Hoffer Flow Controls

Turbine flow-meter for liquids
35 - 650 gpm, -40 450 °F, max. 6 000 psig | HO-STAR-105F Hoffer Flow Controls

TURBINE FLOWMETERS FOR LIQUID SERVICE
Product Bulletin HO-STAR-105F:

Linearity: ±1.0% of reading or better.
Repeatability: ±0.1% of reading or better.
Temperature Range: -20°F to +450°F (Standard).
Signal Output: 10 MVRMS or greater into a
10K ohm load at minimum flow rate.
Materials of Construction:
Type 316/316L dual rated Stainless
Steel (with exceptions noted below).
Rotor: 17.4 PH Stainless Steel.
Bearings:
Hard Carbon Composite (Standard).