Fully PVDF Pressure Transmitter TPR-21
The enclosure is IP65 protection and the process connection is 1/2" G. The ceramic thick film sensor provides high accuracy of 0.5% FSO in ranges from 0…0.1 Bar up to 0...400 Bar, and 4-20mA output signal 2-wire by DIN connector. It is fully recommended for pressure measurement in very aggressive media or for applications where the sensor fill fluid is not allowed (i.e. Oxygen)
|
|
|
|
|
|
The SPC98 dry and flush mounted ceramic pressure sensor uses an aluminum oxide ceramic sensor as a "dry cell" that is extremely resistant to overload, aggressive mediums, extreme min/max temperature, applications with solid particles and low pressure ranges. These transmitter's are made in either 316 S.S. or Hastelloy C and provide a 4-20mA output signal. The SPC98 is designed to be installed at the bottom of the tank.
FEATURES
*Loop powered, 4-20mA signal output
*Measuring ranges -1 to 580PSI (-1 to 40 bar) gauge /absolute
*Ideal for waste water or other applications with "dirty" medium
*Rugged and compact design- Body entirely 316 S.S. or Hasteloy C
*High accuracy, Excellent repeatability & Temperature compensated
*3A approved
The actual measuring range of the SPC98 sensor is determined by the thickness of the ceramic diaphragm, which if overloaded, stops on the ceramic substrate without sustaining damage. Ceramic cells do not expand and contract nearly as much as metal, ensuring good temperature stability. Common features of the SPC98 are low hysteresis, high repeatability, immunity to the effects of process builds up and outstanding resistance to chemical attack.
|
|
|
|
|
|
New! The Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300
Vaisala introduces a new generation barometric pressure, relative humidity and temperature transmitter series, the Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300. The PTU300 features fully digital measuring electronics for all three parameters, several small RH&T sensor heads for different applications, and calculated humidity variables. The new backlit display shows three-hour graphical trends and up to one year of historical data. The recorded measurement data can be viewed on the display or transferred to a PC. Seven languages options are also available.
The PTU has four different probe options: PTU301 for laboratories, PTU303 for outdoor use, the warmed PTU307 probe for demanding meteorology, and the PTU30T for pressure and temperature measurement only.
The Vaisala BAROCAP® sensor is used for pressure measurement and the Vaisala HUMICAP® sensor measures humidity. Both sensors are known for their high accuracy and long-term stability. The temperature sensor is a platinum RTD sensor.
Applications include environmental monitoring in calibration laboratories, GPS meteorology and weather stations.
|
|
The transducer T7311 is a 3 channel programmable transmitter with an indoor / outdoor temperature, hunidity and barometric pressure probe.
Temperature probes and transducers for Pt1000/3850ppm sensor with two-wire connection and RS232 interface are built in a durable watertight case. Output temperature range is user adjustable. Degrees Celsius and Fahrenheit are user selectable. Large dual line LCD is an advantage. Display is possible to switch off. Computerized design ensures maximum long term stability and fail indication.
|
|
E2405 series differential pressure transmitters are intended for measurement of low absolute, differential or gauge pressure of air or non-corrosive gases. The main application area is the building automation, eg filter control.
- Low absolute, gauge or differential pressure measurement in HVAC applications
- Analog output 4-20 or 0-10 V
- Output scale from 50 Pa to 100 kPa (0,5 mbar to 1 bar)
- RS485 Modbus RTU interface option for direct Fieldbus networking
|
|
DPT – Differential Pressure Transmitter for low pressures
The DPT differential pressure transmitter is used for detecting over- and under-pressure and differential pressure. The DPT is suitable for air and non-aggressive gases. Typical applications are monitoring and control of ventilation and air-conditioning, fans and filters.
|
|
|
The Series 251 wet/wet differential pressure transmitter utilizes a double diaphragm sensor technology that outperforms standard double sensor products in accuracy, reliability and static operating pressure. This differential pressure sensing technology offers 0.25% accuracy with static operating pressures up to 1000 PSI. The Series 251 features 316 stainless steel construction designed to meet NEMA 4X (IP 65) standards. The transmitter also offers exceptional field flexibi ity with a 5:1 turn down and comes standard with a certificate of calibration.
|
|
|
The Series 211 Differential Pressure Transmitter can accurately measure positive, negative, or differential pressure and send the corresponding 4-20 mA output signal. The Series 211 Differential Pressure Transmitter is not position sensitive and can be mounted in any orientation without compromising accuracy. It also features a power LED, so you always know when the transmitter is operating. The compact, lightweight design makes installation simple and easy.
|
|
SPD 92 Differential Pressure Trasmitter
The SPD92 Sitron's Differential Pressure Transmitter is the ideal solution for level application with differential pressure in liquids and gases (air).
Small and compact, the SPD92 is offered in a 316SS body with a 4-20mA or 0-10V output and several types of process connections.
Pressure Ranges: 0.2 to 300 PSI
|
|
With the VEGADIF an effective system for the measurement of differential pressure, level and flow is available.
The instruments are suitable for differential pressure as well as positive and negative gauge pressure.
VEGADIF is the ideal solution for all types of applications in many industries:
- in process control industries
- in chemical industries
- in pollution control.
The measured products can be gaseous, steamy, liquid or even highly viscous.
Product and process wetted materials and construction types ensure reliable use even in aggressive or abrasive products as well as in applications with high hygienic requirements e.g. in the food processing and pharmaceutical industries.
User features
- Spans from 1 mbar to 40 bar
- Nominal pressure up to 420 bar
- Accuracy better than 0,1 %
- Longterm stability better than 0,1 %/12 months
- highly overload resistance silicium sensors
- Continuous self-monitoring
- Quick set-up and easy operation
- Unpressurized adjustment (dry adjustment)
|
|
|
|
|
|
Differential pressure transmitter with metal measuring diaphragm
Application area
The differential pressure transmitter VEGADIF 65 is used for various applications such as flow measurements in gases, vapours and liquids in conjunction with effective pressure transmitters. Also level measurements of liquids in pressurized vessels as well as pressure monitorings on filters and pumps are typical applications.
Advantages
Very good reproducibility and long-term stability
Deviation < 0.075 %
Comprehensive isolating diaphragm program
High resistance diaphragm materials
Product temperature up to 400 °C
Function
The separating diaphragms of the sensor are deflected by the existing pressures. The filling oil transmits the pressure to a semiconductor measuring bridge, the differential pressure dependent output signal of which is measured and further processed. The advantages of this sensor are the high system pressure up to 420 bar, the excellent longterm stability and the very high, unilateral overload resistance.
|
|
|
|
|
|
P 26
Intelligent differential pressure transducer
with scalable measurement range.
Sensitive measurement technology in innovative housing
Demands for increased quality in nearly every area of industry have subjected pressure gauges to sophisticated demands as well. These include clean room monitoring and the ability to monitor sterile environments in the packaging machines used in products for such industries as foods and pharmaceuticals. The new P 26 differential pressure transducer from halstrup-walcher has been specially designed to meet these demands.
The P 26 is a differential pressure transducer that meets these particularly sophisticated demands. Measurement ranges between 100 Pa and 100 kPa are freely scalable from 10 to 100%, and provide the option of switching to other units of measurement like mmH2O, mmHg, etc. Cyclical self-calibration of the zero point ensures a high level of measurement stability. Two cutoff points are available that can be set freely along the entire measurement range; these allow the user to connect visual or audible alarms that would be triggered any time values fall above or below limits. All measurement values can be clearly read on an optional graphic LCD. The instrument can, if necessary, communicate with a master control unit via an RS 232 interface and can be mounted either on a wall or on top-hat rails.
A hand-held unit can be used as a configurator for the one-time calibration when using more than one of the affordable P 26 pressure transducer without a display.
|
|
The differential pressure transmitter portfolio from ABB offers a broad variety of communication possibilities. Another highlight of our sensors is the measurement accuracy up to 0,04%.
From the simplest concept to the smartest measurement solution, 364 is evolving the pressure transmitter concept by simplification and common sense design. 364 represents the best solution for hazardous areas and high demanding flow, level and pressure applications.
Simplicity and compactness are the key to the new ABB platform for pressure measurements.
- Long term stability of 0,15% for 10 years
- The solution for multiple installation in reduced spaces
- All stainless steel construction with smart drain/vent solution
- Boltless and gasket-free one piece body design
- On board LCD display with intuitive menu navigation
- Bi-directional flow and totalization capability
|
|
Differential pressure transmitter type FDA602D
This measures the differential pressure in liquid and gaseous
media indirectly using two absolute pressure sensors.
This makes it less expensive but more robust with respect to
asymmetrical overload.
The differential pressure range should be at least 5% of the
standard pressure range.
Each side of the sensor incorporates two pressure
connections. The transmitters can thus be used easily and
conveniently in pressure pipes.
It incorporates a high-speed, high-precision microprocessor.
All reproducible errors affecting the pressure sensors, i.e.
involving non-linearity and temperature dependency, can be
completely eliminated by means of mathematical error
compensation.
|
|
Differential Pressure Unit
With more than one million BARTON DPU-based instruments in service around the world today, Cameron's Measurement Systems division is a premier supplier of reliable and accurate chart recorders, indicators, switches and pneumatic controllers. Originally developed in the early 1920s, our differential pressure technology features a welded bellows assembly that increases accuracy while dramatically reducing the effects of wear. To facilitate quick and easy repairs all DPU based instruments are supported with pre-calibrated exchange or repaired sub-module bellows assemblies.
|
|
|
|
|
|
Honeywell offers a full line of pressure transmitters for a wide variety of industrial applications.
ST 3000 Series 100 - Absolute
Honeywell ST3000 Series 100 absolute pressure transmitters are used in applications in which high accuracy in the vacuum range of pressure is needed to include low-pressure measurement in vacuum distillation columns, where energy savings are directly proportional to the vacuum in the column.
ST 3000 Series 100 - DP
Honeywell’s ST 3000 S100 differential pressure transmitter can be used with any primary flow element to provide proven, repeatable flow measurement, from furnace combustion airflow rate to hydrostatic tank gauging.
ST 3000 Series 900 DP
Honeywell's ST 3000 Series 900 Differential Pressure Transmitters bring proven smart technology to a pressure measurement applications, from furnace combustion airflow rate to hydrostatic tank gauging. It can be used with any primary flow element to provide proven, repeatable flow measurement.
ST 3000 Series 900 Gauge
Honeywell's ST 3000 Series 900 gauge pressure transmitter applications include high-pressure measurement in boilers, fuel feeds and high-pressure reaction vessels in the petrochemical and hydrocarbon recovery industries or in any location where accuracy and reliability are crucial to safe, economical operation.
|
|
Since 1948, when Foxboro invented the first d/p cell transmitter, our differential pressure transducers and transmitters have been the industry standard.
Today our IDP series intelligent two-wire transmitters are still leading the industry with a complete offering of measurement ranges, static pressure ratings, materials, analog and digital communications and premium performance.
Our traditional and low-profile structures offer superior performance and long-term stability from microprocessor-based technology.
Features:
- Application versatility
- Rugged dependability
- Superior performance
- Choice of electronic modules
- LCD indicator / pushbutton configurator
|
|
The differential pressure transmitters of the Type 694 series incorporate a proved ceramic fulcrum lever technology. They deliver calibrated, temperature-compensated sensor signals, available as standard voltage or current outputs.
They are ideal for registering low air flow in air conditioning systems and for the measurement of fine pressures in environmental, laboratory and clean-room applications (air and non-corrosive gases).
|
|
The pressure transmitter of product range type 663 have calibrated and temperature compensated sensor signals which are available as voltage output.
The amplified linear voltage output signal, can be connected directly into an electronic control system.
The transmitter can be mounted directly due a pcb board or with a 2.5 mm plug connection.
|
|
Our new two-wire, loop-powered transmitter offers users more flexibility. Because there is no need to bring external power to the unit, installation time and cost are reduced.
Offered on:
>> Differential pressure (with indicator option)
>> Flow (with indicator option)
A 4-20 mA (two wire) output is available for loop-powered installations, which offers the user the most savings in installation. A 0-5 VDC (three or four wire) output also is available as standard. The input voltage is 9-35 VDC.
The transmitters are built on the same pressure body as our high line pressure (to 5,000 psi) gauges and switches. Select from many different pressure ranges (0-5" H2O to 0-1000 psid) and flow ranges (0-1 GPM to 0-10 GPM).
Built for difficult industrial applications, a weatherproof enclosure protects the electronics with Class 1, Div. 1&2, Nema 4X and IP65 ratings. A 7/8" (22 mm) knockout is standard for 1/2" conduit connections.
|
|
Description & Features:
• Designed to measure the wet to wet differential pressures of liquids and gases
• Compact, efficient design available in Low or High psi ranges that facilitates installation in tight spaces
• Low Range housing is constructed of stainless steel and aluminum
• High Range housing is made from a 316-grade stainless steel ideally suited for an industrial environment
• Fast response sensor and signal conditioned electronic circuitry provide quick and accurate readings
• Unique isolation system responds to pressure changes approximately 20 times faster than conventional transmitters with ranges below 100 psi (Low Range Model)
• CE approval is standard on all models
• NEMA 4 approval is standard on the Low Range model
• 1 year warranty
Applications:
• To measure drops across filters
• Pumps and compressors, flow measurements of gases and liquids, liquid level measurement of pressurized vessels
|
|
|
|
|
|
Smart differential pressure transmmitters model APR-2000 ALW with Hart protocol/Profibus PA.
Smart differential pressure transmitters model APR-2000ALW are applicable to the measurement of differential pressure transmitters of gases, vapours and liquids. The active sensing element is a piezoresistant silicon sensor.
Smart differential pressure transmmitters model APR-2200ALW with Hart protocol/Profibus PA.
Model APR-2200ALW differential pressure transmitter with two diaphragm seals is applicable to the measurement of pressure difference of: gases, vapours and liquids. Typical applications for this transmitters are: Level in closed tanks, density and the measurement of a filter loss.
Smart differential pressure transmitter for low range APR-2000GALW with Hart protocol/Profibus PA is applicable to gases, to the measurment of their pressure , underpressure and differential pressure. Measuring range: min. 0...0,2 mbar; max. 0... 200 mbar
All above-mentioned transmitter can be programmed through:
- hand-held Hart communicator model KAP-03(Aplisens) or other
- PC with software Raport-01 or other
- local adjustment which allows setting of the following parameters:/ measuring range adjusted without pressure source, measuring range adjusted with pressure source, zeroing, measuring units, damping, type of characteristic, starting point of sqrt characteristic, display setting, factory setting.
|
|
Yokogawa has more than 45 years' experience in the development, design, and manufacture of pressure sensors and pressure transmitters. The DPharp series of digital pressure transmitters use a differential pressure high accuracy resonance (DPharp) sensor that represents one of the most revolutionary advances in transmitter technology.
EJX Series
The new DPharp EJX transmitters are the latest addition to the DPharp family's EJA series. DPharp EJX transmitters employ a next-generation multi-sensing technology that provides virtually the highest level of performance and precision in the market.
EJA Series
The DPharp EJA series of intelligent differential pressure and pressure transmitters features high performance, durability, and reliability. The pressure detector, the core of the transmitter, uses a silicon resonant sensor that has proven to be highly reliable in the field and offers a complete product lineup.
|
|
|
Analog and digital indicating units and transmitters for liquid level, differential pressure and flow measurement. Media 6 allows for connection of the dp-cell to your PC in the logistics center.
|
|
Sensor for differential pressure and volume flow, explosion proof
Electrical, explosion proof differential sensors series ExCos-P and RedCos-P, in acc. with ATEX 94/9/EC for use in hazardous areas zone 1, 2, 21 and 22 (in acc. to sensor type), for all kind of gas, mixtures, vapours and dust. 24 VAC/DC supply, Measuring range /- 100 Pa, /- 250 Pa, /- 600 Pa, /- 1250 Pa, /- 2500 Pa, /- 5000 Pa, /- 7500 Pa. Working range adjustable, output 0...10 VDC and 4...20 mA, actual value indication, aluminium housing IP 66, integral Ex-e terminal box. Series ExCos-P for use in Zone 1, 2, 21, 22. Series RedCos-P for use in zone 2, 22.
The module is for installation inside the hazardous area, an interface in the safe area is not required, installation of intrinsic safe circuit is not required. This saves cost, space and guarantees safety.
|
|
|
|
|
|
Transducer and switching modules for temperature, humidity and pressure, explosion proof
Electrical, explosion proof trandsucer, series ExCos-A, RedCos-A, ExCos-D, RedCos-D and EXL-IMU-1 as well as switching modules series EXL-IRU-1, to connect modulating or binary temperature, humidity and pressure sensors, in acc. with ATEX 94/9/EC for use in hazardous areas zone 1, 2, 21 and 22 (in acc. to sensor type), for all kind of gas, mixtures, vapours and dust. 24 VAC/DC supply, adjustable on site, integral display for programming and for actual value indication.
Series ExCos-A for modulating, analogue sensors (type ExSens) and ExCos-D for modulating, digital sensors (type ExPro), for use in hazardous areas zone 1, 2, 21 and 22. Series RedCos-A modulating, analogue sensors (type ExSens) and RedCos-D for modulating, digital sensors (type ExPro), for use in hazardous areas zone 2 and 22.
Series EXL-IMU-1 for modulating, analogue sensors (type ExSens) for use of sensors in zone 1, 2, 21 and 22. The module must be installed in the safe are and is prepared for DIN rail mounting.
Series EXL-IRU-1 for binary, analogue sensors (type ExSens) for use of sensors in zone 1, 2, 21 and 22. The module must be installed in the safe are and is prepared for DIN rail mounting.
|
|
PTX 600 Series Precision pressure transmitters
For critical applications in industrial and research environments the PTX 600 series of two wire, 4-20mA output pressure transmitters improves upon the performance of previous models by offering new levels of stability, versatility and measurement accuracy from a standard production device.
Druck's well proven silicon technology has been developed to provide a miniature micro-machined diaphragm which is electrostatically bonded to a glass substrate and stitch bonded within a glass to metal seal assembly to provide exceptional thermal and stress isolation.
Features & Benefits:
Ranges from 1.5 psi to 10,000 psig or psia
Output 2-wire, 4-20mA
Accuracy ±0.08% FS BSL
Stability 0.1% FS per year
TEB ±1%FS from -5° to 176°F
400% FS Overpressure
NACE compatible Hastelloy and 316L SS wetted parts
UL/CSA/FM/CENELEC IS Class I, Div 1, CE Marked
|
|
ATEK MELT PRESSURE TRANSMITTERS provide accurate and repeatable measurements, are designed for high temperatures in applications such as plastics extrusions, oil services, food and medical, injection, blow molding, and resin production
- Good Stability and Anti-Jamming capatibility
- Economical Price
- Zero and Span Adjustable
- Various Amplified Signals Optional
4 - 20 mA , 0 - 10V or 3.33mV/V
- Flexible Capillary Isolation Configuration
- Internal 80% Shunt Calibration
|
|
Ashcroft® low differential pressure transmitters provide unmatched, full-scale terminal point accuracy, including non-linearity, hysteresis and non-repeatability.
Types include:
*Ashcroft® Xldp - Durable, flameproof NEMA 2 stainless steel construction
*Ashcroft® IXLdp - Industrial NEMA 4X metal construction, FM approved for hazardous locations
*Ashcroft® RXLdp – Reduced size mounts inside a standard 3 1/2 " electrical box
*Ashcroft® DXLdp - DIN rail mount reduces footprint area 4:1…SpoolCal[TM] feature allows on-line verification and calibration
[Ashcroft DXLdp shown]
|
|
|
|