Nominal voltage: 500, 300 V
Temperature: -40 °C - 70 °C
Cross-section: 0.22, 0.5, 1.5, 0.75, 1 mm²
... In this chapter you will find multi-pair compensating and extension cables with PVC insulation for a temperature range up to 70°C. ...
SAB BROECKSKES GMBH & Co. KG
Temperature: 250 °C
Cross-section: 1, 0.22, 0.5 mm²
... The PFA insulated extension cables for thermocouples are used for temperatures up to 250°C. They are available with galvanized as well as with a stainless steel wire armouring. ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 500 V
Temperature: -50 °C - 90 °C
Cross-section: 1 mm² - 2.5 mm²
... ,0 kg/km, cable weight ≈ 307 kg/km - Item no. L09000315: multi-core cable unscreened, 3 x 1,50 mm², largest single wire-ø 0,16 mm, outer-ø ± 10% 6,2 mm, copper figure 43,2 kg/km, cable weight ≈ 64 kg/km - ...
SAB BROECKSKES GMBH & Co. KG
... Extremely flexible SABIX®/PUR data cable with coloured cores and reduced carbon footprint for continuous movement Application: The data cable SABorganic S 1000 Data is suitable for cable chains and ...
SAB BROECKSKES GMBH & Co. KG
... continuously flexible PUR data cable, suitable for robots, robust, oil resistant and flame retardant Application: The SABdynamic 910 Data is a highly flexible data cable that has been specially developed for use in ...
SAB BROECKSKES GMBH & Co. KG
Temperature: -40 °C - 70 °C
Cross-section: 0.75, 0.5, 1.5, 1, 0.22 mm²
... In this chapter you will find compensating & thermocouple extension wires with PVC insulation. They are appropriate for temperatures up to + 70°C. ...
SAB BROECKSKES GMBH & Co. KG
Temperature: 250, 400 °C
Cross-section: 1, 0.22, 0.5 mm²
... Thermocouple Cables for Thermocouples Type J, Type K, Type U, Type E, etc. The cables are halogen-free and especially appropriate for high temperatures up to +250°C or 400°C. ...
SAB BROECKSKES GMBH & Co. KG
Temperature: 250 °C
Cross-section: 0.18 mm²
... This PFA insulated connection cable TGV with fibre-glass braiding and stainless steel wire armouring appropriate for temperatures up to 250°C. ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,200, 1,500 V
Temperature: -40 °C - 250 °C
Cross-section: 0.25 mm² - 6 mm²
... • good EMC characteristics • flexible at low temperatures Conductor - bare copper strands, extra fine wires Core insulation - Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1 Colour code - black and red Stranding - together with ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 1,000 V
Temperature: -50 °C - 90 °C
Cross-section: 35 mm²
... behavior: No fire propagation according to IEC 60332-3-24 + VDE 0482-332-3-24 or IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2. Flame-retardant and self-extinguishing ...
SAB BROECKSKES GMBH & Co. KG
Temperature: -40 °C - 90 °C
... High flame resistance, meeting the requirements of IEC 60332-1& IEC 60332-3-25 Halogen-free, low smoke, low toxicity Acid and alkali resistance, ozone resistance Excellent oil resistance The ...
... FieldLink cable solutions, which, thanks to their robustness, can be deployed in a variety of industrial environments. The Ethernet bus cable range from Cat 5e up to cat 7 is available with twisted pair or with quad ...
Nominal voltage: 300 V - 500 V
Temperature: -30 °C - 70 °C
... HIFLEX-CH SH B2 shielded cables, type LiHCH, are used for analog and digital signal transmission in process and control equipment for applications such as: measuring, weighing, electronics, industrial automation. They can be used in ...
CAE GROUPE
Nominal voltage: 1,500 V
Temperature: -30 °C - 70 °C
... HIFLEX-CH TP SH B2ca shielded multi-pair cables, type LiHCH-TP, are used for analog and digital signal transmission in control process equipment in measuring, control and adjustment technology, for data and signal transmission. The ...
CAE GROUPE
Nominal voltage: 500 V
Temperature: -15 °C - 80 °C
... The CAEINSTRUM® instrumentation cables are used for the transmission of analogue measurement signals in the papermaking, chemical and petrochemical industries. • conform to RoHS • Hydrocarbon resistant acc to NF M87-202 conductor ...
CAE GROUPE
Nominal voltage: 300, 1,500 V
Temperature: -30 °C - 70 °C
... RS485 type data transmission cables, protocol Profibus-DP, with 150Ω impedance. Mixed shielding, aluminium tape + tinned copper braid. CBUSP type cable, compliant with Profibus-DP protocol which uses a RS485 serial ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -30 °C - 70 °C
Length: 100, 500, 1,000 m
... BUS cables intended for building management systems in accordance with EIB/KNX protocol. General shielding with aluminium tape, green LSZH sheath. EIB BUS cable is used for building management systems (detection, lighting, ...
CAE GROUPE
Nominal voltage: 250, 1,500 V
Temperature: -30 °C - 70 °C
Cross-section: 0.22 mm²
... MC-22E cables, cross-section 0,22mm², used for transmission of computer signals, electronic signals, RS232 signalling. Strong signal protection is provided by mixed shielding, aluminium tape and tinned copper braid. Product range - ...
CAE GROUPE
Nominal voltage: 250, 1,500 V
Temperature: -30 °C - 70 °C
... Multi-pair data transmission cables, cross-section 0,22mm², 250V. General mixed shielding with aluminium tape and tinned copper braid, PVC sheath. MCP-22E multi-pair cables, cross-section 0,22mm², used for transmission ...
CAE GROUPE
Nominal voltage: 250, 1,500 V
Temperature: -30 °C - 70 °C
Cross-section: 0.22 mm²
... Multi-pair data transmission cables type RS232 and RS422, cross-section 0,22mm², 250V. Individual shielding with aluminium tape, PVC sheath. MPI-22A multi-pair cables, cross-section 0,22mm², used for transmission of ...
CAE GROUPE
Nominal voltage: 300, 1,500 V
Temperature: -20 °C - 80 °C
... Cable intended for RS485 Modbus signal transmission. General shielding with aluminium tape and tinned copper braid. LSZH sheath. LCAE MPSS 124-120 cable, insulated with PE, low capacitance, is used for control and ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -20 °C - 80 °C
... Low voltage computer cable; signal transmission RS 232 - RS 422 - RS 485 - Modbus • conform to RoHS conductor marerial stranded tinned copper conductor class AWG 24: 7 x 0,20mm core insulation PE Ø: 1.75 mm nominal core identification ...
CAE GROUPE
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group