The KOBOLD liquid level switch NWS is designed as a 2 and 3-wire switch and can be universally used in vessels and pipelines. The NWS operates on the tuning fork principle in air at resonance frequency. A piezoelectric crystal is used for excitation of oscillations and for monitoring the actual oscillation frequency.
When the fork is immersed in liquid, the frequency changes: this change is detected electronically and the output signal is changed. The NWS operates as a 2-wire switch in series with the load. The simple electronic switch is operated by the liquid. The NWS can also be connected to a PLC through a third terminal.
Contact: 1 electronic switch
Connection:
G ¾, G1 male thread, ¾" NPT, 1" NPT male thread,
Tri-Clamp® DIN 32676, hygenic DIN 11851,
DIN-flange DN25, DN50, ANSI-flange 1", 2"
Material: stainless steel 1.4404