{{{product.idpText}}}
Primary voltage: 115, 230 V
Ignition transformers for high-voltage ignition of gas or oil burners, suitable for ignition and control with one electrode. Features & Benefits: Ignition voltage: 5 to 8 kV Duty cycle: 19 to 33% or continuous ...
Output power kVA: 0.03 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24 V
... temperature +40°C Benefits Bring energy to your automated systems! Phaseo is even more compactness and simplicity with 3 transformer offers to respond to every user requirement. New Universal double winding offer, ...
Primary voltage: 72 kV - 800 kV
... elements are subject to low electrical stress with high stability under extreme temperature variations. Applications • Revenue metering • Protective relaying • System control and indication of power ...
Primary current: 1 A - 5,000 A
... come up to. The new Compact Optical Sensor Intelligence, with Full IEC 61850 compliant and caters to both AC (up to 1200kV) and DC (up to 800kV). It contributes to Smarter Grids Networks to bring about changes for the ...
Step-up transformers are cohesive coils consisting of primary coils and secondary coils, and generate voltage that corresponds to turn ratios with mutual induction effects. TDK’s step-up transformers ...
Electric power: 0.1, 0.125, 0.15, 0.02 W
Primary current: 0.3 mA - 5,200 mA
Frequency: 400 Hz - 250,000 Hz
... -PRF-27, Grade 5, Class S. FREQUENCY RESPONSE:±3db, 400 Hz - 250 KHz at 1.0 Milliwatt. MAXIMUM DISTORTION: 5% With Rated Power Level at 1 KHz and 400 Hz. DIELECTRIC STRENGTH: All Units Tested at 200 V RMS. INSULATION ...
Electric power: 0.075 W - 0.83 W
Frequency: 400 Hz - 100,000 Hz
MIL-PRF-27: All units manufactured to MIL-PRF-27, Grade 5, Class S. DIELECTRIC STRENGTH: All Units Tested at 200 V RMS. INSULATION RESISTANCE: Greater Than 10,000 Megohms at 300 V DC. WEIGHT: 2.5 Grams. OPERATING TEMPERATURE: -55º ...
Primary voltage: 26, 115 V
Frequency: 400 Hz
Manufactured to MIL-PRF-27, Grade 5, Class S. 90º C Ambient. Regulation is 24% (T Units Have Regulation of 17%) Secondary Voltage Adjusted to Nominal Value at Half Load. Smallest Possible Size. Printed Circuit Thru Hole Construction. Secondary ...
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl
Frequency: 60, 50 Hz
... the supply of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection ...
Tesar Srl
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
The single-phase and three-phase transformers and auto-transformers are equipped with either copper or aluminum windings. These units feature air-type cooling and can perform up to 2000 kVA, with a frequency ...
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
Our 1-Ph and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to ...
Electric power: 0.1 kVA - 0.4 kVA
Primary voltage: 208 V - 480 V
Secondary voltage: 220 V
ATS Transformer Module is designed with pluggable terminal block to simplify ATS installation. Best use for system voltage 208 to 480 Vac. For system voltage from 208 to 480 Vac Modular design, simplify ATS ...
Electric power: 160,000 W
Primary voltage: 400 V
Secondary voltage: 480 V
Split- winding transformer Split-winding transformer separate the low voltage winding into 2 isolated parts, each winding can work individually or together. The advantage of the transformer. 1)Reduce ...
Electric power: 1,000 W - 1,000,000 W
Primary voltage: 220 V - 660 V
Secondary voltage: 5 V - 600 V
... loads generate harmonic currents that cause transformers and system neutrals to overheat, which can destroy the transformer. When a non-linear load is supplied from a transformer, ...
Different applications require different voltages, so transformers need to be more flexible. Chordn transformer offers you the flexibility that you need. Safe and reliable are the advantages of chordn ...
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 15 V - 400 V
Secondary voltage: 0 V - 230 V
MCL Range MCL Range Control Panel Transformers offering 230V and 400V with adjustment tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated winding and ...
Electric power: 0.05 kVA - 2.5 kVA
Primary voltage: 220 V - 415 V
Secondary voltage: 12, 24, 48, 115, 230 V
SCL Range SCL Range Control Panel Transformers offering 230V and 400V with adjustment tappings. Designed and manufactured to comply with IEC61558. This high quality product is manufactured using automated winding and ...
Transformers for switched sources are becoming more relevant in our production chain. These transformers are used in different applications and sectors. The types of switching power supplies ...
Transformadores JESIVA,S.L.
At JESIVA, we can design and manufacture any type of high frequency transformer under the specific request of the client. We highlight different types of special assemblies: Stacking of different core blocks. Wiring or ...
Transformadores JESIVA,S.L.
Primary voltage: 0.5 V - 1,000 V
Secondary voltage: 0.5 V - 1,000 V
... even auto resettable thermal protectors that act if windings overheat and if the transformer temperature drops. After that it works again automatically. - Transformers are manufactured under the EN-61558 ...
Transformadores JESIVA,S.L.
Electric power: 185 W - 3,000 W
Output power kVA: 40 kVA - 2,500 kVA
Primary voltage: 24 kV
The transformers can be available with oil expansion tank or hermetic version , and they are designed and manufactured according the following standards and equipped by the following accessories: • CEI EN 60076-1:2015 ...
Primary voltage: 230, 115 V
Frequency: 50 Hz - 60 Hz
... solder lug or quick connect) C UL US recognized (E207860) CE certified to IEC 950 (Approved to EN 60-742 Safety Isolating Transformers)
Hammond
Output power kVA: 70,000 kVA
Primary voltage: 110 kV
Furnace Transformer up to 110kV up tp 70MVA Product Usage Used for smelting high-quality alloy steel and ferroalloy in the metallurgical industry Used in steelmaking, iron, etc. in the iron ...
Primary voltage: 35 kV
Rectifier Transformer up to 35kV Product Usage Widely used in lighting, machine tool electrical appliances, mechanical and electronic equipment, medical equipment, rectifiers, etc. ...
Primary voltage: 230 V
Execution in accordance to VDE 0570 / EN 61558 Prepared for units to protective class II Protective type IP 00 Thermal class E Nominal ambient temperature ta 40°C Input voltage: 230V Output voltage: up to 42V Frequency: 50/60Hz Impregnation Test ...
Electric power: 0.022 kVA - 7.5 kVA
Primary voltage: 230 V
Secondary voltage: 6 V - 115 V
The isolating and safety-isolating transformer from Trafox, is equipped with a magnetic shield that covers the outer unit. This toroidal transformer comes with added insulation found within the windings, ...
Electric power: 0.015 kVA - 0.026 kVA
Primary voltage: 230 V
Secondary voltage: 6 V - 115 V
Transformers in the TF-series are suitable for devices with limited space and height. The transformers have a plastic mounting cup, which makes installation easy. At the same time, an adequate creeping ...
... requirements of our customers also in special circumstances. Our selection includes ferrite components, circuit board transformers, air-core components and needs. Our large-scale production takes place in Suzhou, ...
Primary voltage: 230, 220, 110 V
Secondary voltage: 7.1 V - 28.6 V
Primary current: 104 mA - 833 mA
... encapsulated,100℃/six hours high temperature aging,service life 20 years ,high dielectric strength. 2.High quality silicon steel sheet,Low temperature rise,High efficiency. 3.PBT project plastic, environmental protection ...
Primary voltage: 120, 115, 110 V
Secondary voltage: 8.9 V - 27.2 V
Primary current: 341 mA - 1,071 mA
Characteristics: Small magnetic flux leakage,low noise,hig effciency; No-load current small; PCB welding ; Suitable for senior acoustics,medical equipment,Military engineering,precision instruments Adopt the impirt high quality ...
Output power kVA: 0.01 kVA - 0.25 kVA
Primary voltage: 4 V - 250 V
Secondary voltage: 24 V
... 88 Series Transformers provide low voltage source from 50 to 250 volt amps for all large signaling installations. Holes provided in transformer housing for surface mounting. The Edwards 88 Series ...
Electric power: 90 kVA - 180 kVA
... Using the latest state-of-the-art technology and newest trends in the power electronics field and digital control, the APOJET AJT offers the best solution for aircraft ground power supply ...
Classification: Amorphous alloy phase-shifting rectifier transform
Chongqing Xianglong Electric Co., Ltd
Electric power: 0.0006 kVA - 0.0032 kVA
Primary voltage: 24 V - 440 V
Secondary voltage: 6 V - 24 V
... short-circuit-proof vaccum encapsulated, bobbin with dual chamber windings temperature class ta 40C/F and ta 70C/F hight electrical safety and long service-life properties quality test certified per item excellent temperature ...
HAHN - Elektrobau
Output power kVA: 10 kVA
Primary voltage: 600 V
Secondary voltage: 600 V
PhaseSingle FrequencyBased on customers' requirement Capacity10KVA Max. Voltage600V Max. Inductance RangeBased on customers' requirement Insulation LevelClass A / B / F
Leader Electronics Inc.
Cnomo type Transformers for automotion that included magnetothermics as protection.
EREMU
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining