Current transformers
Primary current: 60 A - 1,000 A
... Split-Core Current Transformers Thanks to their compact design, split-core current transformers are especially well suited for use in difficult to access locations and tight spaces. ...
Primary voltage: 4 kV
Secondary voltage: 4 kV
... Case in self-extinguishing UL94-V0 material Isolation voltage between primary and secondary: 4KV ...
... The HL Standard Current Transformer is a calibration standard designed for verification and error testing of current transformers. It consists of a primary winding and a secondary winding ...
... series current transformer is a meter relay gear that features an extended input range capacity, with maximum rated voltage of 1150 V. It obtains a frequency yield of 50 to 60 Hz, and rated load of 5 VA. This series offers ...
Primary current: 50 A - 2,000 A
Secondary current: 0.1, 1, 5 A
Primary current: 40 A
Secondary current: 400 A
... Bandwidth linear current transformer from 40A up to 400A. ...
Primary voltage: 720 V
Primary current: 30 A - 4,000 A
Secondary current: 5 A
... • Can be used with different busbar • Panel mount / Din rail mount (Optional accessory) • Certifications: CE, UL and ASTA Features : 1. Use with different busbar 2. Accuracy : Class 0.5 to 5 Rated Burden (VA) : 1VA to 15VA Accuracy : 0.5 to 5 Mounting ...
SELEC Controls Pvt. Ltd.
Electric power: 1 W - 60 W
Primary current: 15 A - 6,000 A
Frequency: 50, 60 Hz
... Current Transformers - 600V Class Frequency: 50 - 400 Hz Insulation Level: 600 Volts, 10 kV BILfull wave Applications: Ammeters, wattmeters, cross current compensation, energy management systems ...
Output power kVA: 7 kVA - 400 kVA
... Serra Norms Transformers. Powers: from 7 to 400 kVA. DIN Norms Transformers. Powers: from 40 to 150 kVA. Transformers for Seam Welders. Powers: from 130 to 210 kVA. Transformers for ...
Electric power: 75,000, 90,000, 110,000 W
Primary current: 100 A - 200 A
Secondary current: 100 mA
... Highly sensitive and accurate motor protection current transformer Maximum Input Current: upto 135A, 165A, 200A ...
Output power kVA: 170, 220, 120 kVA
Primary voltage: 500 V
Secondary voltage: 3.1, 11.3, 11 V
... series high frequency welding transformers are composed of rectifier modules, iron cores, windings, and water cooling cycles. They have the characteristics of low output secondary voltage, large current, and fast current ...
Primary current: 5 A
... Current transformers are designed to shrink the primary circuit current within the conversion ratio and transfer it to secondary circuit elements and to isolate the measurement and protection devices ...
Tense Electronic
Primary current: 5 A
... Model :CMCT102 Rated Input Current :5A Rated Output Current :2.5mA Turns Ratio :2000:1 Phase Angle Error :≤20'(Input 1A,sampling resistor 100Ω) Linear Range :0~20A(sampling resistor 100Ω) Mounting :Ø5.0mm ...
Cheemi Technology Co., Ltd
Primary current: 100, 1,000 A
... over 16A (e.g. EN61000-3-12) Precise measurement of high currents 100A and 1000 A Best accuracy 0,25% For middle and high frequencies 30Hz to 1 MHz Approved and adapted to expand precision power measuring ranges of ...
... Split Core Transformers are designed for installation in existing or new power installations. They can be installed on cables or copper bus without power disconnection Split Core transformers ...
Electric power: 100 W
Output power kVA: 0.12 kVA
Primary voltage: 220 V
... SINGLE PHASE TRANSFORMER 120VA (110W) Single phase 48V/230V 100W transformer suitable for satellite dish heaters. Suitable for transforming current (volts) from 48V to 230V. Can be combined with heating ...
... mounting with 4 fixing slots - DIN Rail Mounting Clip/Bracket accessory available (Part No. BZCT035/CP) A Core Balance Current Transformer (CBCT)/Toroid designed for use in conjunction with all Broyce “Type A” Earth ...
Broyce Control
Primary current: 50 A
... Current Sensor Features ·UL-Listed ·Output 0.333 Volt AC at rated current ·Operates from 50 Hz to 400 Hz ·Phase displacement < 1.0° at rated current ·Accuracy Class 1.0 ·8 ft. 18 ...
Primary current: 40 A - 80 A
... Operating temperature: -40~65℃ Primary Current (Amp.)50/60Hz: 40A-80A Accuracy @RL≦10Ω: Class 2% Turns ratio: 1:1000; 1:2000; ...