Nominal voltage: 2,000, 1,500 V
Temperature: 120, 90 °C
Halogen free cross-linked polyolefin photovoltaic cable for the use within PV systems. UL und IEC rated cable for system voltage up to DC 1500 V.

Nominal voltage: 2, 2, 1,500, 1,800, 7 kV
Temperature: -40 °C - 120 °C
Halogen free cross-linked polyolefin photovoltaic cable for the use within PV systems. IEC rated cable for system voltage up to DC 1500 V.

Temperature: -40 °C - 85 °C
Length: 20 m - 500 m
A cable as an antenna: radiating cable for the industry Cranes, elevators or rail-guided vehicles such as overhead monorails: IWLAN RCoax radiating cables enable a reliable radio connection, ...

Temperature: -40 °C - 75 °C
Length: 100 m
... four-wire, industrial PROFINET cabling on the factory floor with special FastConnect cable structure for quick assembly on FC RJ45 and FC M12 plugs. The FastConnect stripping tool enables particularly ...

Preassembled and production-tested installation cables with RJ45 or M12 connection in various lengths from 0.3 m to 50 m. For direct mounting on devices and laying on cable racks with RJ45 or M12 interface ...

Nominal voltage: 600 V - 1,000 V
Temperature: -15 °C - 80 °C
The C1 SH cable is made from highly flexible class 6 plain copper wires that conforms to IEC 60228 standards. It uses nonflammable, flexible special polymer for robotic application ZH. Its conductor has ...
Lapp Muller

Nominal voltage: 1 kV
Temperature: -40 °C - 90 °C
Cold and oil-resistant cables for flexible applications under torsional load, halogen-free - 0.6/1 kV ÖLFLEX® TORSION FRNC: UL: cRUus AWM (II A/B) OIL RES I+II, power + control cable 0.6/1 kV, wind turbine ...

Nominal voltage: 300 V - 1,000 V
Temperature: -55 °C - 145 °C
Cross-section: 1, 1.5 mm²
Electron beam cross-linked cables for more demanding application requirements ÖLFLEX® HEAT 125 C MC - halogen free power and control cable with DNV GL certificate, special fire performance, IEC ...

Nominal voltage: 450, 750, 600, 1,000 V
Temperature: -25 °C - 60 °C
... Permanent tensile load max. 15 N/mm² Minimum bending radius flexing 6x cable Ø fixed installation 4x cable Ø Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC ...

Nominal voltage: 500, 300 V
Temperature: -50 °C - 90 °C
Cross-section: 0.75 mm² - 16 mm²
... control cable with numbered cores Marking for SABIX® A 260 PUR 52600715: SAB BRÖCKSKES · D-VIERSEN · SABIX® A 260 PUR 12 x 1,5 mm² CE SABIX® A 260 PUR is a cold resistant, flexible control cable ...
SAB BROECKSKES GMBH & Co. KG

Nominal voltage: 2,000, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 240 mm²
... control cable with numbered cores for continuous movement Marking for S 200 07741215: SAB BRÖCKSKES · D-VIERSEN · S 200 12 x 1,5 mm² CE High flex cable with numbered cores for continuous movement ...
SAB BROECKSKES GMBH & Co. KG

Nominal voltage: 2,000, 600, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 50 mm²
... PUR control cable with numbered cores Marking for S 980 P 77741807: SAB BRÖCKSKES · D-VIERSEN · 77741812 S 980 P 12 x 0,50 mm² 20 AWG/12c 77742012 UL AWM Style 21060 80°C 600V CSA AWM I/II A/B 80°C 600V FT1 FT2 CE Flexible ...
SAB BROECKSKES GMBH & Co. KG

Nominal voltage: 90 V
Temperature: -25 °C - 80 °C
... /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. NET Price per 1m - Cu included UL-approved PUR-Data Transmission- ...

Nominal voltage: 300 V
Temperature: -30 °C - 105 °C
Cross-section: 0.09 mm²
Flat Ribbon Cable in AWG 28 with spacing 1,27mm, gray with red stripe

Nominal voltage: 300 V
Temperature: -30 °C - 105 °C
Cross-section: 0.09 mm²
Flat Ribbon Cable in AWG 28 spacing 1,27mm, multicolored, color sequence by IEC

Nominal voltage: 450, 600, 750 V
Temperature: 80 °C - 105 °C

Nominal voltage: 600 V
Temperature: 70, 105 °C
Cross-section: 2.11 mm² - 116 mm²
This flexible robot wire uses an ultra-thin conductor. With CE(TUV), UL, and PSE certifications,this cable is highly evaluated for its excellent workability and exceptional flexibility. Electric wire ...

... of the cable jacket: blue • coupling attenuation greater than or equal to 85 dB • electrical data tested up to 1500 MHz • GHMT Cat.7A PVP certified • applicable standards: EN 50173-1, ISO/IEC ...
METZ CONNECT

Temperature: -20 °C - 60 °C
Length: 500, 1,000 m
... • color of the cable jacket: blue • coupling attenuation: 80 dB • applicable standards: EN 50173-1, ISO/IEC 11801, EN 50288-4-1 and IEC 61156-5 • cable jacket: ...
METZ CONNECT

Temperature: -20 °C - 60 °C
Length: 305, 500, 1,000 m
... 40 dB • applicable standards: EN 50173-1, ISO/IEC 11801, EN 50288-6-1, IEC 61156-5, ANSI/TIA-568.2-D • cable jacket: LSHF (LSOH) • flame-retardant to IEC 60332-1, ...
METZ CONNECT

Temperature: -10 °C - 105 °C
Cross-section: 0.75, 0.22, 0.44 mm²
PVC inner and outer providesa good general-purpose cableideal for extension leads. PVC is waterproof and is self-extinguishing, it has a high dielectric strength, good mechanical properties and provides resistance to chemicals, oil, hydrocarbons ...

The SS321 by Temperature Technology Ltd. is a mineral insulated and metal sheathed RTD cable. The unit is available with copper or nickel conductors. It is made out of stainless steel materials SS316 or SS321 sheath. ...

Nominal voltage: 750, 500, 450, 300 V
Temperature: -12 °C - 80 °C
Cross-section: 0.75 mm² - 50 mm²
Carpel flat cable for moving equipment comes in a variety of N° conductors ranging from 6 to 24. The cores are identified according to CEI-UNEL 00722 tables and generally progressive numbering is used, with or without ...

Temperature: -40 °C - 80 °C
Cross-section: 0.14 mm² - 2.5 mm²
STANDARD USE: Cables for control in the machine industry, power tools, appliances. TECHNICAL FEATURES CONDUCTORS Extraflexible stranded bare/tinned copper conductors according to CEI 20-29 cl.6 (IEC ...

Nominal voltage: 50, 300 V
Temperature: -15 °C - 80 °C
Cross-section: 0.25, 0.5, 1.5 mm²
STANDARD USE: Cables for power, control, audio and data TECHNICAL FEATURES CONDUCTORS Stranded tinned copper conductors CEI 20-29 cl.5 (IEC 228), VDE 0295 cl.5 ref. INSULATION Polyvinylchloride ...

Temperature: -40 °C - 90 °C
SOLAR cable means flexible single cables specialty designed for wiring solar plants. SOLAR cables arc extremely robust and resist high mechanical load and abrasion. High temperature ...

Cross-section: 105 mm²
... soil has to be made of StSt (V4A) with a molybdenum content of > 2 % e.g. 1.4571, 1.4404 in accordance with EN 62561-2 and IEC/EN 62305-3, DIN 18014 and DIN VDE 0151.
DEHN + SÖHNE

Nominal voltage: 300, 350 V
Temperature: -5 °C - 80 °C
... 80°C 300 V cable designed for continuous flex applications. The small bending radius permits easy handling and installation in confined areas. very good flexibility small bending radius reinforced outer jacket UR ...
SAB Bröckskes

Nominal voltage: 300, 350, 2,000 V
Temperature: -40 °C - 90 °C
... 300 V cable designed for stressful ultra high speed applications requiring a very small bending radius. The unique design allows this cable to excel in applications where ordinary flexing cables ...
SAB Bröckskes

Nominal voltage: 600 V
Temperature: -40 °C - 70 °C
S 900 is an ultra flexible 600 V UL recognized CSA approved cable designed for power applications. The design incorporates the IEC 60228 class 6 super fine wire stranding which provides ...
SAB Bröckskes

Temperature: -10 °C - 105 °C
... bare copper drain wire Twisted cores & screened construction for reduced electrical noise Conductors PVC insulated and twisted together, aluminium Mylar® tape screen & drain wire, overall PVC ...
Labfacility Limited

Temperature: -75 °C - 260 °C
... offer a PFA Insulated Twin Twisted Thermocouple Cables, PFA Insulated Flat Pair Thermocouple Cables, PTFE Insulated Twin Twisted Pair Thermocouple Cables, and PTFE Insulated Flat Pair ...
Labfacility Limited

Temperature: -75 °C - 260 °C
Single pair PFA insulated cable / wire Laid flat, side by side & PFA sheathed 1/0.315 or 7/0.2mm Conductors Tolerance class 1 Insulation rating -75 to 260°C IEC584 colour coded
Labfacility Limited

Temperature: 105, 125, 150, 180, 200 °C
... according to IEC 61851 for 1-phase and 3-phase charging Charging cables according to NEC Art. 400 and UL/cUL category FFSO (UL62) as well as CSA C22.2 No.49 for 1-phase charging Charging cables ...
LEONI AG

Nominal voltage: 1 kV
Temperature: 20 °C
Cross-section: 10 mm² - 630 mm²
... rigid with a large radius. IEC 60228 Conductors IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) ...
Henan Tong-Da Cable Company

Temperature: -5 °C - 70 °C
We manufacture these products according to the latest national and international standards, with a particular focus on IEC 60502. For power distribution products in the nominal voltage range of 0.6/1 kV to 18/30 kV, we ...

Nominal voltage: 0 kV - 0 kV
... electric wire&cable is used for transmit power(magnetic energy),information and to transform the electromagnetic energy, which is mainly divided into 5 major categories: bare conductor, magnetic wire, power cable, ...

Temperature: -20 °C - 80 °C
This cable is designed for PROFINET and widely used in industrial Ethernet fields, such as machines, equipments, instruments and control panel. Electrical performance according to CAT5e. Suitable for ...
Zhaolong Interconnect

Nominal voltage: 200, 250, 320 kV
Temperature: -30 °C - 60 °C
... manufacturing, FAT and load out etc. The cable system is designed and type tested in laboratory with international recognition as per IEC, ICEA and CIGRE standards etc. For offshore wind farm - ...
ZTT

Nominal voltage: 220 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... insulation 4 insulation shield 5 Semi-conductive buffer layer 6 corrugated aluminum sheath 7 Out sheath IEC 62067 、GB/t 18890 standard :IEC 62067 ,GB/t 18890,also can according to user’s requirements :Instruction ...
Shanghai Morn Electric Equipment Company

Nominal voltage: 1 kV
Temperature: -40 °C - 90 °C
Cross-section: 150, 185, 240, 300, 400 mm²
... Black similar to RAL 9005 Standards Based on HD 604 S1 IEC 60332‑1‑2 Flame retardant IEC 60332‑3‑24 Fire retardant IEC 60754‑1 Halogen free IEC 60754‑2 No ...
Brugg Kabel AG

Temperature: -25 °C - 75 °C
Length: 1,000 m
... data transmission of horizontal cabling system and backbone Category 3 or class A, B or C as defined by the EIA / TIA 568A and ISO / IEC 11801 standard. Cable flame retardant, halogen-free ...
CABLESCOM
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining