- Detection - Measurement >
- Electrical Measurements >
- Voltage current transducer
Voltage current transducers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 5 A - 40 A
... unstable loads, etc.). Description: - AC Current Transducer to DC current (4..20 mA - loop-powered) Input: - 8 selectable scales via DIP-SWITCH ...
Primary current: 5 A - 40 A
... ease of use, and compact dimensions, the T201DC fits every kind of current measurement to 40 Adc. Description: - DC Current Transducer to DC current ...
Primary current: 0 A - 100 A
... passive, contact-less loop-powered direct current transducer. The T201DC100 has functions and looks very similar to a standard current transformer, but it has stress features of measuring ...
Primary current: 500 A
... Measure range about 3*ipn •Working voltage(supply voltage of the sensor): DC ±12V~ ±15V •Output: ±4V •Linearity: class 1 (±1%) •Accuracy: class1 (±1%) •Square perforation 10*20mm, ...
Primary current: 1,000 A
... SCK4 Series open-loop hall effect current sensor, galvanic isolation between primary and secondary circuit provides accurate electronic measurement of DC, AC or pulsed currents. Characteristics •Open-loop ...
Primary current: 1,500 A
... SCK4 Series open-loop hall effect current sensor, galvanic isolation between primary and secondary circuit provides accurate electronic measurement of DC, AC or pulsed currents. Characteristics •Open-loop ...
Primary current: 5, 1 A
Programmable transducer 8 Module Just one meter for single-phase and 3-phase connections Wholly field programmable Direct three-phase voltage input up to 500V andthrough V.T. 100 and 115V Current ...
... Accuracy PCB Mount Current Transducer 0-10V) adopts a special isolation module to convert the measured AC voltage into an AC current ...
Primary current: 0 A - 5 A
... parameters; Power supply: AC/DC 85~265V; Accuracy: 0.5 class; Response time: less than 320mS: Maximum display: 9999, variable ratio: 1-9999; Power consumption: ≤3.5VA; Distinguishability: voltage: ...
SHENZHEN SENSOR ELECTRONIC TECHNOLOGY Co., LTD.
Primary current: 0 A - 1,000 A
This device is an AC high current electrical isolation transducer, Its input and output are not common grounded. The input signal is AC current, and ...
SHENZHEN SENSOR ELECTRONIC TECHNOLOGY Co., LTD.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining