- Electricity - Electronics >
- Energy: Production and Distribution >
- Current transformer
Current transformers
Primary current: 5 A - 1,000 A
... - Donut and Terminal Style that Reduce High AC Current Signals to 5 AC Amperes - Model 186 Reduces High AC Current Signals to 10 AC Volts ...
Primary voltage: 10 kV
Secondary voltage: 0.2 V - 10 V
Primary current: 5 A - 2,000 A
... Product Details
The LZMK-10
current
transformer maintains accuracy stability between -5~40C through thermally optimized casting structure. Unique
magnetic shunt design ensures composite ...
Ximai Electric (Wuhan) Co.,Ltd
Primary current: 0 A - 50 A
Frequency: 20 Hz - 2,000 Hz
... AC/DC current transformer (TRMS) to 4/20mA current loop, with isolation, high precision. 0…25 …50 A In alternating current it measures the true effective value (TRMS). In direct current ...
Output power kVA: 0, 0.01 kVA
Primary current: 10, 15, 25, 5 A
Frequency: 50, 60 Hz
... Protection transformers The C.T. when used as a current generator for protection relays has electrical characteristics which differ from those of the measuring transformer. In fact, the measuring ...
POLYLUX
Primary current: 6,000 A
... 0.66/K-Φ series current transformer General Current Transformer (CT) is used to transform the high AC current to small easily manageable values. ...
ACREL CO., LTD.
Primary voltage: 600 V
Secondary voltage: 333 mV
Primary current: 5 A - 600 A
... Split Core Current Transformer (Folder snap) Primary current: 5-600A Secondary voltage: 333mV US-CTV of split core style current transformers are designed for fast ...
ADTEK Electronics Co., Ltd
Output power kVA: 0.0015 kVA - 0.03 kVA
Primary current: 75 A - 4,000 A
Secondary current: 5 A
... between the secondary current and the primary current is close to zero. What are the Benefits of LV Current Transformer? Thanks to LV current transformers, ...
Output power kVA: 7.5 kVA
Primary voltage: 380, 360, 400 V
Secondary voltage: 56 V
... Overview: Three-phase Dry-type Transformer (for Photovoltaic): Applied in the photovoltaic field, it adapts the electrical energy generated by photovoltaic panels, optimizes voltage and current, and helps photovoltaic ...
LUSHAN CHINA
Primary current: 40 A - 300 A
Secondary current: 1, 5 A
... Primary Current Range 40A to 300A Secondary Current Options 5A or 1A Width 44mm Cable Aperture 21mm Cable 21mm Cable aperture Housing Features a sealable terminal cover Design Compact, making ...
Voltek Energy Limited
Primary current: 2,500 A - 4,000 A
... 12 - 24 kV Block Type Design Standard: IEC 60044-1/6, VDE0414, ANSI, GOST On request with capacitive layer On request with barrier ...
alce elektrik san ve tic as
Electric power: 0 kVA
Primary voltage: 0 V
Secondary voltage: 0 V
Federal Elektrik
Primary voltage: 0.7 kV
... Product Item : Current Transformer (0.66KV and below) Specification : SERIES NUMBER & SPECIFICATION Applicable standard: IEC, ANSI, CNS, JIS, JEC, BS Series & Types: 1.“CGZ” ZCT, for Relay, Indoor use, Epoxy Resin ...
Electric power: 40 W
Primary voltage: 12 V - 250 V
Primary current: 1 A
... Non-Contact Current Transformer Enhance your Smart Grid A non-contact current transformer measures three-phase current at line voltages to protect power ...
... Current Transformers MPR Family Accessories Temperature range: -40 +70 °C Box made with self-extinguishing material UL 94-VO Test voltage between primary and secondary: 4Kv ...
Orion Italia
... Sigma toroidal current transformer is used in combination with the leakage current protection LV circuit breaker, tripping coil and leakage current detection relay. The rules to be ...
SIGMA ELEKTRIK
Primary current: 100 A - 5,000 A
Frequency: 60, 50 Hz
... • Primary current: 100A-5000A • Sercondary current: 5A, 1A • Standard approval: IEC44-1, BS7626, VDE0414, VL94 • Maximum voltage: 0.72/3kV • Frequency: 50/60Hz • Rated load: 1VA-30VA • Class: 0.5, 1.0, 3.0 • Short-time ...
Primary current: 0.06 A - 85 A
Frequency: 0.1 Hz - 85 Hz
... and input currents ranging from mA up to 25 kA, the LILCO® series of PMK’s current transformers enables precision high bandwidth AC current measurements, which are required ...
Secondary voltage: 1, 5 V
Primary current: 1, 5 A
... series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used ...
BEIJING GFUVE ELECTRONICS CO.,LTD.
Primary current: 160 A
... audio plug connector(or customized), transient voltage suppressor built in. Application: used for the current measuring, monitoring and protecting of AC motor, lighting equipment and air compressor. ...
YHDC Dechang Electric
... This linear current transformer series, allow to obtain an AC or DC voltage on output without other transducer. This solution reduce the cost and space of the installation. Mechanical ...
Primary current: 5 A
... - nominal secondary current 5 A - rated burden 5 VA - working range 1 … 200 % of nominal current - uncertainty of ratio ± 0.001 % - uncertainty of phase ± 0.05 Min. - overload protection with indication ...
Primary current: 30 A
... Current transformers for energy meters single phase and three phase metering in Residential Metering applications. KEY FEATURES •High Linearity •Low cost •PCB Mountable •High Over current withstand ...
Electrohms
Secondary voltage: 65 V - 230 V
Primary current: 6.3, 3.15 A
... The SEA Series is a type of transformer in the Mf-net program manufactured by Vostermans Ventilation. The SEA series includes the SEA 3.15 and SEA 6.3. These transformers can be controlled manually, in semi-automatic ...
... 1. Current switches. These units are used to give a signal, if the AC current exceeds a preselected setpoint. The setpoint is adjusted on a potentiometer on the transformer. 2. Current ...
Output power kVA: 0.005 kVA
Primary voltage: 3 kV
Secondary voltage: 720, 333 V
... Article features 1. - This Winding current transformer is mostly used for new installations, as the circuit must be interrupted here. 2. - Most cost-effective and most common variant. 3. - Currently the most compact design ...
Celsa Messgeräte GmbH
Output power kVA: 2 kVA - 220 kVA
... WELDING TRANSFORMERS as always, TRE.CI designs and builds its own welding transformers. NGLE-PHASE WELDING TRANSFORMERS as always, TRE.CI designs and builds its For alternating current ...
Primary current: 50 A - 500 A
Secondary current: 1, 5 A
Frequency: 50 Hz - 60 Hz
... frequencies on request) • class of insulation E (other classes on request) • rated short-time thermal current Ith = 60 . IN • nominal surge current Idyn = 2.5 . Ith. • highest voltage for equipment Um = 0,72kV (other ...
CELSA MESSGERATE ESPAÑA S.L.
Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V
... The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase difference. The ...
Output power kVA: 30 kVA - 10,000 kVA
Frequency: 50, 60 Hz
... liquid-filled, pad-mounted (or padmount for short) transformers are all-in-one units designed, built, and tested in accordance with the highest industry standards and can be customized with over- current protection, and ...
Secondary voltage: 0.3 V
Primary current: 0 A - 600 A
Secondary current: 0 mA - 600 mA
... UL2808 XH-SCT-1250 Split Core Current Transformer CTs Specifications: 1.Rated current:0-600A 2.Rated output:mA or mV(0.333V) 3.Rated Voltage:0.66KV 4.Insulation Voltage:5400V CATIII 600V ...
Jiangyin Spark Electronic Technology Co.,LTD
... current and reduce it by transforming the current to a manageable value. The quality of SES Current Transformers have been proven and tested to comply in IEC: 44-1 (1996) standards, ...
Success Electronics & Transformer Manufacturer Sdn
Primary current: 15, 20, 5, 10 A
Secondary current: 2 mA - 20 mA
Frequency: 50, 60 Hz
... CURRENT TRANSFORMERS FOR ELECTRONIC ENERGY METERS FEATURES: -Adopted high permeability core, high accuracy, excellent linear performance; -Anti-combustion plastics case; -Encapsulated with epoxy resin with strong ...
Yueqing RunEasy Electronic Technology Co.,Ltd.
Electric power: 0.144, 0.096, 0.06, 0.12 kVA
Secondary voltage: 1.2, 0.8, 0.5 V
Primary current: 120, 0.6 A
... meters - Broad range of working currents - High allowable load impedance - High output power - Integration with the system The CTS-120 Current Separating Transformer was designed keeping ...
Primary voltage: 1,200, 720 V
Primary current: 40 A - 7,500 A
Secondary current: 1, 5 A
... of DEIF's current transformer range, these measuring transformers convert high current into lower nominal current value, thus making it possible to use instruments and ...
DEIF
Secondary voltage: 333, 100 mV
Primary current: 5 A - 600 A
Secondary current: 40, 100 mA
... ROHS Approved Electrical Specifications • Insulation Voltage : 600V AC • Measurement Range : 20%In~120%In • Accuracy : Class 0.5/Class 1 • Phase Angle : <2° at 50% Rated Current • Dielectric Strength : 2.5kV/1mA/1min Mechanical ...
Rayfull Electric Technology(Zhejiang)Co., Ltd.
Primary current: 100 A - 600 A
... split core current transformers designed for installation into existing plants where removal of busbars/cable lugs prevent installation of standard current transformers. To measure ...
inepro Metering BV
Electric power: 750, 1,000, 1,500, 2,000 kVA
Primary voltage: 40 V - 600 V
Secondary voltage: 23 V - 240 V
... Electromagnetic control components demand inrush currents up to 10 times the transformers nominal rating without sacrificing secondary voltage stability beyond practical limits. International Series transformers ...
Primary current: 400 A - 5,000 A
Secondary current: 5 A
... Toroidal Current Transformers are mostly used in cases where all measuring conductors cannot be passed through a toroidal current transformer. CT-1S provides a vectorial sum by using ...
Aktif Muhendislik Dis Tic. AS.
... Moulded case current transformers are used if high currents are to be recorded and further processed. The line to be measured (conductor rail or wire) is fed through the window opening and forms the primary ...
Janitza electronics GmbH
... Current rectifier and transformer The current rectifiers and transformers are so conceived as to be controlled by our OXIPRO, ELEPRO and ALUMASTER control systems in order to obtain ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.