- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Ultrasonic flow meter
Ultrasonic flow meters
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
USM-RA/RS Series Ultrasonic Gas Meter is a type of electronic meter that adopts TOF (Time of Speed) principle to measure flow velocity of gas medium. Employing advanced ...
Cubic Sensor and Instrument Co.,Ltd
USM-RA/RS Series Ultrasonic Gas Meter is a type of electronic meter that adopts TOF (Time of Speed) principle to measure flow velocity of gas medium. Employing advanced ...
Cubic Sensor and Instrument Co.,Ltd
... -LCA Series Ultrasonic Gas Meter is a type of electronic meter that adopts TOF (Time of Speed) principle to measure flow velocity of gas medium. Employing advanced ultrasonic ...
Cubic Sensor and Instrument Co.,Ltd
Volumetric flow rate: 60, 80, 520, 210, 320 l/min
Process temperature: 60 °C
Process pressure: 1 bar - 4 bar
Absolut wear and maintenance-free ultrasonic technology allows the flowmeter to measure with high precision and independently of the conductivity. It can also be extended with temperature and pressure ...
Volumetric flow rate: 0.1 l/min - 200 l/min
Process temperature: 5 °C - 90 °C
Process pressure: 0 bar - 16 bar
... min (nominal flow rate 3.5 m3/h namely 58 l/min) - model QN 6.0 DN25: 1 to 200 l/min (nominal flow rate 6.0 m3/h namely 100 l/min) Ultrasonic flowmeter using transit ...
Process temperature: -200 °C - 250 °C
Process pressure: 6 bar - 100 bar
Liquid flow meter OPTISONIC 3400 Ultrasonic flowmeter for liquid process applications* Accurate 3-path meter: large dynamic range, maintenance-free, ...
KROHNE Messtechnik GmbH
Process temperature: 180 °C
Ultrasonic flowmeter OPTISONIC 3400 Ultrasonic flowmeter for district heating applications* 3-path meter for thermal energy measurement and heated water * ...
KROHNE Messtechnik GmbH
Process temperature: -40 °C - 120 °C
Ultrasonic clamp-on flowmeter for temporary flow measurement of liquids* Portable, battery-powered meter, for on-site verification of process flows or ...
KROHNE Messtechnik GmbH
Volumetric flow rate: 0 l/min - 1.5 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 100 bar
ES-FLOW® are Volumetric Liquid Flow Meters for very low flow ranges. The instruments operate on a innovative measuring principle, using ultrasound in ...
Volumetric flow rate: 50 l/min - 200 l/min
The SU type ultrasonic flow rate sensor with robot inline design are used to monitor volumetric flow rates, temperature of the medium and offers suitability in water, oil and glycol ...
Process temperature: -50 °C - 100 °C
Process pressure: 100, 50, 4,000 psi
Precision: 0.1 %
... of changing flow dynamics such as blockages upstream of the meter, abnormal flow profiles and liquid hydrocarbons. MeterLink™ Software displays a wealth of predictive diagnostics generated ...
Process temperature: 0 °C - 50 °C
Process pressure: 0 Pa - 1,586,000 Pa
Precision: 2, 5 %
• Economical Ultrasonic Flow Meter for Water Service • DN 32 to 200 (2 to 8") Flanges • Battery Powered • Displays Flow Rate and Total • Extended ...
OMEGA
Volumetric flow rate: 15 m³/h - 3,600 m³/h
Process temperature: 0 °C - 200 °C
Process pressure: 0 bar - 40 bar
The SITRANS FUS380 is a battery or mains supply powered 2-path flowmeter designed for numerous standard applications. It can be used in all utility applications for water flow monitoring. The SITRANS ...
Siemens Process Instrumentation
Volumetric flow rate: 15 m³/h - 36,000 m³/h
Process temperature: 0 °C - 200 °C
Process pressure: 0 bar - 40 bar
... modules include MODBUS RTU protocol. The SITRANS FUE380 flowmeter consists of a sensor and transmitter. For details and information about the transmitter, see SITRANS FUS080. The flowmeter can ...
Siemens Process Instrumentation
Volumetric flow rate: 100 m³/h - 78,000 m³/h
Process temperature: -20 °C - 200 °C
Process pressure: 0 bar - 40 bar
SITRANS F US SONOKIT offers a simple, accurate alternative to traditional flowmeters as it can be retrofitted onto existing pipelines. Being a transit time based ultrasonic flowmeter,SITRANS F US SONOKIT ...
Siemens Process Instrumentation
Volumetric flow rate: 0 l/h - 50 l/h
Process temperature: -10 °C - 45 °C
Process pressure: 3 bar - 16 bar
The flow meter DulcoFlow® reliably measures pulsating flows in the range above 0.03 ml/stroke based on the ultrasound measuring principle. The flow meter ...
Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic ...
Pulsar Measurement
Process temperature: -23 °C - 60 °C
Process pressure: 0 psi - 10 psi
Precision: 2 %
Gaining flow measurement inside a pipe can sometimes be tricky. The DFM 6.1 Doppler Flow Meter works as a non-contacting, clamp-on flow meter to offer ...
Pulsar Measurement
Process temperature: -20 °C - 50 °C
... Pulsar Flow Monitor is designed to be combined with the FlowPulse Sensor, a dedicated wall-mounted device that gives an instant indication to pipe flow. The unit is ideal for fixed installations, ...
Pulsar Measurement
Volumetric flow rate: 80 l/h - 11,000 l/h
Process temperature: -18 °C - 50 °C
Process pressure: 10,000, 15,000 psi
... flowmeter is replacing intrusive flow measurement techniques in other designs, introducing a step change in CIMV technology. The ultrasonic flowmeter fires an ultrasonic ...
CAMERON
Process temperature: -30 °C - 70 °C
Cost-efficient alternative to conventional EMFs/mag meters. For continuous flow measurement in slight to heavily polluted media in full pipes
NIVUS GmbH
Process temperature: -30 °C - 80 °C
For ultrasonic flow measurement of slight to heavily polluted media in part filled and full pipes and channels. Best possible results even under difficult conditions. -Very high accuracy flow ...
NIVUS GmbH
Process temperature: -20 °C - 70 °C
... velocities with low flow levels. Dynamic hydraulic models for various channel shapes based on varying filling levels enable accurate detection of the real flow rate. Ultrasonic Flow ...
NIVUS GmbH
Volumetric flow rate: 0 m³/h - 7.3 m³/h
Process temperature: 1 °C - 60 °C
Precision: 1.5, 3 %
The E-Series® Ultrasonic Plus meter utilizes ultrasonic transit-time technology to measure cold potable water and incorporates an integrated valve into the lay length of the meter. ...
Badger Meter
Process temperature: -20 °C - 480 °C
Process pressure: -10,000 Pa - 10,000 Pa
... is a high temperature ultrasonic Flowmeter independently developed by Cubic-Ruiyi. Based on the TOF (Time of Flight) principle of ultrasonic wave, the gas flow rate in ...
Cubic Instruments (Wuhan) Ltd.
Volumetric flow rate: 3 m³/h - 3,200 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 200,000 Pa
Introduction BF-3000 Ultrasonic Biogas Flowmeter can be commonly used with various industrial gas streams(biogas, natural gas, air, etc.), but with special design to enable it withstand the wet and corrosive ...
Cubic Instruments (Wuhan) Ltd.
Volumetric flow rate: 3 m³/h - 3,200 m³/h
Process temperature: -10 °C - 40 °C
Process pressure: 0 Pa - 200,000 Pa
Introduction BF-3000B Ultrasonic Biogas Flowmeter is based on technology combination of pressure differential and ultrasonic transit time differential measurement method. With a bypass ...
Cubic Instruments (Wuhan) Ltd.
The SeFlow 400 is Sewerin’s single channel portable flowmeter for applications in the municipal water and wastewater sector offering long term stable and precise bidirectional flow measurements in remote ...
Process temperature: -20 °C - 60 °C
Precision: 2.5 %
... waves are dispersed is proportional to the flow rate of the liquid. Hence, the flow rate of the liquid is derived. EPU Clamp-On Ultrasonic Flowmeter No intrusion ...
... are dispersed is proportional to the flow rate of the liquid. Hence, the flow rate of the liquid is derived. Features EPU Clamp-On Ultrasonic Flowmeter No intrusion ...
UDM 300 - Advanced ultrasonic technology for mobile and highly accurate flow measurements Special features: ■ Very high measurement accuracy (also bidirectional) ■ Accurate even at extremely low flow ...
The DigitalFlow GF868 from Panametrics is a highly versatile, high performance flowmeter capable of many configurations with a large display and ample space for complicated wiring. Several options exist for I/O, including ...
Panametrics, a Baker Hughes business
... Panametrics is a compact and explosion-proof/flame-proof transmitter version of the Panametrics DigitalFlow GF868 flare gas mass flow meter. The DigitalFlow XGF868 is ideally suited for offshore installations ...
Panametrics, a Baker Hughes business
Process temperature: -40 °C - 150 °C
... a liquid clamp-on flow meter designed to be accurate, durable and cost-effective. Rugged and reliable, this meter will remain fixed to your pipe for years to come. Applications The ...
Panametrics, a Baker Hughes business
Process temperature: 0 °C - 160 °C
Precision: 1 %
... quick install, high performance • - Battery powered last for over 14 hours continuous opération • - Thickness measurement achievable UFM sériés Handheld Ultrasonic Flowmeter is mainly ...
Process temperature: -20 °C - 80 °C
Ultrasonic flowmeter TIME DELTA-C This clamp-on portable ultrasonic flowmeter consists of a detector clamped on the pipe (DN13 to 6000 mm depending on detectors) and ...
FUJI ELECTRIC France
Process temperature: -20 °C - 80 °C
Ultrasonic flowmeter TIME DELTA-C Advanced type This clamp-on type portable ultrasonic flowmeter consists of a detector clamped on the pipe (DN13 to 6000 mm depending ...
FUJI ELECTRIC France
Process temperature: -20 °C - 80 °C
Precision: 1.5 %
... type ultrasonic flowmeter M-Flow PW This ultrasonic portable flowmeter consists of a detector clamped on the pipe (DN25 to 1200 mm depending on detectors) ...
FUJI ELECTRIC France
Process temperature: 0 °C - 100 °C
Process pressure: 25 bar
Precision: 2 %
... Description The electromagnetic insertion sensor MS3810, flow meters, energy meters, ultrasonic flowmeters, and industrial automation systems have been ISOIL Industria‘s ...
ISOIL Industria Spa
Process temperature: -10 °C - 60 °C
Precision: 3, 0.5, 1 %
Repeatibility: 0.15 %
... records. Description The ultrasonic flow meter clamp-on for fixed installation IFX-F100, flow meters, energy meters, ultrasonic ...
ISOIL Industria Spa
Process temperature: -30 °C - 130 °C
Precision: 1, 3, 0.5 %
Repeatibility: 0.15 %
... the Modbus. Description The portable clamp-on flow meter IFX-P210, flow meters, energy meters, ultrasonic flowmeters, and industrial ...
ISOIL Industria Spa
Process temperature: -40 °C - 150 °C
Precision: 1 %
Measuring units: volume flow, flow velocity, thermal output DUC uses the effect of acceleration and decelaration of acoustic signals travelling in a moving liquid. Two ultrasonic clamp-on ...
KOBOLD Messring GmbH
Permanent A/C powered flow meter (controller only) Highly accurate flow measurement using ultrasonic sensor technology Simple menu-driven system. Provides ...
Hach
Process temperature: 80 °C
The most advanced portable ultrasonic flow meter is available. Incorporationg over 30 years of field experience, the UF 801-P is the ideal ultrasonic portable flow ...
ULTRAFLUX
Your suggestions for improvement:
An ultrasonic flow meter uses the propagation of sound waves in a moving fluid to determine flow rate by measuring the time required for the waves to traverse the fluid.
ApplicationsSuch instruments are able to measure the flow of liquids and gases in a pipe.
TechnologiesThese devices consist of a pair of transducers which emit and receive ultrasonic impulses. Waves are emitted both with and against fluid flow. The difference in transit time of the upstream and downstream waves is proportional to the velocity of the fluid. Combined with pipe diameter, this information is used to calculate flow volume.
Meters can be placed within the pipe or clamped to its exterior surface. The latter arrangement is capable of measuring flow in pipes up to four meters in diameter.
Choice will depend on the nature of the fluid, gas or liquid, its temperature, pressure and other characteristics. Other factors include the required degree of accuracy and whether an inserted or clamp-on model is more appropriate. Some are equipped with a digital display.
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining