Motorized disconnector GW10
manualhigh-voltage3-pole

Motorized disconnector - GW10 - Dowei Electric - manual / high-voltage / 3-pole
Motorized disconnector - GW10 - Dowei Electric - manual / high-voltage / 3-pole
Add to favorites
Compare this product

Characteristics

Type
manual, motorized
Voltage level
high-voltage
Number of poles
3-pole
Electrical characteristics
AC, grounding, three-phase
Construction
vertical
Assembly
overhead
Applications
industrial, for photovoltaic applications
Other characteristics
outdoor, blade, pantograph
Certifications
IEC
Primary current

Max.: 5,000 A

Min.: 2,000 A

VAC

Max.: 363 kV

Min.: 126 kV

Description

• IEC 62271, ANSI/IEEE Std C37, NEMA
• ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA
• Seismic design, ETGI-1.020, IEEE Std 693, NCh2369
• Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1
• High altitude correction per IEC 62271 & IEEE C37, ~ 5000m
• Copper and silver moving contact
• Insulator double row ball bearings
• Adjustable open and close position stops

Vertical Knee Disconnector (Vertical Knee Break Isolator) is a high-voltage disconnector used in outdoor substations to provide visible electrical isolation of equipment after the associated circuit breaker has interrupted the current. It features a hinged "knee" joint that folds upward or downward during operation, making it suitable for substations where horizontal space is limited.

Working Principle
The vertical knee disconnector consists of two conducting arms connected by a hinged knee joint.

·Closed position: The arms are aligned, forming a continuous electrical path between the terminals.
·Open position: The operating mechanism bends the knee joint, causing the upper arm to move upward (or downward, depending on the design) and creating a visible air gap for isolation.

Like all disconnectors, it is not designed to interrupt load current or fault current. The associated circuit breaker must first de-energize the circuit.

Normal Operating Sequence
1.Open the circuit breaker.
2.Verify the circuit is de-energized.
3.Open the vertical knee disconnector.
4.Close the earthing switch if maintenance is to be performed.

Main Components
·Fixed contacts
·Upper and lower conducting arms
·Hinged knee joint
·Post insulators
·Operating linkage
·Motor-operated or manual operating mechanism
·Base frame
·Position indicator
·Auxiliary switches

Features
·Foldable knee-joint mechanism provides a compact operating movement.
·Visible isolation gap enhances maintenance safety.
·Suitable for substations with limited horizontal clearance.
·High mechanical reliability.
·Available with manual or motor operation.
·Designed for outdoor service in air-insulated substations (AIS).

Typical Voltage Ratings
·72.5 kV Distribution and sub-transmission
·110 kV Transmission substations
·132 kV Utility transmission
·145 kV High-voltage substations
·220 kV Transmission systems
·330 kV Extra-high-voltage substations
·400 kV EHV transmission

Advantages
·Compact design requiring less horizontal space.
·Clear visible isolation for operator safety.
·Reliable mechanical operation.
·Well suited to constrained substation layouts.
·Long service life with relatively low maintenance.

Limitations
·Cannot interrupt load or fault current.
·Must only be operated after the circuit breaker has opened.
·Mechanically more complex than some conventional disconnector designs.

Applications
Vertical knee disconnectors are widely used for:
·Air-insulated substations (AIS)
·Transmission line isolation
·Transformer isolation
·Circuit breaker isolation
·Busbar sectionalizing
·Industrial and utility substations
·Installations with limited horizontal clearance

Typical Applications by Voltage
·72.5–145 kV: Distribution and sub-transmission substations with limited space.
·220–400 kV: High-voltage transmission substations where compact layouts are required.
Industrial power systems: Isolation of transformers, circuit breakers, and busbars.

The Vertical Knee Disconnector combines reliable visible isolation with a compact operating mechanism, making it an effective choice for air-insulated substations where space constraints make traditional horizontal-opening disconnectors less suitable.