WAGO digital I/O
* MOS8 8 status outputs (PNP 100 mA) * MOS16 16 status outputs (PNP100 mA)
GF 30% Polyamid 8(12)-32 VDC 1S Li-on Battery -40C +80C 1x IMU Sensor Up to 1 Frequency Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 ...
Makersan
GF 30% Polyamid 8(12)-32 VDC 1S Li-on Battery -40C +80C 1x IMU Sensor Up to 1 Frequency Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 ...
Makersan
GF 30% Polyamid 5(9)-12 VDC -40C +80C 1S Li-on Battery Up to 1 Frequency Input Up to 4 Current Inputs Up to 4 Resistive Inputs Up to 4 High-Side Outputs Up to 4 Low-Side Outputs Up to 1 Analog Output Up to 2 Solid State Relays
Makersan
Expansion connector: 2 PCIe x1 Interface: PCIe x1 gold finger/ PCIe connector (36 pin) (opt.) Security: Security-ROM, Intrusion detection (8 doors) Voltage watcher: Voltage monitoring and warning via MCU
DFI
Port: 1 RJ45/2 RJ45 Interface: PCIe x1 Form Factor: M.2 B-M key 22mm x 42mm (0.87" x 1.65")
DFI
Port: 1 RJ45/2 RJ45 Interface: PCIe x1 Form Factor: M.2 B-M key 22mm x 42mm (0.87" x 1.65")
DFI
>16DI/DO configurable >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
>16DI/DO configurable >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
> 16DO >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
... related systems for high risk industries. The unit can be configured for switch or proximity detector (EN60947-5-6, NAMUR), NO or NC and for NE or ND SPST relay output contact. Each channel enables a Safe Area load to ...
GM International srl
... Available as digital and analogue input and output, thermocouple, and resistance temperature detector (RTDs) modules. All modules are compact in size and will work with Modbus as well as other available protocols. The ...
... remote I/O system, it linked a local area network designed to connect controllers to remote I/O chassis and replacement of discrete wirings by fieldbus or industrial Ethernet communication. MIOS supports ...
... Frequency measurement Pulse width modulation (PWM) Period duration measurement Velocity measurement Digital inputs and outputs Edge time measurement (ETM) Parallel interface Sin/Cos ...
ADDI-DATA
The PA-2000 32 digital output ISA card has 32 digital outputs, 24 V, 3 timers and 1 watchdog. The card has galvanic isolation and is protected against fast transient effects (burst), electrostatic discharge ...
ADDI-DATA
The PA-1000 32 digital input ISA card has 32 digital inputs, 24 V, 14 of which are interruptible. All entries are filtered. 1 channel can be used for monitoring the 24 V supply voltage. The address is ...
ADDI-DATA
... . 2.5 mm² Power LED, green, RxD LED yellow TxD LED, red Digital Input Modul - DI24 BACnet/MS/TP (RS485) Master or slave mode configurable 24 channels digital ...
... connectors, max. 2.5 mm² Power LED, green, RxD LED yellow TxD LED, red Digital input module DI24 MODBUS (RS485) Operating mode: Slave 24 channels digital ...
... extremely high demands on resolution and measuring accuracy. The RTD-P modules have an extremely accurate analogue-to-digital converter and a precision current source for resistance sensors. The modern process-based ...
HiTec Zang GmbH
... Connection type : 3-pin M8 socket • Digital counting function : 32-bit • Frequency measurement : ≤ 100 kHz • For the interrogation of : proximity sensors, switch contacts, fill level switches, pressure switches, digital ...
HiTec Zang GmbH
... (e.g. a solenoid or reflux separator). • 4 active digital outputs • For direct connection of proportional solenoids • LED control display • Short-circuit-proof • Signal : 4 active digital ...
HiTec Zang GmbH
... using Modbus TCP/IP and MQTT. It has a range of input and output options including 6 digital inputs, 2 digital outputs making it suitable for a variety of remote I/O applications. Automatic ...
... is a compact and rapidly to install solution to connect digital and analog signals from the actor and sensor level directly to a control unit in building automation via Modbus RTU protocol. 29 I/Os, some ...
METZ CONNECT
The Modbus module with 4 digital inputs and 2 relay outputs with manual control was developed for decentralized switching tasks. It is suitable for accommodating, for example, light switches and window contacts in a room, ...
METZ CONNECT
The Modbus module in an IP65 housing with 4 digital inputs and 2 relay outputs was developed for decentralized switching tasks. It is suitable for accommodating, for example, light switches and window contacts in a room, ...
METZ CONNECT
ASi-3 Master/Scanner for Allen-Bradley ControlLogix, 2 ASi masters, diagnostic and configuration via RS232 diagnostic interface Technical data Fieldbus interface - ControlLogix ASi-5/ASi-3 - ASi-3 compatible Number of ASi networks, ...
Bihl+Wiedemann GmbH
> Inputs: 16 digital inputs > Temperatures: the correct functionality of the node has been verified in a temperature range between -10° and 60 ° C > Power supply: 24V (10-30V) > Galvanic Isolation: 2000 Vca 50Hz > ...
ELCO Elettronica di A. Ligabue e C. snc
> Inputs: 4 RTD channels (PT100, PT1000, Ni100, Ni1000) > Maximum speed: 38.4 kbps > Distance reachable: 1.2 km > Power supply: 10 ... 30 V > Galvanic isolation: 200 Vac 50 Hz 1min > Communication: RS485 DIMENSIONS > Frontal ...
ELCO Elettronica di A. Ligabue e C. snc
> Inputs: 8 digital inputs > Outputs: 8 digital outputs, PNP type > Temperatures: the correct functionality of the node has been verified in a temperature range between -10° and 60 ° C > Power supply: ...
ELCO Elettronica di A. Ligabue e C. snc
• supply voltage 24V= • 4 outputs SPNO 230V-= max. 5A or transistor (PNP) 24V= max. 800mA or photomos max. 2A • LED indicators for inputs and outputs • 1 potentiometer supply voltage 24V= ±10% power consumption 0,5W ...
HIQUEL
... for the realisation of control systems used in building automation, is an I/O module with 4 digital inputs for dry contact (max 30 Hz) and 4 digital SPDT relay outputs type NC ...
... As an IIoT I/O module, ATOP’s IO5202 Series is a compact solution for connecting digital and analog devices and sensors, enabling you to monitor, acquire and process data from remote ...
Distributed Process Intelligence type, P-NET via Light-Link, RS-485, USB Interface, Dual 100 Mbit Ethernet • Process Automation Controller • Programmable in COPP • P-NET via Light-Link, RS485 and Ethernet • Dual 100 Mbit Ethernet ...
PROCES-DATA A/S
... Energy Exchange Controller CENTRAL UNIT -Processor : STM32 32 bits/200Mhz -Operating system : Free RTOS -I/O coprocessor : FPGA Xilinx -Memories : SDRAM 8Mo, NAND, Crypto. MOUNTING AND INSTALLATION ...
LEROY AUTOMATION
... module and up to 10 I/O modules in a compact mechanical enclosure - Distributed topology In this topology the Controller is integrated by the central system expanded with up to 16 Remote I/Os units ...
The digital input module MV210 has 20 or 32 digital inputs able to connect switch contacts as well as NPN or PNP transistors. To communicate the input data to a controller, an Ethernet port and Modbus ...
akYtec GmbH
The digital input module MV210 has 20 or 32 digital inputs able to connect switch contacts as well as NPN or PNP transistors. To communicate the input data to a controller, an Ethernet port and Modbus ...
akYtec GmbH
The digital input module MV210 has 20 or 32 digital inputs able to connect switch contacts as well as NPN or PNP transistors. To communicate the input data to a controller, an Ethernet port and Modbus ...
akYtec GmbH
... generation and Digital to Analog output modules for providing signal simulation capability The EX1200-1538 is a high-performance multifunction card that provides 8-channels of independent 32-bit counters, 16 channels ...
AMETEK VTI Instruments
The PCH Raw Data Box provides four additional raw data output channels to PCH Engineering’s top-of-the-line vibration monitor, PCH 1420. PCH Raw Data Box is a stand-alone module in PCH Engineering’s modular condition monitoring solution, ...
The ELPRO 115E-2 Ethernet Networking I/O and Gateway is a multiple I/O node that extends communications to sensors and actuators in local, remote, or difficult to reach locations. Designed to work with ...
ELPRO Technologies
... pronounced: "dash one") CANopen module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog mode. Two of the digital ...
Data Panel GmbH
... different I/O signal configurations. It offers a total of 12 inputs, eight of which can be parameterized as analog. The remaining four digital inputs can also be configured as frequency inputs or counters. ...
Data Panel GmbH
... pronounced: "dash one") SAE J1939 module combines many different I/O signal configurations. It offers a total of eight inputs, up to four of which can be parameterized in analog. Two of the digital inputs ...
Data Panel GmbH
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining