- Electricity - Electronics >
- Cable, Connector, Enclosure >
- IEC electrical cable
IEC electrical cables
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Nominal voltage: 600 V - 1,000 V
Temperature: -20 °C - 80 °C
Lapp Muller
Nominal voltage: 2,000, 1,500 V
Temperature: 120, 90 °C
... polyolefin photovoltaic cable for the use within PV systems. Halogen free, low smoke, flexible, single-core, cross-linked double layers photovoltaic cables, in particular for use at direct current (DC) side of photovoltaic ...
Stäubli Electrical Connectors AG
Nominal voltage: 200, 250, 320 kV
Temperature: -30 °C - 60 °C
... manufacturing, FAT and load out etc. The cable system is designed and type tested in laboratory with international recognition as per IEC, ICEA and CIGRE standards etc. For offshore wind farm - Inter array or infield ...
ZTT
Temperature: -30 °C - 70 °C
Cross-section: 25 mm²
... High-voltage-resistant, insulated down conductor for maintaining the separation distance to electrically conductive parts according to IEC/EN 62305-3. Applicable up to an equivalent separation distance s ≤ 90 cm (in air) or s ≤ 180 cm ...
Nominal voltage: 1 kV
Temperature: -40 °C - 90 °C
... Cold and oil-resistant cables for flexible applications under torsional load, halogen-free - 0.6/1 kV ÖLFLEX® TORSION FRNC: UL: cRUus AWM (II A/B) OIL RES I+II, power + control cable 0.6/1 kV, wind turbine drip loop ...
U.I. Lapp GmbH
... joined in the CENELEC. It entails cross-border recognition of the approvals for our cable products in accordance with European / international standards. Single-core cables for regular or IDC contacting with various ...
LEONI Cable Solutions
Nominal voltage: 500, 300 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 185 mm²
... for selected torsion applications conditionally suitable for drag chains versatile use in many industries, particularly in machine and plant construction PVC control and connection cable in alignment with DIN VDE ...
HELUKABEL
Nominal voltage: 0 kV - 500 kV
... The electric wire& cable is used for transmit power(magnetic energy),information and to transform the electromagnetic energy, which is mainly divided into 5 major categories: bare conductor, magnetic wire, power cable, ...
Nominal voltage: 500, 300 V
Temperature: -50 °C - 90 °C
Cross-section: 0.75 mm² - 16 mm²
... D-VIERSEN · SABIX® A 260 PUR 12 x 1,5 mm² CE SABIX® A 260 PUR is a cold resistant, flexible control cable with numbered cores. This oil resistant cable is weather resistant and is recommended for use in automation ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 240 mm²
... control cable with numbered cores for continuous movement Marking for S 200 07741215: SAB BRÖCKSKES · D-VIERSEN · S 200 12 x 1,5 mm² CE High flex cable with numbered cores for continuous movement and uncritical ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 600, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 50 mm²
... PUR control cable with numbered cores Marking for S 980 P 77741807: SAB BRÖCKSKES · D-VIERSEN · 77741812 S 980 P 12 x 0,50 mm² 20 AWG/12c 77742012 UL AWM Style 21060 80°C 600V CSA AWM I/II A/B 80°C 600V FT1 FT2 CE Flexible control ...
SAB BROECKSKES GMBH & Co. KG
... Application : - Earthing and short-circuiting cables. Features : - Conform to IEC 61230. - Material: multi-stranded copper with extra flexible silicone insulation. - Operating temperatures: -40°C to +60°C. - ...
Nominal voltage: 600 V - 1,000 V
Temperature: 0 °C - 90 °C
Cross-section: 1.5 mm² - 35 mm²
... documentation also references
IEC 60502-1.
Operating characteristics
- Long-term operating temperature: ≤ 90°C.
- Short-circuit temperature tolerance: up to 250°C for 5 seconds.
- Cable
Temperature: -10 °C - 105 °C
Cross-section: 0.44, 0.75, 0.22 mm²
PVC inner and outer providesa good general-purpose cableideal for extension leads. PVC is waterproof and is self-extinguishing, it has a high dielectric strength, good mechanical properties and provides resistance to chemicals, oil, hydrocarbons and abrasion. ...
... The SS321 by Temperature Technology Ltd. is a mineral insulated and metal sheathed RTD cable. The unit is available with copper or nickel conductors. It is made out of stainless steel materials SS316 or SS321 sheath. The unit is available ...
Nominal voltage: 600 V
Temperature: -200 °C - 300 °C
... maglev field. Medical equipment MRI signal cables, detection of superconducting magnets and their feeder systems, superconducting solenoid signal cables, ultra-low temperature and high field insulated cables. Advantages ...
Temperature: -25 °C - 80 °C
Length: 100, 1, 500 m
... UL-approved PUR-Data Transmission- /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. number of cores: 2, 4, 6, 8, 12 ...
Metrofunk Kabel-Union
Nominal voltage: 300 V
Temperature: -30 °C - 80 °C
... Control Cable with 7-stranded core 0,09mm² (AWG 28), especially for Insulation-Displacement-Connection (IDC), 1 to 12 pairs, shielded, jacket black number of cores: - 2, 4, 6, 8, 12 ...
Metrofunk Kabel-Union
Nominal voltage: 300 V
Temperature: -30 °C - 80 °C
... Control Cable with 7-stranded core 0,09mm² (AWG 28), especially for Insulation-Displacement-Connection (IDC), 1 to 12 pairs, shielded, jacket black number of cores: - 2, 4, 6, 8, 12 ...
Metrofunk Kabel-Union
Nominal voltage: 750, 500, 450, 300 V
Temperature: -12 °C - 80 °C
Cross-section: 0.75 mm² - 50 mm²
... Carpel flat cable for moving equipment comes in a variety of N° conductors ranging from 6 to 24. The cores are identified according to CEI-UNEL 00722 tables and generally progressive numbering is used, with or without green-yellow conductor ...
Temperature: -30 °C - 60 °C
... CN206672675U) passed 6 pack 1 external interference test. ISO/ IEC 11801-1、ISO/ IEC 11801-2、 IEC 61156-5、 EN 50173-1、EN 50173-2、EN 50288-3-1、 ANSI/TIA-568.2-D、 IEC 60332-1-2、 IEC ...
Zhaolong Interconnect
Nominal voltage: 1 kV
Temperature: 20 °C
Cross-section: 10 mm² - 630 mm²
... rigid with a large radius. IEC 60228 Conductors IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables ...
Henan Tong-Da Cable Company
Nominal voltage: 1 kV
Temperature: -40 °C - 90 °C
Cross-section: 150, 185, 240, 300, 400 mm²
... Black similar to RAL 9005 Standards Based on HD 604 S1 IEC 60332‑1‑2 Flame retardant IEC 60332‑3‑24 Fire retardant IEC 60754‑1 Halogen free IEC 60754‑2 No corrosive gases IEC ...
Brugg Kabel AG
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm²
... conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, self-extinguishing ...
LÜTZE
... SPE cable products, BizLink offers a solution which is standardized according to IEC 61156-x for trailing, torsion and robotic applications as well as special solutions that combine Single Pair Ethernet with various ...
BizLink Robotic Solutions Germany GmbH
Temperature: 70 °C
Cross-section: 1 mm² - 2.5 mm²
Length: 500 m - 1,000 m
... PVC or brown SH jacket + marking + metric Fire resistance NFC 32070.2.1 (flame retardant) and IEC 60332-1 Euroclass B2ca-s1a, d2, a1 (ZPAU - SH cables) Operating temperature: 70°C Resistant to mineral oils, acids ...
Acome
Temperature: -5 °C - 70 °C
... We manufacture these products according to the latest national and international standards, with a particular focus on IEC 60502. For power distribution products in the nominal voltage range of 0.6/1 kV to 18/30 kV, we offer a very wide ...
Nominal voltage: 220 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... insulation 4 insulation shield 5 Semi-conductive buffer layer 6 corrugated aluminum sheath 7 Out sheath IEC 62067 、GB/t 18890 standard : IEC 62067 ,GB/t 18890,also can according to user’s requirements :Instruction ...
Shanghai Morn Electric Equipment Company
Nominal voltage: 300, 500 V
Temperature: -25 °C - 70 °C
... Copper, acc. to IEC 60228. Insulation: PE Polyethylene, acc to EN 50590-2-23 Cabling elements: Pairs or Triads. Core Identification: Numbered tapes applied over screened element. Individual screen: 0,50 sqmm. ...
CABLESCOM
Nominal voltage: 15, 33 kV
... Standards IEC 61089 DIN 48200-6 EN 50182 Application The XLPE covered conductors are used primarily for, but not limited to, overhead secondary distribution lines. Installed on insulators, otherwise treated as ...
Sunway Company
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group