- Electricity - Electronics >
- Switch and Relay >
- Closed circuit disconnect switch
Closed circuit disconnect switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 5,000 A
VAC: 145, 420, 245, 550 kV
... provide excellent electrical conductibility. The parallel connection lowers circuit resistance. Some other noteworthy features of the GW54 disconnector are: • Minimized contact resistance • All joints connected ...
Primary current: 63 A - 630 A
... 3NJ6 switch disconnectors with fuses feature an integrated switching device with single or double interruption capacity. They are especially well-suited for applications where large numbers of cable runs for power distribution need to ...
Primary current: 16 A - 1,600 A
VAC: 120 V - 600 V
... accessories Application of Enclosed Rotary Disconnect Switch KINRED enclosed circuit breaker disconnect switches have diverse use including industrial control panels, ...
Wenzhou Jinhong Electrical Appliance
Primary current: 16 A - 125 A
VAC: 440 V
... Lockable Disconnect Switch Manufacturer in China The lockable feature of the disconnect switch allow authorized technicians to secure units in the open or closed position ...
Wenzhou Jinhong Electrical Appliance
Primary current: 200 A
... Manual disconnect switch is operated by hand. It requires physical interaction to switch the ON/OFF position. They are specifically designed with load-breaking capability. Meaning, they can safely interrupt ...
Wenzhou Jinhong Electrical Appliance
Primary current: 40 A - 1,600 A
VAC: 500, 1,000, 690 V
... Installation : Inside and outside Main uses : Heavy industries (mines, quarries, sugar, cement, paper, iron and steel ...) Advantages : Resist to corrosion, acids, salts, organic solvents, lubricating oils and greases, fuel oils, U.V. rays : no discoloration, ...
Cefem Group
Primary current: 40 A - 800 A
VAC: 500 V - 1,000 V
... Installation : Inside and outside Main uses : Food and beverage, pharmaceutical industries with restrictive hygienic requirements. Advantages : A fully welded and robust enclosure which is 2 mm thick stainless steel. Our range design combines reliability ...
Cefem Group
Primary current: 40 A - 1,600 A
VAC: 690, 500, 1,000, 400 V
... Installation : Inside and outside Main uses : Industry in general (railway, mines, quarries, sugar, cement, paper, iron and steel, car, food and beverage industries...). Advantages : A fully welded and robust enclosure which is 2 mm thick ...
Cefem Group
Primary current: 25 A - 630 A
VAC: 400 V
... The repair switch is an enclosed main switch with an emergency-off function for an individual electrical consumer. Its installation in the immediate vicinity of the motor or of the electrical consumer ...
Primary current: 16 A
VAC: 400 V
Taken into the account in the design of these devices are the VDE provisions of DIN EN 60204 Part 1, section 7.5 (protection against automatic restarting when power is restored following a power cut)
Primary current: 16 A - 160 A
... REFERENCE STANDARDS EN 60947-3 Low voltage switchgear and controlgear. Part 3: Switches disconnectors, switch-disconnectors and fuse-combination unit. EN 60529 Specification for degrees of protection provided by ...
SCAME PARRE S.p.A.
Primary current: 5,000, 3,150, 4,000, 2,000 A
VAC: 252, 363, 550 kV
... GW27-252/363/550 HV disconnectors are developed by Pinggao based on the same kind of domestic and foreign products, with rated voltage from 110 kV to 550 kV and rated current from 2000 A to 5000 A. This series of products are three-column ...
Primary current: 25 A - 100 A
... opening amplitude and connection terminals are amply sized. - Degree of protection: up to IP 66 - For 25A to 100A size switches - Cable entries with pre-formed knockouts - Tamper-proof cover with padlockable handle - Recessed area ...
... Switch-disconnectors installed in industrial facilities are often exposed to environment pollution and accidental impacts. Aluminium enclosures are characterised by good resistance to chemicals including hydraulic oils, ...
GAVE ELECTRO
Primary current: 12 A - 80 A
... . Fully manufactured in cast 304 stainless steel Dimensions (H x W x D): 165 mm x 120 mm x 117 mm Equipped with disconnect switch from WEG, Schneider or ABB brands and two cable glands M25 (14-17) ...
Primary current: 32, 12 A
VDC: 600, 1,000 V
... materials • Lockable handle in the “OFF” position for added safety • Compact, ergonomic design • High terminal accessibility • Cover interlock with knob in "ON" position These DC isolator switches are ideal for ...
BREMAS BETTER SWITCHES
Primary current: 40, 25 A
VAC: 240, 400, 415 V
... 60947-3 Cable Area to Switch Terminal (only Cu) (mm2) / Bolt size - 1.5-16 Color - Yellow / Red Enclosure - M2 Enclosure Type - Polycarbonate IP Rating - 66 Operation - Front-operated Switch type - Load Break ...
KATKO
Primary current: 250 A
VAC: 1,000 V
... Switch – disconnectors on-load available from 125A up to 1000A with drive mechanism in side and from 1250A up to 2000A with drive mechanism on front, are in 6P or 8P versions. Rated breaking current of up to 8 times the ...
Telergon
Primary current: 20 A - 80 A
... The die-cast enclosed family of switch disconnectors provides the user with a product that will withstand a good deal of abuse. With sealing to IP66 these products can safely be placed in environments where resistance to impacts, moisture ...
Craig & Derricott
Primary current: 40 A - 1,600 A
VAC: 415 V
... EN60947/IEC947 the range of‘EFI’ Local Disconnector switches, comprise of highrupturing, quick make and break contacts. The ‘EFI’ range can be used for motor isolating dutiesfor D.O.L and star-delta motors. Switch units ...
Primary current: 20 A
VAC: 400 V
... Specifications • Handle Type Enclosed / Interlocked Handle • Lockable Y • Nema Rating 4X • UL Current Rating (A) 20.00 • Temperature Range °C -40 to +40°C • Number of Poles 3P • IP Rating IP66 • Cable sizes (AWG) 20-8AWG • Cable size ...
IMO Precision Controls Limited
Primary current: 16 A
... 1 Flush-mounting dimensions - - No. discs - - Rated impul. withstand voltage - 4 Function Apparatus Control - One way switches ...
Primary current: 25, 16 A
VAC: 400, 690 V
... temperature use:-40℃≤Ta≤55℃ Degree of protection:IP65 Rated current:16(690V AC)/25A(400V AC) Terminal:2*6mm2 Capacity of switch:AC 3 230V 25A 400V 25A 500V 20A 690V 16A Material of enclosure:Anti-static glass fibre reinforced polyester ...
Primary current: 25 A - 30 A
... Whether for cleaning, maintenance, or repair—with switch disconnectors in types of protection Ex d, Ex tb and Ex tD, you safely disconnect machines and equipment without the need for specially trained staff. Supporting ...
... ‘TECHNOR® selector switches to be installed in explosion-proof enclosures for potentially explosive atmospheres zones 1 & 2 (gas), 21 & 22 (dust). This range includes switches, changeover switches, or selector switches’. PSRC Zone 1-21, ...
Primary current: 630 A
VAC: 24, 36 kV
... Insulated medium voltage overhead switch-disconnecter with SF6 and controlled manually or remotely with up to 36 kV. Installation on an overhead network. The NOGARIS OP overhead switch-disconnecter is installed ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group