- Electricity - Electronics >
- Switch and Relay >
- DIN rail monitoring relay
DIN rail monitoring relays
The ENTES Current Monitoring Relays are specially designed to offer protection to the motors and networks against under and over current conditions. The relays are available in four series ...
The product is composed of Voltage Monitoring Relays which are developed by entes. They are specifically designed for the protection of the motors and networks from undervoltage situations and overvoltage ...
Trigger voltage: 85 V - 480 V
... circuit, driving an electromechanical relay with one SPDT and one SPST contact. When correct voltage and phase rotation are applied, the internal relay will energize. A fault condition will de-energize ...
Trigger voltage: 24, 115, 230 V
... threshold relay for the monitoring or control of common types of process signals. The process signal to be monitored is selected on the front panel and the threshold value is also adjusted via a setpoint ...
Brodersen Controls
Trigger voltage: 24, 115, 230 V
Converts process signals for a pulsating output, which can be applied on the digital inputs of a PLC. Frequency output 0,05 - 5kHz or 0,5 - 50kHz.
Brodersen Controls
Trigger voltage: 24, 115, 230 V
MXV-10 Single phase voltage relay A relay for monitoring AC voltage on the supply network, in accordance with application of sensitive supply voltage equipment or as an alarm relay ...
Brodersen Controls
Trigger voltage: 24 V - 240 V
... safety relays offer outstanding simplicity, flexibility and cost-effectiveness. Their modular design simplifies the planning, commissioning and expansion of plants. Simple safety functions, such as EMERGENCY STOP and ...
Siemens Safety Integrated
Are you responsible for signal technology or safeguarded level crossings in the rail industry – or are you looking for the optimal process safety solution for your pipeline, turbine, or deep-sea application? The highest ...
Trigger voltage: 24 V - 230 V
Safety relays are intended to reliably monitor the signals from safety devices and switch off quickly in an emergency. Eaton’s ESR5 safety relays provide optimal safety and a high reliability for plant ...
Tripping current: 1, 4, 24 A
Trigger voltage: 24, 120, 30 V
... component failure DIN Rail or panel mount LED power on indicator The INT-04-024 or INT-04-120 Safety Relay is intended for use as a part of a safety circuit in emergency-stop of safety ...
EDWARDS SIGNALING
Trigger voltage: 110 V - 240 V
TE-RTD12 Motor RTD Monitor / Relay Device The TE-RTD12 Relay device adds advanced RTD (Resistor Temperature Detector) and differential current monitoring capability to your new or ...
... marine-approved. It ensures over speed and mandatory channels, such as low lube oil pressure and, high coolant temperature monitoring in order to shut down engine to prevent any damage.
Motor Management Relay The SEL-849 Relay offers current-, voltage-, and thermal-based motor protection; arc-flash detection; and power metering. It also provides all basic motor protection features, ...
Trigger voltage: 24 V - 240 V
... Current monitoring relay PRI-51 features its ability by controlling the heating of rods in shunts, of cables, to direct current flowing, to monitor utilization of single-phase electrical loads. This product ...
ETI
... The range includes relays suitable for installations with DIN rail, Panel or Base Mounting. All relays are suitable for use on a.c. systems and will be unaffected by ...
Tripping current: 0.02 A - 2 A
... Under or Over current monitoring (selectable) - 3 Selectable current ranges (0.2A, 1A or 2A) - Adjustable Trip level, Hysteresis and Time delay + Latch - Isolated Auxiliary supply - SPDT Relay output - ...
Broyce Control
Tripping current: 10 mA
Trigger voltage: 30, 250 V
... The module is based on the use of safety relays with guided contacts and can be configured both with automatic reset and manual reset. Furthermore, it has an auxiliary signaling output with relay, ...
WIDE Automation
... with LED indication of input status. Redundancy and cycle monitoring. Feedback loop for monitoring contacts or expansion modules. Short circuit and earth fault monitoring. 22mm ...
Idem Safety Switches
Trigger voltage: 0 V - 480 V
The SLU-100 series consists of various universal motor relays that were designed to provide a cost-effective protection solution against premature failure for various equipment, as well as against downtime that may be ...
Features •SIL 3 according to DIN EN 61508 and DIN EN 61511 •SIL CL 3 according to EN 62061 •Performance Level e according to DIN EN ISO 13849-1 •Safety category 4 according to ...
... as "simple apparatus", system certification is not needed. The slimline units are universal DIN-rail mounting and can be supplied pre-mounted in standard safe-area or flameproof enclosures as required.
... output relays, are self-monitoring, and are rated Control Reliable, which means that any fault in the safety-critical components will be detected and the machine will be rendered inoperative until the ...
Tapeswitch
Tripping current: 16 A
... AC 400 V. Output contact: 2x changeover/DPDT 16 A /250 V AC1. Sensitivity adjustable by potentiometer. 3-MODULE, DIN rail mounting.
ELKO
Trigger voltage: 100 V - 415 V
... network. The trip level is factory set and relay will operate after a delay of approximately two seconds. Relay is fail-safe and energises when powered. Link terminal 6 and 10 to make a non-latching ...
Meagacon AS
Tripping current: 0.1 A - 25 A
... current monitoring relays are used for the control of AC and DC current signal in various industrial and domestic applications. The measuring part of the instrument is metallically separated from the ...
The phase protection relays are designed to protect the three-phase loads from damage caused by mains voltage. High Voltage : 300V Low Voltage : 140V Asymmetry : 5% - 25% (Adjustable) Error Waiting ...
Tense Electronic
Trigger voltage: 24 V
• Master Control Unit • Dual Channel Output • LED and Volt Free Contact Indication • 35mm DIN Rail Mounting • Expandable upto 30 E'stops/Gates • Features an internal resettable fuse The EM1 ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve: