An air heater is a heating apparatus used in large industrial and commercial spaces. It takes in ambient air, passes it through a heat exchanger and redistributes it as a function of the configuration of the space and the desired level of comfort.
Air heaters are high-power heaters used to heat large-volume spaces such as industrial buildings, warehouses, workshops, sports arenas, etc.
The three principal types of air heater differ according to their energy source.
- Hot water and steam heaters circulate hot water or steam through a heat exchanger coil.
- In electric models, the exchanger contains a resistance element.
- Gas heaters use a burner to heat the air passing through the exchanger.
Their blowers can be helicoidal or centrifugal.
The range of on-site energy sources and regulations governing the activity in question will determine the choice of heater. A thermal study of the area to be heated, its size and layout will dictate the number, power and flow rate of the heaters.
Multi-function : heating, clothes drying, ventialtion, circulation
The ventilator shall be suitable for ceiling mounting
LCD wireless remote controller
'Auto Heat' ...
Multi-function : heating, clothes drying, ventialtion, circulation
The ventilator shall be suitable for ceiling mounting
'Pre-Heat' function ...
Description
To provide fan assisted heating to commercial or industrial environments, or for drying applications.
Characteristics
* IP24.
...
Description
Designed to heat commercial or industrial environments.
Characteristics
* IP24.
* Made of a paint coated steel sheet.
...
The 233 series heaters are certified by
CSA International to U.S. and Canadian
standards for use in hazardous (classified)
locations. ...
The enclosure heaters avoid condensation in compact enclosures and provide a minimum temperature.
+ Efficient
+ ...
The compact convection heater prevents condensation and temperature fluctuations in explosion ...
The small heaters avoid condensation in compact housings and can provide a minimum temperature.
+ ...
Anticondensation Heaters
High performance and fast mounting
Application
Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures or high humidity ...
Anticondensation Heaters
High performance and fast mounting
Application
Enclosure heaters are often necessary to prevent failures or corrosion caused by low temperatures or high humidity ...
With a double objective:
To prevent the formation of condensation inside the enclosure.
To reheat the electrical ...
Electric Heater
Application
Protect mechanical, electrical and electronic equipment from low temperatures, condensation and corrosion with this thermostatically controlled, fan-driven ...
Hot gas generators fabricated by Unitherm Cemcon are designed for direct air heating performed by a firing system. Air to be heated is either supplied by ...
General:
* Eliptic combustion chamber in stainless steel AISI 430.
* Bag type heat exchanger, in stainless steell AISI 430.
* Fumes box and shaft outlet in stainless steel AISI 430.
* Double thermostat with safety ...
Heat generated by electrical equipment operating under load will prevent the accumulation of condensation. After the equipment has been switched off ...
Adopting latest technological development, we manufacture a precision engineered range of spin flash dryers which are used for drying of wet cake, viscous and thick ...
Airheater capacities available from 35.6 to 239.8 kW.
Versatile ...
Direct fired gas heating.
Low ...
Features
Air temperatures to 1600°F (871°C)
Quartz outer tube housing.
Nozzled (Style B) or open-ended ...
Mechanical motors have been decreased in size to reduce the ...
EOLO - HEOLO - EOLOmini
Cooling-only and heat pump air-cooled ...
TAEevo HAEevo
Air-cooled heat pumps.
Cooling capacity 1,4 - 186 kW, heating capacity 12 - 86,7 kW.
Technological innovation, absolute reliability and customer satisfaction have been MTA's hallmarks in over 25 years ...
ORION
Chillers with centrifugal fans, heat pumps, with hermetic scroll compressors.
Cooling capacity from 17 to 67 kW.
The Orion range of chillers and reversible heat pumps, featuring centrifugal fans, offer either single or, above 50 kW, tandem scroll compressors. ...
Hitachi compressors, together with DC inverter PAM technology, aid the achievement of a system power factor of almost 100%, providing unparalleled performance ...
The Hitachi Multizone range was the world's first all DC Inverter Multisplit system with zone by zone cooling or heating for up to six rooms. Hitachi DC scroll and DC twin-rotary compressor, together with award-winning DC inverter PAM technology, ...
Up to 16kW capacity is available from single fan unit (800mm high) or 28kW in a low height ...
GEA HeaMo AIR is the air-cooled system version for outdoor installation, to employ outside air as source of energy for exclusively cold or hot water operations. For strictly cold-water operation, the air-cooled Cu-Al heat exchanger is used as a condenser, ...
Lanemark FD-E series packaged burners are designed to offer low cost, high turn-down (gas only) control for process air heating applications in convection ovens and dryers.
Lanemark FD-C series packaged burners are specifically ...
The requirement for maximum combustion efficiency with minimum emissions can be fulfilled with the Lanemark FD-C (GA) burner series, which is ideal for direct fired operations. Units ...
Offering flexible, high turndown (gas only) control for process air heating applications and convection ovens and dryers, the Lanemark FD-C series of packaged burners is available across a wide heat input range from 117 kW to 880 ...