Vertical disconnect switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 0 A - 5,000 A
VAC: 36,000 V - 800,000 V
... pantograph disconnectors — minimal mounting footprint, scissors-type busbar connection, diagonal or parallel arrangements, optional self-interlocking, robust for high mechanical and thermal loads
Siemens Energy – Power transmission
Primary current: 0 A - 4,000 A
VDC: 1,500 V
... Product Overview
The ZGW1 is an outdoor double‑column
vertical‑opening DC
disconnector designed for urban rail transit systems. Rated voltage: 1.5 kV. It provides reliable isolation and a mechanically robust ...
Sieyuan Electric Co., Ltd
Primary current: 1,200 A - 4,000 A
VAC: 25 kV - 550 kV
... CGVB-05 vertical break disconnector is designed to reduce phase spacing to a minimum. The jaw end of the switch is supported by one fixed insulator. The hinge end consists of two insulators, one fixed, ...
Primary current: 3,150 A
VAC: 800 kV
... and minimal maintenance The horizontal knee disconnector requires the smallest spaces in both horizontal and vertical directions, suitable for substation with small installation area. The DDK800 disconnector ...
Primary current: 160 A
VAC: 690 V
... indicator for switch door position - optional Safe on load connection/disconnection in accordance with IEC 60947-3 Applications House incoming units Meter distribution units Switch boards for industrial ...
Mersen - Electrical Power
VAC: 0 V - 263,000 V
... following two structural forms: 1. GW16-363 / 5000 type isolation switch is a single column, vertical fracture, single-arm folding clamp type 2. GW17-363 / 5000-type isolation switch is a double ...
Primary current: 20,000, 31,500, 63,000 A
VAC: 24 kV
... is depending on type specified. All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 20,000, 31,500, 63,000 A
VAC: 38.5 kV
... is depending on type specified. All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 630, 1,600, 2,500, 4,000 A
VAC: 12 kV
... is depending on type specified. All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 2,000 A - 5,000 A
VAC: 126 kV - 363 kV
... Insulator double row ball bearings
• Adjustable open and close position stops
Vertical Knee
Disconnector (
Vertical Knee Break Isolator) is a high-voltage
disconnector used in ...
Primary current: 2,000 A - 5,000 A
VAC: 126 kV - 363 kV
... row ball bearings
• Adjustable open and close position stops
Horizontal Knee
Disconnector (Horizontal Knee Break Isolator) is a high-voltage
disconnector used in air-insulated substations (AIS) to provide a ...
... the philosophy of the company, “continuous development and innovation”, Pronutec presents the latest generation of vertical fuse switches NH 1/2/3, TRIVER+. This range aims to meet our customers present and future requirements. FULLY ...
PRONUTEC S.A.U.
Primary current: 0.06 A - 2 A
VAC: 8.3 kV - 170 kV
... standards for this type of equipment. Available models include the standard single pole hookstick, Regulator Bypass Switch and Tandem Transfer Switch. ...
Southern States LLC
Primary current: 160, 250, 400, 630 A
... FUSE SWITCH-DISCONNECTORS – VERTICAL DESIGN Used for protection of electrical grid from short-circuiting and overloading. Intended for installation on collectors. Easily installed, take up little free space on the ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.