- Electricity - Electronics >
- Switch and Relay >
- Motorized disconnect switch
Motorized disconnect switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
VAC: 25,000 V
VDC: 1,500, 750, 85, 3,000 V
... 3,000VDC and 25kVAC. Our standard On-Board disconnector range is rigorously engineered to meet your technical specifications in different configurations (Disconnector, Change-over, Grounding). Mersen has a switch solution ...
Primary current: 2,000 A - 4,000 A
VAC: 40.5 kV - 252 kV
... • IEC 62271, ANSI/IEEE Std C37, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • ...
Dowei Electric
Primary current: 1,250 A - 5,000 A
VAC: 126 kV - 363 kV
... • IEC 62271, ANSI/IEEE Std C37, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • ...
Dowei Electric
Primary current: 2,000 A - 5,000 A
VAC: 126 kV - 363 kV
... • IEC 62271, ANSI/IEEE Std C37, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • ...
Dowei Electric
... flow of power is frequently included. KINRED motor disconnect switches are important parts of electrical systems that guarantee the security of people and machinery. KINRED motor disconnect switch ...
Primary current: 400 A
VAC: 15 kV
... conditions in compliance with EN 62271-1. These Driescher indoor switches are specially designed for railway applications. They meet the specifications according to the EN 50152-2.The 1-pole switches are designed for ...
Fritz Driescher & Söhne GmbH
Primary current: 630 A
VAC: 15 kV
... conditions in compliance with EN 62271-1. These Driescher indoor switches are specially designed for railway applications. They meet the specifications according to the EN 50152-2.The 1-pole switches are designed for ...
Fritz Driescher & Söhne GmbH
Primary current: 630 A
VAC: 27.5 kV
... This is a single pole indoor switch disconnecter used for railway lines with H 22-1B,Un 27.5 Kv ...
Fritz Driescher & Söhne GmbH
Primary current: 0 A - 6,300 A
VAC: 3,600, 1,800 V
... Sécheron SW-type off-load disconnectors come in a wide range of configurations and with optional features to meet the needs of all railway applications. Our disconnectors ensure the safe isolation of the equipment powering ...
Secheron
Primary current: 12, 32 A
VDC: 600, 1,000 V
... disconnection of the DC lines present in the building. Disconnect switch equipped with motorized actuator, available for all versions of the Bremas DP, DK, DM and DX series. A single disconnect ...
BREMAS BETTER SWITCHES
Primary current: 500 A
VAC: 1,000 V
... Switch – disconnectors on-load available from 40A to 6300A in 3P – 3P+N & 4P versions (under request). Rated breaking current of up to 8 times the rated operational current, whit ability to establish and support short ...
Telergon
Primary current: 600 A - 3,000 A
VAC: 15.5 kV - 169 kV
... Air Break Switch (ABS) General Type: Manual Operation, Motor Operation and Earthing Switches Specifications: 15.5kV~169kV, 600A-3000A Motor operating voltage: AC 3 Phase 60Hz 220V Terminal pad: Both the size and measurement ...
Primary current: 900 A
VDC: 4,400 V
... LTK line disconnectors combines the Microelettrica heavy duty and well known technology on the high power circuit to the most advanced technology on the control and command circuit. This results in an innovative solution, which includes ...
Primary current: 40 A - 250 A
... Motorised switch disconnectors are intended to conduct remote make/break operations managed by electric control. They also offer local manual operation with padlockable handle providing circuit safe isolation during maintenance activities. ...
VDC: 750, 1,500, 3,000 V
... Segragated compartment for each Disconnector and/or Load Break Switch and for each cable incoming/outgoing. LBD DC Disconnecting Cubicles has a withdrawable execution on request. Segragated low voltage compartments ...
Primary current: 630 A
VAC: 24, 36 kV
... Insulated medium voltage overhead switch-disconnecter with SF6 and controlled manually or remotely with up to 36 kV. Installation on an overhead network. The NOGARIS OP overhead switch-disconnecter is installed ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group