- Electricity - Electronics >
- Electronic Component >
- Amplifier
Amplifiers
Frequency: 0 Hz - 1,500,000 Hz
... gauge bridge amplifier is a differential high speed front-end amplifier with high precision. Strain gauges can be connected to the measuring bridge in full bridges, half bridges or ¼ bridge construction. Among its main ...
Frequency: 0 Hz - 20,000,000 Hz
... The EL-LNA-2 is a 2-channel amplifier manufactured by Elsys. It is designed for any 3rd party data acquisition system. The amplifier offers an option between two gain stages of x10 and x100, both with a full bandwidth ...
Voltage: 24, 110, 220 V
Current: 25 mA
... These units are very versatile as they can be used with all NAMUR, NPN and PNP sensors, functioning with relay ON or OFF load with a timing function in both states. Furthermore they have a programmable time scale from 0,03 seconds to 12 minutes. PROGRAMMABLE ...
Voltage: 12, 110, 220 V
Current: 50 mA
... These instruments are made up of a transformer an amplifier and a transistor, a rectifying circuit and one or two output relays with changeover contacts, respectively in the ALNC and ALN2 types. They are used to supply with a stabilized ...
Voltage: 12, 110 V
Current: 25 mA
... These instruments are made up of a transformer an amplifier and a transistor, a rectifying circuit and one or two output relays with changeover contacts, respectively in the ALNC and ALN2 types. They are used to supply with a stabilized ...
Voltage: 230, 110, 24 V
Current: 6 A
Frequency: 60, 50 Hz
... The VNR21.22 control units are designed as interface for conductive level probes SL series. These electronic units are used to control liquids that have a minimum electrical conductivity of 1 S. The system is based on measurement of the conductivity ...
Voltage: 230, 24 V
Current: 5 A
Frequency: 60, 50 Hz
The VNR2300 control unit was designed as low cost interface for conductive level probes. These electronic units are used to control liquids that have a minimum electrical conductivity of 10 S. The system is based on measurement of the conductivity of ...
Voltage: 24, 230 V
Current: 5 A
Frequency: 60, 50 Hz
... This control unit with double measuring channels was designed as low cost interface for conductive level probes and is used to control liquids that have a minimum electrical conductivity of 8 µS. The system is based on measurement of the conductivity ...
Voltage: 24 V - 260 V
Current: 300 mA
Frequency: 50, 60 Hz
... OPTOCOUPLED STATIC OUTPUTS • 1 or 2 channels • General Features: These units allow to amplifiy signals from NAMUR sensors or contacts. Each output is electrically insulated from each other, from power supply and from all the inputs. It is possible ...
BDC ELECTRONIC S.r.l.
Voltage: 24 V - 260 V
Current: 5 A
Frequency: 50, 60 Hz
... RELAY OUTPUT • 1 or 2 channels • General Features: These units allow to amplifiy signals from NAMUR sensors or contacts. The relay outputs have changeover N.O. + N.C. contacts electrically insulated from each other, from power supply and from all ...
BDC ELECTRONIC S.r.l.
Voltage: 24 V - 260 V
Current: 300 mA
Frequency: 50, 60 Hz
... • OPTOCOUPLED STATIC OUTPUT • 1 Timed channel General Features: These units allow to amplify signals from NAMUR sensors or contacts. The delay time and hold time respect the input signal are adjustable through potentiometers on the front panel. ...
BDC ELECTRONIC S.r.l.
Voltage: 7, 10, 100 V
Frequency: 10 Hz - 100,000 Hz
... Single-ended and differential inputs AC coupled input Powered by SRS lock-in amplifiers High common mode rejection The SR550 Voltage Preamplifier is designed to work with any SRS lock-in amplifier. Preamplifiers provide ...
Stanford Research Systems
Power: 1 W
... without Cooling Fans Model Specific and General Configurations AC and DC Power Supply Options and Control Cable Interfaces Amplifier Mating Control Connector Interfaces Thermal Gaskets Included ...
Pasternack Enterprises, Inc.
Voltage: 10, 5 V
Current: 0 mA - 20 mA
... Strain Gauge (SG) Measuring Amplifier for the Conversion of SG-based Sensor (e.g. Force and Torque Sensors or Load Cells) Output Signals to normed Voltage Signals of ±5V, ±10V, 0/4 ... 20 mA, 10 ±10 mA or 12 ±8 mA for the direct Connection ...
Lorenz Messtechnik
Voltage: 100 V - 240 V
Frequency: 60, 50 Hz
... The HD2050.20 is a digital signal amplifier, designed to work with HD2050 and HD2050.30 sources to obtain from these maximum acoustic performances. The HD2050.20 amplifier incorporates a white / pink noise generator ...
Frequency: 1,200 MHz - 1,700 MHz
... ROGER™ GNSS Amplifier & Splitter is a combined signal splitter and line amplifier that can transmit amplified signal to up to three separate repeater units. Amplifier has a gain of +16dB at the GPS L1/L2/GLONASS/GALILEO/BEIDOU ...
Roger-GPS Oy
Current: 4 mA - 20 mA
... in a more efficient and productive way. Reading its signal is difficult, but with an amplifier the job is made simpler, easier and more efficient. The amplifier is housed in an ABS enclosure allowing easy installation ...
Datum Electronics
Voltage: 10 V
Current: 4 mA - 20 mA
... series is suitable for use in strain gauges bridge like in 24 bit acquisition circuit, with a programmable gain. The digital amplifier is also utilized in 3 analog outputs, toward a supervision unit. The unit functions through allowing ...
ASA-RT s.r.l.
Current: 0 mA - 0 mA
... Newtons4th Ltd. is a transimpedance amplifier (TIA) module which are the compatible unit for systems having a superior impedance designed for analyzing the system by measuring the current flow applying all the test and amplifier ...
Newtons4th Ltd.
Power: 80, 8 W
Frequency: 2 MHz
... Computer controlled OVERVIEW ORPHEUS‑ONE is a collinear optical parametric amplifier (OPA) of white‑light continuum pumped by femtosecond Ytterbium based laser amplifiers and focused on mid‑infrared wavelengths generation. In ...
Light Conversion
Voltage: 18 V - 240 V
Power: 18 W
Frequency: 45 Hz - 65 Hz
... distribution amplifier. Cost-Effective Capacity Microsemi's TSC 4340A fiber optic distribution amplifier provides a cost effective upgrade path, enabling networks to multiply the output from one UTCG to 8. For example, ...
Microsemi
Voltage: 2.5 V
Frequency: 20 kHz - 220 kHz
... Hinds’ Exicor Systems the Signaloc is now availaible for anyone who can use a dual-phase, analog, single frequency lock-in amplifier. You choose the frequency – any frequency between 20-200 kHz. You choose 1f or 1f and 2f demodulation ...
Voltage: 115, 230, 24 V
... ISG-A series: Single channel opto sensors with automatic setting, providing high sensitivity over the full range. ISG-N series: Single channel opto sensors with manual setting, providing high range, high power and dust immunity. ...
Pantron Instruments GmbH
... The Fiber Optic Amplifier is a photoelectric sensor from the FX Series. It is designed with a standardized DIN rail fiber optic for mounting power supplies. This device comes with a Teach-in (FX4) or trimmer sensing adjusting (FX3). ...
Micro Detectors
Frequency: 250 MHz
... series is a new generation of transimpedance, AC or DC coupled amplifiers. They are designed to operate with either biased or non-biased VIGO detectors. AIP is „all‑in-one” device - an amplifier is integrated with a fan ...
Vigo Photonics
Voltage: 12, 20 V
Amplifier for Simplebus 2 video systems. Regenerates the riser signal regarding the video component. Complete with microcontroller for optimum operation management. For its use, follow the indications given in the technical documentation. ...
Voltage: 20 V - 253 V
Current: 0 mA - 20 mA
... The TV 22 GL isolation amplifier is used for galvanic isolation and amplification of DC signals (mA). Description Input and output are galvanically isolated with a high degree of isolation. The integrated high-efficiency electronic ...
AFRISO-EURO-INDEX
Frequency: 0.15 MHz - 240 MHz
Current: 1.2 A - 9.7 A
Frequency: 8 GHz - 15 GHz
... to Point and SatCom Data Links - Ideal for Airborne & UAV Use - Compact Laboratory Amplifier - Radar Description The MPM is an efficient, low noise amplifier consisting of a high gain solid-state driver (MMIC) ...
Voltage: 12 V - 24 V
Current: 50 mA
... High Performance Single/Dual Digital Display Fiber Optic Amplifiers The BF5 series fiber optic amplifiers are available in single and dual display models. The units feature 5 different response speed settings, for ...
Autonics
Voltage: 1.9 V - 2.5 V
Power: 1 W
Frequency: 860 MHz - 960 MHz
... The CMX90A003 is a two-stage, fully matched MMIC PA delivering +29.5 dBm of saturated power for use in the 860 – 960 MHz frequency range, applicable to license-free bands. The device is optimised for efficiency at low collector voltages of 1.9 – 2.5 ...
CML Microcircuits
Voltage: 100 V - 250 V
Current: 40 mA - 120 mA
Power: 3, 30 W
... Bipolar Operation for Piezoelectric Patch Transducers • OEM module for piezoelectric DuraAct patch transducers • Compact: 87 mm × 50 mm × 21 mm ...
PI Ceramic GmbH
the best suppliers
Subscribe to our newsletter