Protection relays
Trigger voltage: 28, 250 V
... pole motor protection controls with automatic reset actuation, small physical size, reliable snap-action mechanism. Caution: In specifying these 2 products, care should be taken to ensure that automatic motor re-start ...
E-T-A
Tripping current: 5 A - 30 A
... Great accuracy Full reliability Phase unbalance protection Direct mount to IEC contactors Panel mount adapter for NEMA contactors Interchangeable with thermal overload relay ...
... and software, accompanies it. The relay is integrated with IDMT function. The relay are extremely safe and can provide quick protection against one or both over current & earth elements ...
CG Power Systems
Tripping current: 0.5 A
Trigger voltage: 24 V
The LC 200 accessories electronic overload guard features a power supply that ranges from 12 to 24V AC or DC. It consists of a red LED six-digit display placed on the top of the device. It mounts on a DIN rail and uses a 5.08 plug-in ...
Pavone sistemi
Trigger voltage: 24, 240 V
... level Imax, the protector will trip and the red LED will illuminate indicating the fault condition. During the time delay period the red LED will flash for the set time (t) before the relay energises ...
Crompton Instruments
Tripping current: 4, 10 A
Trigger voltage: 24 V
... common circuitry. Single channel versions available if required, to provide single loop integrity on Emergency Shut Down and Fire & Gas applications. Configuration components are easily accessed by removing cover. DIP ...
GM International srl
Tripping current: 0.12 A - 55 A
... important to prevent the motor from overheating, or thermal overload. IMO Thermal Overload Relays offer electromechanical protection for main circuits and reliable protection for motors ...
IMO Precision Controls Limited
Trigger voltage: 230 V
Tripping current: 63 A
Trigger voltage: 275, 175 V
... under voltage protective device considered modular design. The circuit board adopted good quality Latching relays and others components with reliable performance. When the power supply is unstable (voltage ...
Yueqing RunEasy Electronic Technology Co.,Ltd.
Trigger voltage: 110, 208, 380, 400, 415 V
... phase loss - Adjustable Trip levels and Time delay - SPDT Relay output - 17.5mm wide, DIN Rail mount - UL Listed The product monitors it’s own three-phase supply and for the output relay to energise, ...
Broyce Control
Group safety relay class level 4, allows you to connect the barriers Red Beam to the actuator final, thus providing an additional level of protection. Conformity: - 2006/42/EC Machinery ...
Hesisafety
Tripping current: 15 A
Trigger voltage: 250 V
... unique sensitivity to currentsbelow one amp (1 A) allows more flexible motor design solutions, as well as placement of the protector outside ofthe motor windings, in more accessible and serviceable locations.Available ...
Electrica s.r.l.
NPP series Multifunctional anti-electric protection device. Product Features: 1. Prevent electric shock; children will not get electric shock when inserting metal conductor into socket unconsciously. 2. Prevents ...
... rectified before it is fed into a comparator. If the current is greater than a set detection level, then a fault is signalled via relay contacts. The fault output may reset after a delay if residual current falls below ...
Tripping current: 16 A
Trigger voltage: 250 V
... switches. While "normal" relays are monostable, i.e. they return to the idle state when the excitation is switched off, remanence relays are bistable, i.e. the current switching state is retained irrespective ...
Releco
Tripping current: 0.11 A - 11.5 A
... pushbutton : Trip reset ■ Blue pushbutton : Stop and manual Reset ■ Yellow trip flag indicator : overload relay tripped ■ Protection by fuses or by magnetic circuit-breaker type GV2-L, ...
... records; ● Powerful graphic programmable Logic. Rich protection functions Feeder protection; Transformer protection; Motor protection; Capacitor protection; ...
Tripping current: 0.6 A - 25 A
Trigger voltage: 115 V
T motor protector is designed to protect single phase induction motors against overload and locked rotor conditions up to 65AI • AUTOMATIC RESET: Main application is protection of hermetic compressor ...
Tripping current: 11.5 A
... Features • Rated current up to 630 A at 600 Vac, 50/60 Hz • Overload protection trip Class 10 A • Phase loss sensitivity • Adjustable current setting for overload protection • Automatic or manual ...
Multifunction protection relay used to provide additional generator protections in more demanding applications, such as medium or high voltage plants, or oil & gas installations. D-PRO ...
S.I.C.E.S.
... Five zone phase-to-phase distance protection (21P) • One zone phase-to-phase distance protection for pilot scheme (85) • Five zone phase-to-ground distance protection (21G) • One zone ...
NR Electric
Trigger voltage: 0 V - 150 V
... even posing a threat to personal safety. This CT secondary overvoltage protector offers protection from such accidental damage caused by secondary transient voltage. • Protection for ...
... fault recording • 64 sample for cycle measurement for accuracy of protection element COMMUNICATION SECURITY Communication Security through redundancy protocol and Cyber Security ...
THYTRONIC
... one-box solutions for protection and control, which allow protection of primary equipment by simultaneously accomplishing control and monitoring functions in electric power systems. The overcurrent-time ...
Sprecher Automation
Tripping current: 5 A
Protection relay against overload, underload, and phase loss. With display. Codes and references - 10002217 TPM5-230 - 10002218 TPM5-400 - 10002451 TPM5/5-230 - 10002452 TPM5/5-400 Specifications - ...
Toscano Linea Electronica
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining