-
{{>productsMenu}}
- Catalogs
-
{{>projectsMenu}}
-
{{>trendsMenu}}
- E-MAGAZINE
- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Ultrasonic flow meter
Ultrasonic flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Process pressure: 0 Pa - 1,586,000 Pa
Process temperature: 0 °C - 50 °C
In-Line Ultrasonic Flow Meter • Economical Ultrasonic Flow Meter for Water Service • DN 32 to 200 (2 to 8") Flanges • Battery Powered • ...
OMEGA


ultrasonic flow meterSITRANS F US SONO 3300 , SITRANS FUS060
Process pressure: 0 bar - 40 bar
Process temperature: -40 °C - 160 °C
Volumetric flow rate: 10 m³/h - 2,200 m³/h
The SITRANS F US SONO3300/SITRANS FUS060 flowmeter consists of a SITRANS F US SONO 3300 sensor and a SITRANS FUS060 transmitter. The sensor is available in carbon steel and is fitted with integrated transducers. It also ...
Siemens Process Instrumentation

Process temperature: 40 °C - 230 °C
Precision: 1 %
Repeatibility: 0.25 %
SITRANS FS290 is a portable ultrasonic flowmeter system for monitoring volumetric flow in pipes. It contains the SITRANS FST090 battery-operated transmitter and SITRANS FSS220 clamp-on ...
Siemens Process Instrumentation

Process pressure: 0 bar - 40 bar
Process temperature: -20 °C - 85 °C
Volumetric flow rate: 28 m³/h - 4,200 m³/h
The SITRANS F US SONO 3100/SITRANS FUS060 flowmeter consists of a SITRANS F US SONO 3100 sensor with O-ring or flange transducers depending on the application. The SITRANS FUS060 transmitter is engineered for high performance ...
Siemens Process Instrumentation

Process pressure: 0 Pa - 20,000 Pa
Process temperature: -20 °C - 50 °C
Volumetric flow rate: 0 m³/h - 4 m³/h
Residential Ultrasonic Gas Meter USM-G2.5 USM Series Ultrasonic Gas Flow Meter is a type of electronic meter that adopts TOF (Time ...
Cubic Sensor and Instrument Co.,Ltd

Process pressure: 0 Pa - 20,000 Pa
Process temperature: -20 °C - 50 °C
Volumetric flow rate: 0 m³/h - 6 m³/h
Residential Ultrasonic Gas Meter USM-G4 USM Series Ultrasonic Gas Flow Meter is a type of electronic meter that adopts TOF (Time ...
Cubic Sensor and Instrument Co.,Ltd

Process pressure: 0 Pa - 30,000 Pa
Process temperature: -20 °C - 50 °C
Volumetric flow rate: 0.1 m³/h - 25 m³/h
Commercial Ultrasonic Gas Meter USM-G6/G16 USM Series Ultrasonic Gas Flow Meter is a type of electronic meter that adopts TOF (Time ...
Cubic Sensor and Instrument Co.,Ltd

Process pressure: 200 psi
Process temperature: 20 °F - 120 °F
Volumetric flow rate: 2 m³/h - 3,398 m³/h
... models. Available for measuring air flow in SCFM or m3/hr on 1/2" thru 8" Schedule 40 Iron Pipe, 25mm thru 101mm Aluminum Pipe and for Copper Pipe up to 4". Advantages Provides wireless monitoring of EXAIR flowmeters ...

Process pressure: 0 psi - 200 psi
Process temperature: 20 °F - 120 °F
Volumetric flow rate: 2 m³/h - 3,398 m³/h
... most models. Available for measuring air flow in SCFM or m3/hr on 1/2" thru 8" Schedule 40 Iron Pipe, 25mm thru 101mm Aluminum Pipe and for Copper Pipe up to 4". Provides wireless monitoring of EXAIR flowmeters ...

Process pressure: 50, 100, 4,000 psi
Process temperature: -50 °C - 100 °C
Precision: 0.1 %
... of changing flow dynamics such as blockages upstream of the meter, abnormal flow profiles and liquid hydrocarbons. MeterLink™ Software displays a wealth of predictive diagnostics generated ...

Volumetric flow rate: 50 l/min - 200 l/min
The SU type ultrasonic flow rate sensor with robot inline design are used to monitor volumetric flow rates, temperature of the medium and offers suitability in water, oil and glycol ...

Process pressure: 0 bar - 100 bar
Process temperature: 0 °C - 60 °C
Volumetric flow rate: 0 l/min - 1.5 l/min
Liquid Independent Measurement of Low Volume Flow Rates ES-FLOW™ are Volumetric Liquid Flow Meters for very low flow ranges. The instruments operate ...

Process pressure: 11 bar
Process temperature: 0 °C - 80 °C
Precision: 1.5, 3 %
Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic ...
Endress+Hauser AG

Process pressure: 16 bar
Process temperature: 80 °C
Volumetric flow rate: 0 l/min - 240 l/min
The Flow detector for performing and non-performing fluids, solid plan without touching parts, maximum course temperature and pressure of 80 °C and 10 bar respectively, maximum chemical confrontation attributable to seal-free ...
SICK

Process pressure: 0 bar - 16 bar
Process temperature: 0 °C - 143 °C
Volumetric flow rate: 0 l/min - 250 l/min
... flexible flow measurement The non-contact DOSIC® flowmeter detects the flow volume of conductive and non-conductive liquids based on ultrasonic technology. With its ...
SICK

... the contact-free and accurate measurement of flow velocity and flow direction inside tunnels or exhaust ventilation ducts. Ultrasonic technology provides the cross-sectional mean average ...
SICK

Process temperature: 0 °C - 50 °C
... chain Ultrasonic Flow Converters are coupled with Series SX3 series sensors with the intention of using the transfer-time calculating technique. Two ultrasonic detectors are installed ...
DWYER

Process pressure: 3 bar - 16 bar
Process temperature: -10 °C - 45 °C
Volumetric flow rate: 0 l/h - 50 l/h
The flow meter DulcoFlow® reliably measures pulsating flows in the range above 0.03 ml/stroke based on the ultrasound measuring principle. The flow meter ...

Process pressure: 6 bar - 100 bar
Process temperature: -200 °C - 250 °C
Ultrasonic flowmeter for liquid process applications • Accurate 3-path meter: large dynamic range, maintenance-free, no pressure loss • Cryogenic (-200°C/-328°F) and HT (+250°C/+482°F) ...
KROHNE Messtechnik

Process temperature: 180 °C
Ultrasonic flowmeter for district heating applications • 3-path meter for thermal energy measurement and heated water • CT: OIML R75, MID MI-004 (Class 1, 2, 3) • Flange: DN25…2000 ...
KROHNE Messtechnik

Process temperature: -40 °C - 120 °C
Ultrasonic clamp-on flowmeter for temporary flow measurement of liquids • Portable, battery-powered meter, for on-site verification of process flows ...
KROHNE Messtechnik

Process pressure: 0 bar - 0.69 bar
Process temperature: -20 °C - 60 °C
Repeatibility: 0.5 %
The area-velocity flow measurement method is the most common method of all flow measurements. The Greyline Area-Velocity Flow Meter uses a submerged ultrasonic ...
Pulsar Measurement

Process pressure: 0 psi - 10 psi
Process temperature: -23 °C - 60 °C
Volumetric flow rate: 0 m³/s - 0 m³/s
... DFM 6.1 is designed to measure flow from outside a pipe for "difficult liquids" that would damage regular flow meters - wastewater, slurries, sludge, chemicals, viscous liquids, and abrasives. ...
Pulsar Measurement

Process temperature: -20 °C - 50 °C
Flow Monitor is a dedicated wall-mounted device that is for use with Pulsar’s FlowPulse flow sensor, in fixed or permanent installations. The Flow Monitor ...
Pulsar Measurement

Process pressure: 0 bar - 16 bar
Process temperature: 5 °C - 90 °C
Volumetric flow rate: 0.1 l/min - 200 l/min
... (nominal flow rate 3.5 m3/h namely 58 l/min) - model QN 6.0 DN25: 1 to 200 l/min (nominal flow rate 6.0 m3/h namely 100 l/min) Ultrasonic flowmeter using transit ...

Measure flow rate accurately At the core of all PULSE ultrasonic chemical injection metering valves (CIMVs) is a nonintrusive, line-of-sight ultrasonic flowmeter that ...
CAMERON

Process temperature: -40 °F - 350 °F
DXN Portable Hybrid Ultrasonic Flow Meters The Dynasonics DXN meter is a powerful tool for troubleshooting flow issues, whether you want to quickly ...
Badger Meter

Process temperature: -30 °C - 70 °C
Cost-efficient alternative to conventional EMFs/mag meters. For continuous flow measurement in slight to heavily polluted media in full pipes
NIVUS GmbH

Process temperature: -30 °C - 70 °C
... General Description The OCM F flow metering system utilises a fully bidirectional ultrasonic velocity sensor. The intelligent Doppler sensor detects and directly evaluates the flow ...
NIVUS GmbH

Process temperature: -40 °C - 85 °C
Self-sufficient measurement station with integrated data transmission via GPRS. For discontinuous flow measurement in slight to heavily polluted media -Solar-powered flow measurement station independent ...
NIVUS GmbH

Process temperature: -40 °C - 150 °C
Precision: 1 %
Measuring units: volume flow, flow velocity, thermal output DUC uses the effect of acceleration and decelaration of acoustic signals travelling in a moving liquid. Two ultrasonic clamp-on ...

Process pressure: 0 bar - 16 bar
Process temperature: 0 °C - 90 °C
Volumetric flow rate: 0.8 l/min - 630 l/min
... dosing and meter circuit. The meter circuit indicates the momentary flow rate in the first line of the display and the partial or total quantity in the second line. A dosing circuit ...

Process temperature: -20 °C - 80 °C
Ultrasonic flowmeter TIME DELTA-C This clamp-on portable ultrasonic flowmeter consists of a detector clamped on the pipe (DN13 to 6000 mm depending on detectors) and ...
FUJI ELECTRIC France

Process temperature: -20 °C - 80 °C
Ultrasonic flowmeter TIME DELTA-C Advanced type This clamp-on type portable ultrasonic flowmeter consists of a detector clamped on the pipe (DN13 to 6000 mm depending ...
FUJI ELECTRIC France

Process temperature: -20 °C - 80 °C
Precision: 1.5 %
... type ultrasonic flowmeter M-Flow PW This ultrasonic portable flowmeter consists of a detector clamped on the pipe (DN25 to 1200 mm depending on detectors) ...
FUJI ELECTRIC France

Advanced ultrasonic technology for mobile and highly accurate flow measurements Special features: •Very high measurement accuracy (also bidirectional) •Accurate even at extremely low flow ...

The SeFlow 400 is Sewerin’s single channel portable flowmeter for applications in the municipal water and wastewater sector offering long term stable and precise bidirectional flow measurements in remote ...

Process temperature: -20 °C - 60 °C
Precision: 2.5 %
... waves are dispersed is proportional to the flow rate of the liquid. Hence, the flow rate of the liquid is derived. EPU Clamp-On Ultrasonic Flowmeter No intrusion ...

The DigitalFlow GF868 from Panametrics is a highly versatile, high performance flowmeter capable of many configurations with a large display and ample space for complicated wiring. Several options exist for I/O, including ...
Panametrics, a Baker Hughes business

... Panametrics is a compact and explosion-proof/flame-proof transmitter version of the Panametrics DigitalFlow GF868 flare gas mass flow meter. The DigitalFlow XGF868 is ideally suited for offshore installations ...
Panametrics, a Baker Hughes business

Process temperature: -40 °C - 150 °C
... a liquid clamp-on flow meter designed to be accurate, durable and cost-effective. Rugged and reliable, this meter will remain fixed to your pipe for years to come. Applications The ...
Panametrics, a Baker Hughes business

Process temperature: 0 °C - 200 °C
ISOFLUX™ IFX-F100 Ultrasonic flow meter clamp-on type for fixed installation. Range of sensors for flow measurement in a wide variety of liquids, including and ultra-pure ...
ISOIL Industria Spa

Process temperature: -30 °C - 130 °C
Battery operated Clamp-On Ultrasonic Flow Meter Designed for temporary site installation Easy and fast to install thanks to non-invasive sensors based on transit time ultrasonic ...
ISOIL Industria Spa

Process pressure: 0 bar - 16 bar
Process temperature: 0 °C - 180 °C
ISOFLUX, model IFX-Mx-04, is an energy meter and ultrasonic flow meter which can be used for the measurement of energy consumption for fluids, also other than water in ...
ISOIL Industria Spa

... management. RISONIC compact provides highest precision and reliable measurements in a drift-free flow measurement solution. Drift-free because of the ultrasonic transit time measurement method in which ...

Process temperature: -20 °C - 70 °C
... hydroengineering applications, was developed for ultrasonic flow measurements in filled and partially filled pipes and open channels. Whether for penstock monitoring, turbine and pump efficiency measurements ...
Your suggestions for improvement:

An ultrasonic flow meter uses the propagation of sound waves in a moving fluid to determine flow rate by measuring the time required for the waves to traverse the fluid.
ApplicationsSuch instruments are able to measure the flow of liquids and gases in a pipe.
TechnologiesThese devices consist of a pair of transducers which emit and receive ultrasonic impulses. Waves are emitted both with and against fluid flow. The difference in transit time of the upstream and downstream waves is proportional to the velocity of the fluid. Combined with pipe diameter, this information is used to calculate flow volume.
Meters can be placed within the pipe or clamped to its exterior surface. The latter arrangement is capable of measuring flow in pipes up to four meters in diameter.
Choice will depend on the nature of the fluid, gas or liquid, its temperature, pressure and other characteristics. Other factors include the required degree of accuracy and whether an inserted or clamp-on model is more appropriate. Some are equipped with a digital display.
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining