- Industrial machines and equipment >
- Heat Exchanger and Refrigeration >
- Air/water heat exchanger
Air/water heat exchangers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Power: 1.2, 0.65, 1, 0.6 kW
Air/water heat exchanger for hygienically sensitive production zones in the food and consumables industry – the optimum addition to the Rittal Hygienic Design range. ...
RITTAL
Power: 375 W - 5,000 W
Output classes 375 – 5,000 W. For use in tough environments. Convenient mounting options and flexible water connection options. Partial or full internal mounting possible.
RITTAL
Power: 1,875 W - 4,000 W
Output classes 1,875 – 4,000 W. For use in tough environments. Flexible water connection options.
RITTAL
... glycol heat exchanger from technotrans are used in various systems. For example, in free cooling: the heat exchanger transfers the waste heat from the ...
Power: 870 W - 25,000 W
Operating pressure: 5, 0.02, 10, 0.3 bar
Temperature: 10 °C - 50 °C
... the offer. Control EXW wall-mounted water/air heat exchangers can be equipped with a mechanical thermostat and solenoid valve to control the water ...
Power: 4 kW - 900 kW
Operating pressure: 35 bar
Temperature: 200 °C
Highly efficient heat transfer solutions for cooling marine, land-based and underground hydraulic systems. Bowman is a leading UK manufacturer of hydraulic oil coolers that deliver highly efficient cooling solutions ...
Bowman
Bar and Plate Heat Exchangers API Heat Transfer's line of Airtech and Covrad air cooled all-aluminum brazed bar and plate heat exchangers ...
API Schmidt-Bretten, API Heat Transfer group
Copper-Brass Radiators Our durable and versatile line of copper-brass heat exchanger technology can be applied to any set of operating conditions and is available in a wide range of sizes and types. BOLTED ...
API Schmidt-Bretten, API Heat Transfer group
Power: 0.75 kW - 7.46 kW
Operating pressure: 5 psi - 2,000 psi
Temperature: 56, 93, 150, 121 °C
... brand offers a full line of process cooling heat exchangers. Water-Cooled Fixed bundle shell and tube U-Tube Removable Bundle Stainless Steel brazed plate Large ...
API Schmidt-Bretten, API Heat Transfer group
Power: 10 kW
Temperature: 1 °C - 70 °C
... temperature monitoring with alarm contact The PWS 7702/PWS 7702 SL Series of Water/Air Heat Exchanger, manufactured by PFANNENBERG, is specifically designed for enclosure ...
PFANNENBERG
These exchangers allow to release heat from electrical cabinet when cold water is available (tap water, network water or tower water). They ...
Power: 6 W
Temperature: 50 °C
... concurrently. The dispelled moisture and fresh air undergo ample heat exchange in the waste heat regeneration device, allowing for the discharge of moisture and the introduction of fresh ...
Power: 3,900 W - 6,000 W
Temperature: 10, 15, 20, 25 °C
Cooling power : from 3900 to 6000 W(WI 0/L35 according to DIN 3168). To be fixed either on the front door or side panel ofa cabinet. Factory pre-set to achieve an average cabinet tem-perature of 350C max.
Operating pressure: 35 bar
Temperature: 350 °C
S-TYPE HEAT EXCHANGER Multi-purpose condenser U plates Exchange area up to 500 m² in one unit Materials Stainless Steel Duplex, Super-Duplex Nickel Alloys Titanium
The DTI type heat exchanger is a double tube heat exchanger (tube within a tube). The inner tube is corrugated for increasing the heat transfer. The ...
The product uses ambient air as the cooling medium to cool or condense the high-temperature process fluid in the tube. Features Air coolers use air as a cooling medium to save water ...
... various fields of social development,for which, the cooling of engines and hydraulic system is especially important. For heat exchanger used in construction machinery, the vibration protection, sand blocking ...
www.fscoolers.com
Power: 2,000 W - 440,000 W
Temperature: 30 °C
... closed-loop clean-water system and you can do this with one of the Ambrell water to air heat exchangers sized for your induction heating system. Water-to-Water ...
... unused heat energy. Thus heat exchangers protect resources and increase the efficiency of all systems. This results in substantial savings, at least in part, of energy costs. The use ...
... plate heat exchangers are ideally suited for media containing solids and pulp. With their low investment and operating costs these are a viable alternative to shell-and-tube and spiral heat ...
GEA Polacel Cooling Towers bv
Power: 1,080 W - 7,133 W
Operating pressure: 0.5 bar - 3.5 bar
Temperature: 10 °C - 60 °C
Water is conveyed into the heat exchanger and cooled by the fan-forced air. The heat exchange occurs between the ambient air and the ...
Power: 2,500 W - 15,000 W
Temperature: 20 °C - 60 °C
... conditions • No routine maintenance like changing of filters or cleaning of exchangers necessary • Vertical mounted excahngers BLU, cooling capacity 1750 - 15000 W • Roof mounted exchangers BIT, cooling ...
Operating pressure: 20,000 Pa - 30,000 Pa
... thermal performance. Two combined heat exchangers, consisting of both the air to air heat recovery and air to refrigerant. Integrated ...
Operating pressure: 10 bar
Temperature: 184 °C
The multitube mixflo heat exchanger has small diameter tubes that are fitted inside an external jacket. These are welded from one end to the other. The product that needs to be thermally processed will ...
COMBIAERATOR ® EXCHANGER (PATENTED) - Exchanger/refiner/homogenizer for aimed technological needs of fast crystallization and high aeration. - The number of items mounted on the hygienic design frame, ...
Operating pressure: 129 Pa
Temperature: 34 °F - 140 °F
... are extreme, Hydro Edge Air-to-Water Heat Exchangers by Thermal Edge provide reliable, efficient, and cost-effective solutions. Ideal for high ambient conditions and ...
... refrigerant the supply air can be cooled up to 12 K. In addition to this the integrated plate heat exchanger is used for heat recovery in winter. Softcool®’s optimized ...
Polybloc AG
Frigosystem's KBFC Series is part of the company's line of refrigeration systems. Models of the series are capable of integrating with the chiller models of the RACA/C or RACA PLUS ENERGY series. Integration is achieved via high-quality ...
Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining