- Electricity - Electronics >
- Switch and Relay >
- Safety contactor
Safety contactors
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 15 A - 200 A
Load voltage: 24 V - 600 V
Our Bulletin 502L Combination Lighting Contactors with Disconnect Switch combine switching and over-current protection in the same enclosure. These contactors consist of a Bulletin 500L ...
Allen Bradley
Primary current: 150, 12, 65, 32 A
Load voltage: 24 V - 240 V
The DILMS safety contactors of the Eaton Moeller series offer reliable switching in safety-related applications, to make your machines and systems even safer. All versions of the DILMS ...
Primary current: 9 A - 80 A
Load voltage: 24, 220, 440 V
The WEG line of contactors for safety applications (CWBS line 9 A up to 80 A in AC-3), has been developed in accordance with IEC and UL standards, have mechanically linked contacts (IEC / EN 60947-5-1) ...
... devices can be configured as NO/NC contactor, disconnector or changeover switch. This enables us to react flexibly to changing customer requirements. Features Innovative Design Easily configurable as NO/NC contactor, ...
Primary current: 8 A
Load voltage: 250 V
... performance: PL = e Safety category: 4 Safety Integrity Level: SIL 3 Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening ...
Primary current: max 400.0 A
Load voltage: 12 V - 24 V
BSBC7 Series DC high voltage contactor are used in 12VDC~1000VDC, rated current up to 250A, Max.continuous carrying current up to 500A. It is widespread used in electric vehicle and battery charging system, wind power ...
Primary current: 1 A - 500 A
Load voltage: 12 V - 1,000 V
Strong control load capacity: rated operational voltage 12VDC~1000VDC, rated operational current 500A. Safe: Full sealed with epoxy resin, contact and coil will not be oxidized, product performance is not affected by external environment, ...
Primary current: 25 A
Load voltage: 600, 220, 380, 415, 440 V
GSC1-09/3-150/3 Series 3P AC Contactor For remote connection and disconnect circuit, and can be combined with the appropriate thermal overload relay to form an electromagnetic starter, in order to protect the possible ...
Tianshui 213 Electrical Apparatus Group CO.,LTD.
Primary current: 0 A - 63 A
... reliable and effective product? Our Installation contactors excel in silent operation and are distinguished by low coil consumption. In electronic system they provide reliable, safe and efficient management ...
Iskra d.d.
Primary current: 9 A - 170 A
Load voltage: 0 V - 690 V
The UEC1-09C...170C AC contactors range to a rated current of 9...170A under the utilization category AC-3 and can be driven by both 50Hz and 60Hz. They can be combined with a thermal overload relay. Product Features - ...
Primary current: 1,300 A - 1,500 A
Load voltage: 900 V - 1,800 V
... plants electrical equipment designers count on our contactor solutions for reliable performance. Our BMS, SEC, and HS contactors can be configured to meet a wide variety of needs, including line contactors, ...
Primary current: 32 A
Load voltage: 230 V
- Rated operating voltage of power contactors: up to 690V; 50/60Hz - Surge voltage wear resistance: >8000V - Rated operating voltage of the coil: 12/24/36/48/110/230/400 - Electrical wear resistance (number of cycles): ...
Elmark
Primary current: 20 A - 110 A
Load voltage: 110 V - 660 V
... produced by operation. Contactor can also be attached with building block type auxiliary contact group, air delay contact, mechanical interlock mechanism, etc. accessories, to be composed into delay contactor, ...
... overcurrent trigger providing cut-out protection (safety feature). 1~ motor contactors monitor one connected motor each (TP thermostatic switch). The monitoring device for the temperature ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining