Pico single-phase transformers
Electric power: 0.04 W - 5 W
Primary voltage: 230, 400 V
Secondary voltage: 24 V - 230 V
Products in the LH-series are single-phase safety isolating / isolation transformers, which are protected against direct contact. Products in the LH-series are designed with maximum versatility ...
Muuntosähkö Oy - Trafox
Primary voltage: 230, 400 V
Secondary voltage: 24 V - 230 V
Frequency: 50, 60 Hz
Products in the XH-series are single-phase safety isolating / isolation transformers, which are protected against direct contact. Products in the XH-series are designed with maximum versatility ...
Muuntosähkö Oy - Trafox
Primary voltage: 230 V
Secondary voltage: 230 V
Frequency: 50, 60 Hz
Encapsulated mobile single-phase electrostatically shielded transformers are suitable for equipment which need to be protected from mains power transients and interference. The transformers ...
Muuntosähkö Oy - Trafox
Output power kVA: 0.063 kVA - 20 kVA
Primary voltage: 230 V
Secondary voltage: 24 V
Output power kVA: 25 kVA - 10,000 kVA
Primary voltage: 36 kV
Secondary voltage: 36 kV
... Type Transformers from 25 kVA up to 10.000 KVA up to 36 kV voltage class. Cast Resin Transformers are a cost-effective and convenient alternative to traditional high voltage Oil Immersed Power and Distribution ...
Timsan Transformateur
Output power kVA: 25 kVA - 4,000 kVA
Primary voltage: 36 kV
Secondary voltage: 36 kV
* Cooling Type: ONAN or Customized * Vector Group: YZN, DYN or Customized * Conducting Material: Electrolytic Copper or Electrolytic Aluminum. * Geographical Conditions: Concerned country’s conditions ( Altitude, Humidity, Temperature ...
Timsan Transformateur
Output power kVA: 25 kVA - 8,000 kVA
Primary voltage: 36 V
Secondary voltage: 36 kV
* Cooling Type: ONAN or Customized * Vector Group: YZN, DYN or Customized * Conducting Material: Electrolytic Copper or Electrolytic Aluminum. * Geographical Conditions: Concerned country’s conditions (Altitude, Humidity, Temperature ...
Timsan Transformateur
Primary voltage: 110 V - 240 V
Secondary voltage: 24, 48, 110, 220 V
Secondary current: 10 A - 10,000 A
Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor)... GENERAL SPECIFICATIONS Internal isolation transformer ...
Output power kVA: 4,000 kVA - 50,000 kVA
Secondary voltage: 3.3 kV - 66 kV
Frequency: 60, 50 Hz
... Frequency : 50 or 60Hz • Vector Group : single phase or three phase transformers with possibility of star and/or delta connections in any of its windings. • Number ...
Sami Trafo Makina Insaat Imalat Taah. Genel Tic. Ltd. Sti.
Output power kVA: 25 kVA - 5,000 kVA
Secondary voltage: 1.1 kV - 36 kV
Frequency: 60, 50 Hz
... IEEE, NEMA, TS EN60076. Std Transformer is Design, manufacturing and exporting 53 Countries of the Distribution Transformers. Std Transformer is Design, manufacturing and exporting 53 ...
Sami Trafo Makina Insaat Imalat Taah. Genel Tic. Ltd. Sti.
Output power kVA: 50 kVA - 2,500 kVA
Secondary voltage: 1.1 kV - 36 kV
Frequency: 50, 60 Hz
... Frequency : 50 or 60Hz • Vector Group : single phase or three phase transformers with possibility of star or delta connections in any of its windings. • Number Of Windings ...
Sami Trafo Makina Insaat Imalat Taah. Genel Tic. Ltd. Sti.
Output power kVA: 3.15 kVA - 10 kVA
Primary voltage: 230 V
Secondary voltage: 230, 115 V
... series medical isolation transformers are designed compatible with IEC 60364-7-710 standards for power supply of single phase IT systems and produced in accordance with IEC 61558-2-15 ...
Output power kVA: 25 kVA - 3,150 kVA
Primary voltage: 7.2 kV - 36 kV
Frequency: 50, 60 Hz
... the following transformers: • Three phase distribution hermetically sealed Transformers • Single-phase distribution hermetically sealed Transformers • ...
Secondary voltage: 5 V - 120 V
... VA are both concentric wound. Low primary to secondary coupling - no electrostatic shield required. Choice of economical single primary 115V - 60 Hz only (161 series) or the universal dual primary 115/230V - 50/60 Hz ...
Hammond
Output power kVA: 333 kVA
Primary voltage: 33 kV
Secondary voltage: 120 V - 480 V
Single Phase Distribution Transformers are compact in size and elegant in appearance. These transformers are manufactured by using the highest quality materials, employing ...
Primary voltage: 132 kV
Secondary voltage: 3.3 kV - 66 kV
Frequency: 50, 60 Hz
These are basically step-down transformers reducing transmission/sub-transmission voltage to primary feeder level. Standard Fittings Primary bushings Secondary bushings Off circuit tap changer Pressure relief ...
Primary voltage: 66 kV - 500 kV
Frequency: 50, 60 Hz
... protection, provide voltage signals for control devices. Electronic transformer is the trend of meter transformer development. Contrast to the conventional instrument transformer, electronic ...
The voltage transformer with isolating device is designed for maintenance and testing conveniently that there is no need to dismount VTs. The voltage transformer is provided with isolating device to open ...
Primary voltage: 110 kV
JDQXFH-110 series single-phase voltage transformer is used in 110kV SF6 enclosed composite apparatus, connected between phases and ground for voltage and electrical energy ...
Output power kVA: 0.06 kVA - 1 kVA
Primary voltage: 230 V - 690 V
Secondary voltage: 6 V - 48 V
safety isolating / Control Transformer, IP00 Open single-phase safety isolating transformer designed and tested according to norm EN61558-2-6. Separate insulated windings and protected ...
Primary voltage: 230 V
Execution in accordance to VDE 0570 / EN 61558 Prepared for units to protective class II Protective type IP 00 Thermal class E Nominal ambient temperature ta 40°C Input voltage: 230V Output voltage: up to 42V Frequency: 50/60Hz Impregnation Test ...
Electric power: 0.025 kVA - 0.63 kVA
Primary voltage: 230, 400 V
Secondary voltage: 230, 400 V
ENTES isolating transformers ensure the safe operation on the secondary side by isolating them from the primary voltage. Input output voltages of isolating transformers are fixed (230 or 400V). The electrical ...
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 0 V - 440 V
Secondary voltage: 12, 24, 48, 110, 230 V
CL Range CL Range Control Panel Transformers offering 230V with input tappings or 400V with input tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated ...
Boardman Transformers
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 15 V - 400 V
Secondary voltage: 0 V - 230 V
MCL Range MCL Range Control Panel Transformers offering 230V and 400V with adjustment tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated winding and ...
Boardman Transformers
Electric power: 3 kVA - 40 kVA
Primary voltage: 230, 415 V
Primary current: 7.22 A - 173.91 A
Larger single-phase Transformers using UI two limb construction. The Transformers conform to IEC61558 and IEC60076 and are available with a range of voltage and connection ...
Boardman Transformers
It uses EI high quality silicon steel sheet.The installation height is 25.5mm.applicable for triggering single or double narrow pulse SCR below 100A.
Primary voltage: 230, 220, 110 V
Secondary voltage: 7.1 V - 28.6 V
Primary current: 104 mA - 833 mA
Characteristics:1.Vacuum encapsulated,100℃/six hours high temperature aging,service life 20 years ,high dielectric strength. 2.High quality silicon steel sheet,Low temperature rise,High efficiency. 3.PBT project plastic, environmental ...
Primary voltage: 230, 220, 110 V
Secondary voltage: 7.6 V - 28.7 V
Primary current: 208 mA - 1,667 mA
Characteristics:1.Vacuum encapsulated,100℃/six hours high temperature aging,service life 20 years ,high dielectric strength. 2.High quality silicon steel sheet,Low temperature rise,High efficiency. 3.PBT project plastic, environmental ...
Output power kVA: 40,000 kVA
Primary voltage: 15 kV - 20 kV
Primary current: 12,500 A - 22,000 A
Dry type frequency injection transformer installed in the HVB/HVA source stations in the building, enabling the injection of remote control signals. An injection unit comprises 3 transformers, positioned ...
Cahors
Secondary voltage: 500 kV - 1,100 kV
... superior transformers in different HVDC schemes like HVDC Classic and HVDC Plus. HVDC converter transformers are indispensable, where highly efficient bulk power transmission for offshore and onshore ...
Siemens High-voltage – Power transmission
Output power kVA: 10 kVA - 5,000 kVA
Primary voltage: 34.5, 150, 200 kV
... distribution transformers to support a variety of applications. Our product lines include pole- and pad-mounted, single- and three-phase solutions, as well as primary and secondary substation ...
GE Grid Solutions
Primary voltage: 230 V
Secondary voltage: 115, 230 V
Primary current: 14.2 A - 45.3 A
• Isolating transformers for medical IT systems • Built-in temperature sensor • Shield winding • Insulated mounting brackets • Also available as an energy-efficient variant The transformers of ...
BENDER
Primary voltage: 230 V - 400 V
Secondary voltage: 24 V - 230 V
... thanks to BLOCKIMPEX vacuum impregnation Quick to cable up thanks to the use of spring‑loaded terminals Contact protected screw connection terminals complying with UVV BGV A3 Simple mounting thanks to robust metal footplate ...
Block Transformatoren-Elektronik
Output power kVA: 0 kVA - 20 kVA
► Core type: EI、CD、O、UI… ► Application: Industry PS、Medical PS、UPS… ► Core Material: Silicon Steel (H50、H23、H18、H14、Z11、etc.)、Amorphous.
Electric power: 1 kVA
Single-phase safety isolating transformer Used in connection with Iso D4-Zs (NT689) insulation monitor for a continuous control of the insulation towards ground Primary voltage ...
Primary current: 30 A
Current transformers for energy meters single phase and three phase metering in Residential Metering applications. KEY FEATURES •High Linearity •Low cost •PCB ...
Electrohms
Electric power: 100 kVA
Primary voltage: 36 kV
CQ's Single-Phase Pole Mount Distribution Transformers is a power system used in the United Kingdom and Ireland, where some suburban and rural electricity distribution is done by single-phase ...
CG Power Systems
Primary current: 100, 5 A
Applications Balanced systems: network analyzers, automatic power factor correction systems (PFCs) Features Connection terminal with cover (IP20) for universal connection, no fork needed Bus bar or din rail mounting, included complete ...
ETI
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining