies of 415VAC down to 230VAC. It is only required on sites where 230VAC is not available. It is supplied as mounted in ...

Primary current: 5,000 A
GIS current transformers type JK GIS are used in GIS applications. Features • Single- or three-phase current transformers • Free choice of mounting position • Mounted outside or inside ...
PFIFFNER International AG

The current transformer is part of the control circuit. It is used to measure the current so that the temperature controller can determine the heatsealing band temperature: PEX-W5 standard version with additional UL ...

Output power kVA: 3,150 kVA
Primary voltage: 36 kV
ELETTROMECCANICA COLOMBO manufactures distribution oil transformers , low voltage/low voltage(LV/LV) medium voltage/low voltage(MV/LV) and medium voltage/medium voltage (MV/MV) up 3,15 MVA and 36 KV. The transformers ...

Primary current: 16 A
Partial Discharge High Frequency Current Transformer – Clamp on, clamp off for live machine fittings ø30mm and ø50mm The HFTC-0030 and HFTC-0050 Partial Discharge High Frequency Current Transformers ...
Sparks Instruments SA

Electric power: 0 W - 3,500,000 W
Technical features Power : Up to 3500 kVA Frecuency : 50-60 Hz Isolators : Class F or H Winding : Class HC-200ºC Protection degree : IP-00 to IP-65 Nema 1 to Nema 4X Environment Temperature : 40ºC Standards : UNE-EN 61558-2-1 UNE ...
EREMU

Primary voltage: 2.4 kV - 36 kV
Secondary voltage: 120 V - 600 V
... Distribution Transformer Product Overview The single-phase pole-mounted distribution transformer adopts high quality silicon steel sheet iron core, mounted on the pole,which have small size and small ...

Primary voltage: 6.4 V - 11 V
Secondary voltage: 3.2 V - 5.5 V
The AS0028100 and AS0028101 are not really part of the Copper IRIG-B Distribution System but they are derived from the Model 10882 IRIG-B Distribution Tap. They work with modulated IRIG-B and isolates the source from the end device. The ...

Primary voltage: 230, 115 V
Secondary voltage: 6 V - 24 V
Primary current: 10 mA - 83 mA
Options · Packaging unit: 50 pieces · Bulk packaging is standard · Custom design available Features · It is miniaturised to be easily PCB mounted. · It has very high insulation of 4000Vrms Hi-pot. · It accords with UL94V-0 flammability ...
Tianchang Yunchen Electronics Industry and Trade Co., Ltd.

... drive transformers combine high power density with high insulations strengths. Benefits: • Reinforced insulation • Low coupling capacitance • Low leakage inductance • Large voltage-time area in compact designs Gate ...
Vacuumschmelze GmbH & Co. KG

Secondary voltage: 6 mV - 21 mV
Primary current: 8.5 mA - 25 mA
Application: Heater Over Current Sensor Earth leakage breaker Ground fault circuit interrupter Residual current circuit breaker U.P.S. (Uninterrupted Power System) Protection of Inverter (Air Conditioner etc) Application leakage ...
Thousand Hundred Industrial Co., Ltd.

Primary voltage: 0.7 kV
Primary current: 100 A - 4,000 A
Secondary current: 5 A
ABS-encapsulated and rectangularly shaped, these split-core, window-type, low-voltage current transformers are self-extinguishing and have a high level of insulation and moisture resistance. ABS-encapsulated ...
CHALLENGE INDUSTRIAL CO., Ltd

Electric power: 40 W
Primary voltage: 230, 400 V
Secondary voltage: 230 V
EDR 230TC40 Single-phase control transformer IP20 - for DIN-rail mounting - Upri 15-230-400V // Usec 0-0-230V - Power 40VA - Inrush power 90VA
EREA Transformers


Electric power: 9, 3, 6, 15 kVA
Primary voltage: 480 V
Secondary voltage: 208, 120 V
Acme’s low voltage distribution transformers are designed for industrial and commercial applications. All of Acme’s general purpose transformers are rated for 600 volts and below. Encapsulated ...
Acme Electric

Electric power: 0.4, 0.5, 0.005, 0.06 kVA
Primary voltage: 3,000 V - 35,000 V
Secondary voltage: 100, 110, 120 V
... Silko CT and VT series are high-voltage instrument transformers that are suitable for use in measuring and protecting high-voltage distribution systems of 3.6kV up to 40.5kV. In addition, these transformers ...
Your suggestions for improvement:
Subscribe to our newsletter