Temperature: -45 °C - 700 °C
... dry-block calibrator, the sensor size (diameter and length) and the difference between calibration temperature and ambient temperature, create an axial gradient deviation inside the insert. ...
Temperature: -50 °C - 400 °C
Resistance thermometers SCR200 are designed for fitting directly into drilled hole or into process. SCR200 consists of thermometric resistor, protection tube made out of stainless steel and connection cable. Application areas: - fine ...
SIMEX Sp. z o.o.
Temperature: -40 °C - 400 °C
Probe diameter: 4, 6, 5 mm
... class Sheath: length min. 15 mm - diameter 4 mm - diameter 6 mm - diameter 5 mm stainless steel 1.4541 Operating temperature: max. 400°C
SIMEX Sp. z o.o.
Temperature: -50 °C - 400 °C
... out of stainless steel and connection cable. Insertion length, thermowell diameter, process connection thread, number of sensors, accuracy, cable length and insulation can be selected individually for the respective ...
SIMEX Sp. z o.o.
Temperature: -45 °C - 700 °C
... dry-block calibrator, the sensor size (diameter and length) and the difference between calibration temperature and ambient temperature, create an axial gradient deviation inside the insert. ...
Temperature: -35 °C - 85 °C
The long-range wireless sensor LoRa® SPY T0 measures and records temperature during Transportation Robust and waterproof, the LoRa SPY T0 is designed to the cold chain monitoring during transportation ...
Temperature: -30 °C - 70 °C
... data transmission module. In case of threshold excursions, real-time alerts are sent. Temperature measurements are managed on the JRI MySirius temperature monitoring web application. BENEFITS • ...
Temperature: -30 °C - 70 °C
... data transmission module. In case of threshold excursions, real-time alerts are sent. Temperature measurements are managed on the JRI MySirius temperature monitoring web application. BENEFITS • ...
Temperature: 0 °C - 160 °C
Probe diameter: 9 mm
Duct temperature sensor Measuring impedance Pt100 according to DIN EN 60751 Available as duct, room, outdoor and contact sensors Resistance thermometer for temperature ...
Temperature: 0 °C - 50 °C
Probe diameter: 9 mm
Room temperature sensor Measuring impedance Pt100 according to DIN EN 60751 Room temperature sensor RF1 for dry rooms, ...
Temperature: 0 °C - 200 °C
Probe diameter: 9 mm
temperature sensor Measuring resistor Pt100 according to DIN EN 60751 Available as duct, room, outdoor and contact sensors Contact temperature sensor ...
Temperature: -30 °C - 60 °C
The STR temperature sensor are designed in a modern housing measures the temperature from -30 up to +60°C . The range is available with all type of current sensor elements ...
Temperature: -50 °C - 100 °C
Room sensor: P/N. 31055-01 PT 100 ohm at 0°C class B sensing element inside a holed plastic box to IP 20, for wall mounting. Electrical connection by a 2, 3 or 4 poles terminal block through the bulkhead. Outside ...
Temperature: -50 °C - 105 °C
NTC temperature probe -50°..+105°C, S=5x20mm, cable L=3m, waterproof, no connector Characteristics • Product type: Probe • Probe type: NTC-Probe • Typical application area: Freezer, refrigerator, ...
ELPRO-BUCHS AG
Temperature: -70 °C - 260 °C
Pt100 4-wire temperature probe, Temperature range -90 °C..+260 °C, DIN A: -70 °C..+260 °C, cable length 4m Characteristics • Product type: Probe • Probe type: Pt100-Probe • Typical application ...
ELPRO-BUCHS AG
Temperature: -200 °C - 500 °C
Pt100 4-wire ML-temperature probe, Ø 3 L= 350 mm, Temperature range -200 °C..+500 °C, class A -30 °C..+300 °C otherwise class B, bendable, silicon cable L=5m, without connector. Supplied label that can ...
ELPRO-BUCHS AG
Temperature: -30 °C - 60 °C
An indoor sensor in modern housing design measures the temperature in the range of -30 up to +60°C in gasiform medium. The temperature probe can be mounted directly on-wall ...
Temperature: -30 °C - 75 °C
A radiation sensor in modern housing design measures the thermal radiation in the range of -30 up to +75°C in gasiform medium. The temperature probe can be mounted directly ...
RELIABLE INDOOR TEMPERATURE MEASUREMENT Room temperature probes are very important in order for room temperature dependent heating ...
... surface temperature measurements on pipes such as the flow and return in heating systems. Correctly adjusted flow and return temperatures are elementary for the efficiency of the entire ...
... MOISTURE, ICE, WATER, TEMPERATURE CHANGES AND VIBRATION Air conditioning probes measure the flow and return temperatures in the refrigeration and heating cycles of the air conditioning ...
Temperature: -30 °C - 100 °C
Features: • Thermopile Temperature Sensor • TO-46 Package • High Sensitivity • 5.5 μm LWP Filter • High Accuracy NTC Applications: • Non-contact Temperature Measurements • Forehead ...
Shenzhen MemsFrontier Electronics Co., Ltd.
Sensor NTC Room temperature probe 100K Ohm. Room installation (wall mounting).
Seitron SpA
Temperature: -70 °C - 600 °C
... Standard measuring temperatures are -70 ° C. .. +300 ° C; High temperature versions +500 ° C / +600 ° C, low-temperature versions, special materials, special process connections and OEM ...
Temperature: -35 °C - 70 °C
Surface mounted room sensor for temperature measuring. For set point and fan stage adjustment, manual override for room and office applications please refer to 'Room ...
Thermokon Sensortechnik
Temperature: -30 °C - 55 °C
Internal wall mounted wireless temperature transmitter with on board temperature sensor. This sensor is housed in a modern, attractive wall mount enclosure and has an ...
Temperature: 0 °C - 40 °C
In HVAC plants to acquire the room temperature. For use with controllers whose sensor signal input are not galvanically separated from the AC 230 V mains. The sensor ...
Temperature: -40 °C - 200 °C
Ptse temperature sensor • Pt100 sensor • Extension cable 3 wires with shield • Standard cable length: 2,5 mt (different lenghts on request) Technical details • Pick-up range: from ...
Temperature: -55 °C - 125 °C
Probe diameter: 6 mm
T119 digital temperature sensor converts physical temperature to digital output,which can better support the temperature control. To meet requests of different customers, ...
Soway Tech Limited
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining