Primary current: 2,000 A
VAC: 145, 126 kV
... Center break disconnector with smaller footprint and high reliability Hitachi Energy’s DDHV – ‘V’ type center break disconnector is a compact, reliable and easy-to operate substation equipment. Suitable for applications ...
Hitachi Energy
Primary current: 200 A - 3,150 A
VAC: 0 kV - 420 kV
... The horizontal centre break disconnectors has a rated voltage that goes up to 420 kV. Minimum rated current is 200 up to 3150 amps. Manual and mechanized working systems could be given. Mechanical interlocks between principle ...
CG Power Systems
Primary current: 5,000, 2,000, 3,150 A
VAC: 363, 550, 252 kV
... 363/550 HV disconnectors are developed by Pinggao based on the same kind of domestic and foreign products, with rated voltage from 110 kV to 550 kV and rated current from 2000 A to 5000 A. This series of products are three-column horizontal-rotation ...
Henan ping high electric co., LTD.
Primary current: 20,000, 31,500, 63,000 A
VAC: 24 kV
... is depending on type specified. All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 20,000, 31,500, 63,000 A
VAC: 38.5 kV
... is depending on type specified. All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 630, 1,600, 2,500, 4,000 A
VAC: 12 kV
... is depending on type specified. All switches are type-tested according to EN 62271-102 and are suitable either for vertical mounting (900operating angle) or horizontal mounting (1100 opera-ting angle).For each switch ...
Fritz Driescher & Söhne GmbH
Primary current: 2,000 A - 4,000 A
VAC: 40.5 kV - 252 kV
... Transformer isolation
·Circuit breaker isolation
·Busbar sectionalizing
The center break
disconnector is one of the most common
disconnectors in 72.5 kV to 245 kV air-insulated substations, offering a reliable ...
Dowei Electric
Primary current: 1,250 A - 5,000 A
VAC: 126 kV - 363 kV
... Cast Aluminum Contact Base
• Copper and Silver Moving Contact
• Robust, Seamless Steel Pipe Base
Double Break
Disconnector (Double Break Isolator) is a high-voltage switching device used in transmission and distribution substations ...
Dowei Electric
Primary current: 2,000 A - 5,000 A
VAC: 126 kV - 363 kV
... Insulator double row ball bearings
• Adjustable open and close position stops
Horizontal Knee
Disconnector (
Horizontal Knee Break Isolator) is a high-voltage
disconnector used ...
Dowei Electric
VAC: 400 V
VDC: 23 V
... cutout KVL - horizontal fuse- switch disconnectors with different sizes can be combined together and form uniform cover cutout. The new assortment contains four cover support levels at 32, 60, 70 and 90 ...
Primary current: 2 A - 630 A
... The Three pole horizontal design fuse switch disconnector BTHC has been designed in accordance with the latest safety and operating requirements and it complies with the IEC 60947-3 standard. The ...
Primary current: 20,000 A - 40,000 A
VAC: 0 V - 245 V
... operations are accomplished in SF6, eliminating open air arcs. The horizontal interrupter circuit switcher is available with (Model CSH-B) or without (Model CSH) an integral vertical break switch. The design of the CSH ...
Southern States LLC
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group