- Electricity - Electronics >
- Switch and Relay >
- Power contactor
Power contactors
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 200 A - 600 A
Load voltage: 0 V - 85 V
... Overview
Power relay 200A, 400A and 600A intended for
electric vehicle applications to isolate the control circuit from the
power circuit. Ideal as a main cutoff on an
electric ...
Primary current: 0 A - 1,000 A
Load voltage: 0 V - 1,500 V
... the HVC50, a high-voltage DC contactor designed for connecting or disconnecting lithium-ion battery systems up to 1500 V for traction, energy storage systems (ESS) and megawatt charging systems (MCS). The HVC50 provides ...
TDK Electronics Europe
Primary current: 40 A
Load voltage: 440 V
... Multi-pole Power Relay for Contactor Current Range Capable of Carrying and Switching 40 A at 440 VAC • One pole carries 40 A. UL NO contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations). EN 60947-4-1 NO contacts ...
Primary current: 450 A
Load voltage: 7.2 V - 15 V
... transfer stations Electric furnaces Data centers Wind power plants Photovoltaic panels Siemens 3TM vacuum contactors are available in several versions, including: Contactor 3TM1: ...
Primary current: 16, 20, 11.5 A
Load voltage: 230 V
... additional protection against electric shock made by the secured space intended for the live parts while being installed by the installers and maintenance personnel in accordance to the IEC 60947 edition 5 standard. It covers the power ...
Primary current: 40 A - 800 A
Load voltage: 750 V - 3,000 V
... straightforward maintenance
- Charging contactors: for controlled charging of inter-circuit capacitors
- Line contactors: for connecting main circuits after capacitor
Primary current: 16 A - 63 A
Load voltage: 230, 380, 400, 220 V
... RDCH8 series AC contactor, is mainly applied to circuit of 50Hz or 60Hz, rated operational volteage up to 400V, Rated operational current up to 63A, to control the household appliance and the low induction load, and also can control the ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
Primary current: 250 A
Load voltage: 24, 12 V
... 250A SPST Bi-Stable Remote-Control Battery Isolation Relay is a current isolating electrical switch with mechanical ON-OFF position. This bi-stable relay consumes no power in the ON or OFF states, which makes it well-suited ...
Primary current: 20, 6 A
Load voltage: 195.5 V - 253 V
Primary current: 0 A - 500 A
Load voltage: 0 V - 1,500 V
... The bi-directional DC and AC contactors of the C303 series are designed for operating voltages up to 1,500 volts and can carry currents of up to 500 amps continuously. Magnetic drives with three coil controls make the ...
Schaltbau GmbH
Primary current: 0.15 A - 20 A
Load voltage: 48 V - 600 V
... VAC. It is an effective solution for replacement of electromechanical contactors in commercial and industrial applications that require frequent switching. DRH Series contactors have an innovative design that increases ...
Primary current: 250 A - 5,000 A
... for clamping of product carriers of different thickness without the need to change the setting These contact saddles make contact with product carriers of different thickness (difference 10-15 mm depending on the model) in the same contact without ...
Primary current: 25 A
Load voltage: 220 V
DIGITAL ELECTRIC
Primary current: 25 A
Load voltage: 240 V
DIGITAL ELECTRIC
Primary current: 40 A
Load voltage: 220 V
DIGITAL ELECTRIC
Primary current: 250 A
Load voltage: 1,500 V
... 1500V DC relay features a compact design and high reliability, ensuring the ability to switch power at 1500V. The BSB C8 series 250A DC relay is the ideal choice for 1500V high-voltage energy storage ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 300 A
Load voltage: 1,500 V
... 1500V DC relay features a compact design and high reliability, ensuring the ability to switch power at 1500V. The BSB C8 series 300A DC relay is the ideal choice for 1500V high-voltage energy storage ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 350 A
Load voltage: 1,500 V
... reliable 1500VDC relays ensure the ability to switch power on and off at 1500V. The BSB C8 series 350A DC relays are ideal for 1500V high-voltage energy storage systems, photovoltaic systems, and high- power ...
ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD
Primary current: 20 A
Load voltage: 440 V
... Installation contactors in series HS for installation in distribution boards are extremely quiet and have very low-noise switching processes, are highly versatile thanks to their utilization categories and have a long ...
Doepke Schaltgeräte GmbH
Primary current: 35, 32 A
Load voltage: 230, 400 V
... celduc® relais offers a variety of diagnostic relay solutions. These relays let the user know the status of the load (resistive load), the relay output and the network. Specifications Single phase SSR - Zero cross - diagnostic feature - with output ...
celduc relais
Load voltage: 108 V - 125 V
... Three Pole configurations. Convenient DIRECT-WIRING for Right or Left Hand Power Connections. Rugged Terminals on both sides of the Power Poles for all power connections (NEMA sizes ...
Primary current: 25 A
Load voltage: 600, 220, 380, 415, 440 V
... GSC1-09/3-150/3 Series 3P AC Contactor For remote connection and disconnect circuit, and can be combined with the appropriate thermal overload relay to form an electromagnetic starter, in order to protect the possible overload circuit.(Suitable ...
Tianshui 213 Electrical Apparatus Group CO.,LTD.
... Contactors are electrically remote controlled switches used for switching a power circuit. Those contactors are mainly used for switching electric motors and other resistive, inductive ...
Iskra d.d.
Primary current: 6 A - 800 A
... TemContact 2 is a new range of magnetic contactors and thermal overload relays. Current ratings from 6A to 800A are available in 9 frame sizes and in 3 or 4 pole versions. TemContact 2 has upgraded insulation voltage (from 690V to 1000V ...
Load voltage: 230 V
... is specially-designed for power factor correction capacitor operation the utilization category is AC-6b. The product is pre-charged through resistors that limits the peak current to the contactor when CEM_C special contactors ...
Primary current: 160 A - 350 A
Load voltage: 24 V - 500 V
... Package dimensions [mm] - Volume [cm³] - 8217.715 BF160T4E230 Type of coil: AC/DC coil IEC operating current and power Ie (AC3) 400V [A/Kw]: 230A /110Kw UL/CSA horsepower ratings 480V [HP]: 150 Type of mounting: Screw ...
Primary current: 80, 120 A
Load voltage: 24, 12 V
... and resistant, the D.C. contactors series Tecno are suitable for handling machinery using direct current and for industrial electrical vehicles like lift trucks, cleaning machines, nautical applications, ...
Ravioli spa
Primary current: 20 A - 50 A
Load voltage: 0 V - 3,600 V
... The contactors type HS for both direct (DC) and alternating current (AC) can be used as polarity-independent circuit breakers in electric traction vehicles. They are used primarily as heating contactors, ...
Secheron
Primary current: 1.5 A
Load voltage: 12 V - 32 V
... and contactors at a max. load current of 1.5A. The coil current is reduced to a nominal current of 95% - 5% after a defined time by pulse width modulation. Load current max. 1.5A Load current reduction 95% - 5% Supply voltage ...
... 4pole contactors GH16 series for resistive loads AC‐1 utilization category. ...
GHISALBA
... switch due to the fact that this latter is used to control relatively low power or signals in an electronic environment, while a remote switch is also used to control much higher power levels. ...
Primary current: 40, 63 A
Load voltage: 400, 230 V
... Area of Usage - Small engines - At residential and office, at the power control of the last distribution circuit. - Lighting - Heating, pumps and furnaces - Water heating for home using Impact ...
Federal Elektrik
Primary current: 6 A - 20 A
Load voltage: 380 V
... Coil control voltage:AC12V~440V/50Hz、AC12V~480V/60Hz Electrical Life/AC3:1.2 million times Mechanical life:6 million times Auxiliary contact:Standard 1a(1NO)、Special 1b(1NC) TYPE:S-P06 Rated Power/Current(AC3/3Φ380V):3kW、4HP、6A Rated ...
... been designed by Albright, for use in telecommunication and power distribution applications where the load is infrequently switched. These contactors are primarily for use with Direct Current loads, however ...
ALBRIGHT INTERNATIONAL
Primary current: 900 A
Load voltage: 2,000, 3,600, 1,000 V
... LTX Line contactors are based on the heavy duty and well-known MS technology improved with new advanced high power circuit which permits to achieve the highest performances, robustness and reliability ...
Microelettrica
... Dust-proof cover design ensures higher operation life Applicable scope ‧It is applied electric heater, fan, air conditioning equipment in HVAC facilities, elevators, power systems, food processing machines, lighting, ...
TECO ELECTRIC & MACHINERY Co., Ltd.
... , consult Ross Engineering). Each long life contactor is supplied with 2 form C, SPDT auxiliary contacts rated at 15A, 480V AC. 10A, 125V DC auxiliaries and up to 4 contacts are available. All Ross contactors ...
Ross Engineering
Primary current: 9 A - 630 A
Load voltage: 24 V - 415 V
... Low voltage contactors are produced according to IEC/EN 60947-4-1. They are used remotely to control and protect (in combination with thermal O/L Relays) electrical motors and other electrical Loads such ...
SIGMA ELEKTRIK
Primary current: 4 A
Load voltage: 250 V
... 4A/250V AC Retrofi ttable to the left of all impulse switches S12 and XS12 as well as switching relays and installation contactors R12 and XR12. ½ module = 9mm wide, 55mm deep. ...
... Capacitor Duty Contactors are specially designed for the control of capacitors in PFC panels. ...
Primary current: 32 A
Load voltage: 440 V
... 4-pole plus auxiliary contact, 3 TE, low noise32A (AC1), high Power Ratings, compact sizeClimate resistant, ambient temperatures: -40°C … + 60°CSwitching indicator ...
Primary current: 110, 50 A
Load voltage: 54 V
... Contactor 3 Pole Open 22kW 50A AC3, 54V DC Coil 40V-60V DC Overload = MCOR-3 Pack Size: 12 Specifications • AC3 Current Rating 50.00 • Coil Voltage 54.00 • AC1 Current Rating 110 • Temperature ...
IMO Precision Controls Limited
Primary current: 9 A - 40 A
Load voltage: 690, 600 V
... Front and side-installed auxiliary contacts Coil installed control modules with space saving Reversible coil terminations ( power line or load side) 35mm DIN-Rail installed or panel installed Made by environmental protection material Screw ...
COMESTERO SISTEMI
Primary current: 1,000, 1,250 A
Load voltage: 1.1 kV
... This series vacuum contactor is suitable for power network of AC 50Hz, the main circuit rated voltage 1140V, rated current is 1000A-1250A, for making, breaking, frequently starting and controlling AC motor, and suitable ...
Wenzhou Vacem Technology Co., Ltd
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.