- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Optical data cable
Optical data cables
Optical cables of the OPTs type with a built-in supporting element are designed for suspension and operation on supports of overhead communication lines, urban electric transport and overhead power transmission ...
Ipcom
Optical cables of the OPTs type with a built-in supporting element are designed for suspension and operation on supports of overhead communication lines, urban electric transport and overhead power transmission ...
Ipcom
Optical cables of the OPTs type with a built-in supporting element are designed for suspension and operation on supports of overhead communication lines, urban electric transport and overhead power transmission ...
Ipcom
... -to-the-desk, e.g. optical fibre cables in horizontal networks. The decision to use either fibre optic or copper data cables as an ideal solution for horizontal networks ...
Prysmian Group
Industrial Ethernet optical fibre data cables for tough industrial environments. Prysmian Group industrial optical fibre data cables ...
Prysmian Group
Nominal voltage: 75 V
Temperature: -30 °C - 70 °C
Draka branded automation and control cables for advanced office and factory networks support the latest ERP, process control and automation solutions, and the new generation of TCP/IP-based industrial applications. They ...
Prysmian Group
Temperature: -40 °C - 70 °C
... Universal fibre optic cable with multiple optical fibres in a loose tube, reinforced, flame retardant (a) CENTRAL STRENGTH MEMBER: dielectric FRP rod with or without PE jacket, (b) TUBE: loose tube ...
DLL Partners
Temperature: -25 °C - 70 °C
Light, thin and rugged indoor cable for use as a patch cable in distribution systems, as connection cable for terminals as well as for workstation cabling. For direct connector assembly.
DLL Partners
Temperature: -25 °C - 70 °C
DLL Partners
Temperature: -40 °C - 125 °C
... desired network behavior of several communication objects into a device. Proven Network Cables for ODVA™ DeviceNet™. NWI leads the way manufacturing rugged DeviceNet™ cable specifically designed for ...
... Northwire GEV-1000 cable has passed 12 million flex cycles when tested on the Northwire standardized tick-tock testing apparatus. For details on flex testing go to about continuous-flex cable. * UL ...
Rugged Bus Cables for Industrial Networks Northwire leads the way manufacturing rugged cables specifically designed for the tough plant environments utilizing networked discrete automation and control. ...
... characteristics RISER micromodule cables are designed for FTTH system rising column cabling in buildings. They provide the subscriber connections at the floor distribution box. Advantages • ...
Temperature: -40 °C - 70 °C
... aerial Design and Test Criteria - ANSI/ICEA S-87-640 Corning recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation ...
CORNING
Temperature: -20 °C - 70 °C
Length: 10, 5 m
The more robust alternative to standard duplex patch cables Flexible and compact. Crush and kink resistant. Twice as strong as standard duplex patch cables. Less prone to damage during and after ...
Black Box
Temperature: -55 °C - 125 °C
This family of two different single-mode fibers is specifically designed for non-traditional data and telecom applications that use standard telecom wavelengths. Tactical fiber survives and transmits light even under ...
Nufern
Nominal voltage: 0 V - 4 V
Temperature: 0 °C - 70 °C
... 850 nm. The electrical interface uses a 38 contact edge type connector. The optical interface uses a 12 fiber MTP(MPO) connector. Four-channel full-duplex active optical cable with ...
T&S Communications
Category 7A twisted pair ethernet cable is used to connect network devices such as Ethernet hub, router, and network switch. The bandwidth of Cat 7A network cable is up to 1000 MHz and also provide positive ...
CRXCONEC
Temperature: -5 °C - 80 °C
Communication between transmitter and receiver Logical state of 0 and 1 control Signal for turning on and off/start and stop Outer jacket valley-sealed extruded and high abrasion resistant Oil-resistant UV-resistant Ozone-resistant Silicone-free CFC-free REACH/ROHS ...
TSUBAKI KABELSCHLEPP
Nominal voltage: 3 V
Temperature: 0 °C - 70 °C
Length: 20 m
active optical cables are designed for use in 400 Gigabit Ethernet links on up to 20m of multi mode fiber. They are compliant with the QSFP-DD MSA and IEEE 802.3cm/cd.The optical transceiver ...
Accelink Technologies Company
Temperature: -40 °C - 85 °C
Length: 300 m - 750 m
Glass optical fibers are used indoors and outdoors to build optical network structures with a large extension. The different cable variants for fixed or moving applications are offered ...
Siemens Industrial Communication
Nominal voltage: 0 V - 330,000 V
Temperature: -40 °C - 70 °C
... capacity over 2,500,000 kilometers, as a world-class specialist for special optical cable, ZTT could provide the best products and service to satisfy every customer. ZTT fiber optic ...
ZTT
DIAMOND’s FAN-OUT Assemblies cabling system is an easy and secure solution to perform fiber optic installations with no need for expensive tools and equipment.The fan-out trunk cable ...
The MTP Back-Bone cable is pre-terminated and pre-tested ensuring the highest performance. The MTP Connector is the low loss Elite® Connector from US Conec and is compatible with all RapidNet MTP Cassettes. The MTP Back-Bone ...
Temperature: -100 °F - 350 °F
The sub-miniature coaxial cable assembly is what the Endevco model 3003C is. It is designed for usage with Endevco accelerometer models 22 and 23. Along with every transducer, the model 3003C 6 inch cable ...
Endevco
Nominal voltage: 200 V
Temperature: -200 °C - 180 °C
... demand reliable data transmission, GORE Space Cables for SpaceWire applications deliver — providing bidirectional, high-speed data transmission for satellites, telescopes observatories ...
Temperature: -40 °C - 300 °C
Fiber optic temperature sensing cable, extra small, armored with stainless steel loose tube, stainless steel strength members, fast thermal response, for 1 to 4 polyimide coated optical ...
Brugg Kabel AG
... loose-tube cables up to 144 fibers with stepped standard connector legs at both sides inside robust tensile and crush resistant installation tubes suitable for OSI PreCONNECT®-HIGH DENSITY module panel. FO-cable ...
Rosenberger OSI
Nominal voltage: 50 V
The ExaMAX® I/O system offers cable assemblies and I/O connector solutions for both internal and external applications. ExaMAX® I/O products are capable of delivering high speed performance of 25 Gb/s ...
Nominal voltage: 600, 1,000 V
Temperature: -35 °C - 90 °C
Cross-section: 1.5, 2.5 mm²
... speed operations and for multiple cable deflection in the process of cable payout. The product is a reeling cable which is flexible in nature. Its other applications include level wind ...
Nominal voltage: 300 V
Temperature: -5 °C - 80 °C
Conductor: High-flexible class 6 complying with: VDE 0295, IEC 60228 Insulation: TPE Core ident.: colour complyng with DIN 47100 Core assembling: special multi-ply with soft strip on outer layer Jacket material: special compound type ...
Brevetti Stendalto
Category 5e, industrial (CM), 4-pair, F/UTP copper cable; stranded copper conductors are 26/7 AWG with HDPE insulation. Conductors are twisted in pairs, surrounded by an overall metallic foil and a PVC jacket. ISFCH5C02ABL-XG Category ...
PANDUIT
Nominal voltage: 300 V
Temperature: -20 °C - 70 °C
This cable has an electrical resistance section of .60: 200MOhm x km at 20°C. Its design meets multiple CEI and IEC standards. The fixed laying temperature range is -20 to +70°C. The accessory has an inductance of <0.9mH/km ...
Pavone sistemi
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining