Nominal voltage: 300, 500 V
Temperature: -40 °C - 90 °C
Cross-section: 0.5 mm² - 35 mm²
... protection requirements R 15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3. It is recommended for the internal wiring of rail vehicles acc. to EN 45545-2. fulfils ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 500, 300 V
Temperature: -40 °C - 90 °C
Cross-section: 0.5 mm² - 16 mm²
... protection requirements R 15 (EL1A) acc. to 45545-2 for hazard levels HL1-3. It is recommended for the internal wiring of rail vehicles acc. to EN 45545-2. fulfils fire protection ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 500, 350 V
Temperature: -30 °C - 90 °C
Cross-section: 0.14 mm² - 1.5 mm²
... is a data cable which is flame retardant acc. to UN/ECE R118, self-extinguishing and fulfils fire protection requirements R 15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3 and NFPA ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 350, 500 V
Temperature: -40 °C - 90 °C
Cross-section: 0.14 mm² - 1.5 mm²
... standard and fulfils fire protection requirements R 15 (EL1A) acc. to EN 45545-2 for hazard levels HL1-3. This cable is recommended for the internal wiring of rail vehicles acc. to EN ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 500, 350 V
Temperature: -40 °C - 90 °C
Cross-section: 0.34, 0.25, 0.75, 0.5, 0.14 mm²
... overall copper screen tested acc. to EN 45545-2 Marking for SABIX® R 645 FRNC TP 66450325: SAB BRÖCKSKES · D-VIERSEN · SABIX® R 645 FRNC TP 3 x 2 x 0,25 mm² CE SABIX® R 645 FRNC TP is a paired SABIX® ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 500, 300 V
Temperature: -40 °C - 90 °C
Cross-section: 0.5 mm² - 25 mm²
... R16 (EL1B) acc. to EN 45545-2 for hazard levels HL1-2 flame retardant acc. to UN/ECE R118 Insulation - special Polymer Colour code - black cores with consecutive numbers acc. to EN ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.25 mm² - 35 mm²
... R16 (EL1B) acc. to EN 45545-2 for hazard levels HL1-3 flame retardant acc. to UN/ECE R118 Conductor - tinned copper strands, extra fine wires Insulation - SABIX® X Colour code - black cores with ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 300, 500 V
Temperature: -50 °C - 125 °C
Cross-section: 0.75, 1, 0.5 mm²
... . The flame retardant cable is recommended for the internal wiring of rail vehicles acc. to EN 45545-2. screened, good EMC characteristics good ozone resistance fulfils fire protection ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 500, 300 V
Temperature: -50 °C - 125 °C
Cross-section: 2.5, 1, 1.5, 0.5, 0.75 mm²
... CE SABIX® A 280 FRNC X is a wiring and control cable with good ozone, oil, and chemical resistance. The fire resistant cable is recommended for the internal wiring of rail vehicles acc. to EN ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 30, 600 V
Temperature: -50 °C - 90 °C
... continuously flexible SABIX® USB 2.0 Rail cable acc. to EN 45545-2 Marking for SABIX® USB 2.0 R flex 06019013: SAB BRÖCKSKES · D-VIERSEN · SABIX® USB 2.0 R flex 4x28AWG 0601-9013 USB ...
SAB BROECKSKES GMBH & Co. KG
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining