- Detection - Measurement >
- Electrical Measurements >
- Voltage detector
Voltage detectors
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
• Phase identification at all voltage levels in real time • GPS connection and GPS cache (1 h buffer) • Measurement on LV, HV, and capacitive test points • Easy to operate via touch display ...
MEGGER
Detects the presence of a.c. voltage at: • Socket outlets • Fuses • Switches • Wires and cables • Circuit breakers • Luminares Check for the presence of a.c. voltage, signalled by a bright ...
MEGGER
... functioning of two-pole voltage detectors. The device safely generates a range of voltages from 50 to 690 V in five steps. At switch on, the unit initially generates 690 V then, after ...
MEGGER
Pen phase detector with integrated torch Pen phase detector HT20 allows very quickly checking for the presence of AC voltage on any kind of electric installation with and without direct ...
HT
... The KD1E is a neon HV potential indicator suitable for use on earthed neutral systems up to 11kV. A highly robust, portable AC/DC voltage indicator, this potential indicator provides a means of confirming ...
Seaward
... The KD1E/19 is a neon HV potential indicator suitable for use on earthed neutral systems up to 19kV. A highly robust, portable AC/DC voltage indicator, this potential indicator provides a means of confirming ...
Seaward
... The KD1E/22 is a neon HV potential indicator suitable for use on earthed neutral systems up to 22kV. A highly robust, portable AC/DC voltage indicator, this potential indicator provides a means of confirming ...
Seaward
The capacitive measuring method enables a non-contact voltage measurement that can be carried out quickly and easily. The LED glow lamp starts pulsating as soon as the measuring tip detects a voltage ...
... Non-Contact AC Voltage Detector designed for indoor use. It has a sensitivity range of 120 to 240VAC, detection distance of <5mm, and overvoltage of 600V. This detector carries a safety ...
AEMC Instruments
... Incorporated high voltage power supply, input voltage 24V DC No high voltage cables needed wo-colour status LED: - Green LED: signals operation OK - Red LED: An intermittent LED signals ...
... CM5 high voltage generator and is communicated with an output signal and the flashing of the red LED. - Detection of perforations over a large area - Detection of very small perforations possible Housing - ABS/PTFE Cable ...
... obtained. Refer to the table below: - Convenient high-voltage indicator in pen size - There is no need to make contact with the device being controlled - The tip of the TensION illuminates when a voltage ...
Low Voltage detector and voltage multitester DETEX. LCD screen. Application: Check the presence of voltage. Voltage measurement: up to ...
CATU
Application: Check the presence of voltage. Checks voltage levels from 12 to 900 V AC, 1 000 V DC. (According to models) Sound and light continuity for a non-live circuit. (threshold of 200 ...
CATU
Low Voltage detector DETEX Application: Check the presence of voltage. Checks voltage levels from 12 to 900 V AC, 12 to 1 000 V DC. (According to models) ...
CATU
... from Hioki is a twin light audible voltage detector. The device has top primary supply level safety class rating for voltage detectors. Its CAT IV 600V design matches ...
HIOKI E.E. CORPORATION
Features: Non-contact detection of AC Voltage from 100 to 1000VAC For use on 50/60Hz circuits Rugged double-molded housing Green LED indicator lights up when powered on and ready to use Flashing Red LED indicator light ...
Extech
HVD high voltage indicator is adapted for indoor electrical panel, used in MV / HV switchgear. It is connected via internal wiring to capacitive sensors inside the switchgear. Rated voltage ...
... width detection of 10 ns 32 inputs on BNC connectors (TTL, 50 Ω) Single high-power high-voltage supply output (+2000 V @ 1 mA) Single high-power low-voltage supply output (+5 V @ 1.5 A) 10/100T Ethernet ...
CAEN Spa
... output (HDMI) to externally monitor the state-of-health of the device Single high-power high-voltage supply output (+2000 V @ 500 μA) Two high-power low-voltage outputs (+5V / +12V @ 1 A) 1 GbE and ...
CAEN Spa
... automatically downloaded onto a USB flash drive. The UDCM also features a programmable negative High Voltage (HV) power supply providing detector bias voltage from 0 to -1 kV. The ...
CAEN Spa
MV Voltage detector 1 - 69 kV Standards IEC 61243-1 VOLTAGE DETECTORS CAPACITIVE TYPE TO BE USED FOR VOLTAGES EXCEEDING 1 kV A.C. ...
PENTA
... equipment. Technical specifications Electric field detector : Detector operating range: 2 kV to 400 kVReference detection distance: ≈ 2 metres from a conductor located at a height of 1.5m at a voltage ...
PENTA
50 -765 kV voltage detector Standards IEC 61243-1 (2009) VOLTAGE DETECTORS CAPACITIVE TYPE TO BE USED FOR VOLTAGES EXCEEDING 1 kV A.C. CE: Compliance ...
PENTA
MS104K-S portable diffusion gas detector is a compact, ultra-low power consumption, mobile rapid detection of gas concentration detector, that can detect 1 to 4 gases at the same time, with a large capacity ...
Beijing Zetron Technology Co., Ltd
PTM600-S can simultaneously detect toxic and combustible gases, suitable for the dangerous or hazardous space, such as tunnels, culverts, storage rooms and other restricted spaces where the air can not be circulated. The system could ...
Beijing Zetron Technology Co., Ltd
MS104K portable 4-in-1 gas detector MS104K diffusion type toxic and harmful gas tester is a mobile rapid detection of the gas concentration of composite gas detector, up to 1 ~ 4 kinds of gas detection ...
Beijing Zetron Technology Co., Ltd
... productivity. Features of UT262E Non-Contact Phase Detector Certificates: CE, UKCA ● Phase-detection ● Phase missing detection ● Phase sequence detection ● Non-contact detection ● Three-phase AC voltage: ...
... traps, dehumidifiers, flow meters and other units for drying and filtering, and then enters the intelligent PID organic gas detector, with advanced spectroscopy technology, the concentration of VOCs in the gas is measured. ...
... as μmol/m/s (micromoles of photons per meters squared per second). The low output Voltage of the sensor can easily be converted to a 4-20mA current or higher Voltage using the MS-4.20mA converter. ...
... range from 90 to 1000V • indicates live conductors • continuity buzzer • optic signalization of voltage presence by flashing LED (quite cycle) • voltage range: 90 ~ 1000VAC • frequency: 50/60Hz • ...
The TECPEL HVP-275 is a high voltage proximity detector.It has eight voltage detection settings from 240Vac to 275kVac. The HVP-275 consists of an internal pickup sensor plate, a sensitivity ...
Voltage Sensor KEW 8309 Floating voltage can be measured *Floating voltage: phase to phase voltage not grounded Max. input voltage |AC 600Vrms(sin), ...
... One-key call for help/telephone function to ensure communication in emergencies - Real-time wireless communication with gas detectors, alarms are immediately known - Heart rate detection, abnormal heart rate will be ...
The TQC Low Voltage Pinhole detector enables the user to inspect various coatings on conductive substrates for small defects such as holidays and pinholes using the ‘wet sponge technique’. The grounding ...
... resulting current); Communication failure between group equipment; Neutral angle (resulting current); Low voltage alarm of ultra capacitors; Loss detector, among others.
The TS200 medium voltage detector is a product designed to detect events that occur in medium voltage electrical networks, up to 34.5 kV. It is a system that monitors the distribution ...
... TS200 low voltage detector is a product designed to detect the absence/presence of voltage in electrical networks up to 380v phase to phase. It uses a system to read the voltage ...
Detector fitted with a notched insulating end-piece for attaching to an insulating rod. Unipolar electronic detector for checking the absence or presence of the high-voltage. Device ...
DIGITAL PHASE DETECTOR PD3259 Digital Phase Rotation Meter with Three-Phase Voltage Measurement Functionality Overview Hioki’s non-contact voltage detection and measurement technology ...
VOLTAGE DETECTOR 3481 Non-Metallic Contact Voltage Detector with LED Light Overview Hioki leads the industry in non-metallic contact test and measurement technology ...
TSV100 is an AC voltage detector with galvanic isolation and IP30 protection. TSV100 is an AC voltage detector with optoisolated open collector output. It detects voltage ...
Your suggestions for improvement:
A voltage detector tests the presence or absence of voltage in an electrical line. Both pen and portable multimeter-type models exist.
ApplicationsThese devices are used by electricians to verify that there is no voltage in the circuit on which they must work.
TechnologiesSuch testers can detect very small voltages. They have a cord long enough to reach a ground point, while the other contact is usually found at the end of the device. Results are displayed on an LCD screen, indicated by LEDs or an audio signal. Many also indicate resistance, rotating field and phase. The tester is checked both before and after each use by touching the two contacts together.
The screwdriver tester with a neon bulb in its handle does not protect the user against short-circuits and is prohibited in professional settings. Electronic non-contact testers are replacing these devices for simple, low-voltage testing. Digital multimeters are subject to calibration errors and are sensitive to nearby inductive fields, making them unreliable for test work.
Choice will depend on the voltage range, display type and additional features.
- Safety for electrical work
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining