Tripping current: 500, 200 mA
Trigger voltage: 24 V
Self-monitoring, short-circuit proof inputs and outputs E-STOP with cross-fault monitoring and optional simultaneity monitoring Connection of mechanical safety switches and ...
ifm electronic
Tripping current: 200 mA
Trigger voltage: 24 V
... pulse comparison of two sensors Redundant structure of the hardware Redundant evaluation of the pulse sequences Relay with positively-driven contacts Four switch points selectable
ifm electronic
Tripping current: 125 mA
Trigger voltage: 24 V
Easy parameter setting via rotary switch Use of a large variety of cam discs Monitoring functions can be switched on and off Reliable operation at extreme ambient temperatures down to -40 °C Slim housing
ifm electronic
Trigger voltage: 12 V - 24 V
... PRO relay monitors undervoltage to protect motors and equipment from being damaged by blowouts. The multi timer can sense a maximum voltage of 24 V DC and has a single pole double throw ...
... module models have a variety of safety inputs, solid-state safety outputs and safety relay outputs • Innovative live display feature and diagnostics allow for active monitoring of I/O on a PC and assist ...
BANNER ENGINEERING CORP.
Trigger voltage: 24 V
... applications, such as photoelectric monitoring position or end-of-travelThe safety inputs can monitor:+24V dc solid-state (PNP) outputs in single-channel or dual-channel hookup+24V dc source that is switched by hard/relay ...
BANNER ENGINEERING CORP.
Trigger voltage: 12 V - 230 V
Modules monitor up to 10 external devices for contact failure or wiring faults Module goes into lockout mode if it detects a fault Available voltages include 24V dc 24V ac/dc 115V ac or 12 to 24V dc or 230V ...
BANNER ENGINEERING CORP.
Tripping current: 0 mA - 220 mA
... switching output OSSD Voltage type - AC/DC Switching element - Relay, NO Switching element - Relay, NO Type - Digital switching output Voltage type - AC/DC Switching element - Relay, ...
Leuze electronic GmbH + Co. KG
Tripping current: 6 A
Trigger voltage: 24 V
unctions - Cross circuit monitoring One- or two-channel operation Start/restart interlock (RES) Time-delayed shutdown (STOP1) Restart - Automatic Manual SIL - 3, IEC 61508 SILCL - 3, IEC/EN 62061 Performance ...
Leuze electronic GmbH + Co. KG
Tripping current: 1,000 mA
Trigger voltage: 20 V - 28 V
... - 105 mm x 58 mm x 103 mm Housing material - Plastic Net weight - 250 g Housing color - White Type of fastening - DIN rail mounting Snap-on mounting Ambient temperature, operation - -30 ... ...
Leuze electronic GmbH + Co. KG
Trigger voltage: 24, 120 V
Our Bulletin 700S-CF Safety Control Relays provide mechanically or mirror contact performance, which are required in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety ...
Allen-Bradley
... CONTACT EXPANSION RELAYS Contact expansion relays of the SNE family Have a redundant internal setup Used to increase the number of contacts STANDSTILL MONITORS Standstill ...
WIELAND ELECTRIC
Trigger voltage: 24 V
The Safety Control Module SBR031LC has three safety contacts, and one signal output. This product is great for processing potential-free outputs, emergency stop command devices, position switches or solenoid interlocks.
SCHMERSAL
Trigger voltage: 24 V
... is a two-function safety monitoring unit that uses a double evaluation setup and two enabling paths with their own shut-down setups. It uses an emergency exit opening to get both paths up. It also has a guard door ...
SCHMERSAL
Trigger voltage: 24 V
This device is an SRB 301AN model and it comes from a series of general process safety controllers. It features one signalling output and three safety connections, and also has a STOP 0 mechanism. It is highly useful for evaluating ...
SCHMERSAL
... provides different monitoring functions including over-/undervoltage and over-/underfrequency as well as rate of change of frequency (RoCoF) and vector shift monitoring functions, which detect a loss ...
ABB
Trigger voltage: 24 V - 240 V
... Insulation monitoring: The insulation monitor PMD s20 can be used to monitor the insulation resistance of unearthed AC/DC systems. Thanks to the separate supply voltage, monitoring ...
Trigger voltage: 0 V - 500 V
... electronic monitoring relays! Whether for monitoring voltage, phase sequence, current, insulation, true power, temperature, standstill or fault voltage, you will find the right device ...
Tripping current: 72 A
Trigger voltage: 230, 250 V
... ensure the necessary levels of personal and process safety, both in simple and in more complex systems. The easySafety control relay from Eaton's Moeller series combines both safety and control functions in one device. ...
The optimal scalability thanks to the modular construction prevents redundant inputs and outputs as well as reducing hardware Configuration via rotary switch simplifies logic configuration Flexi Classic configurator tool offers easy ...
SICK
Tripping current: 10, 6, 30 A
Trigger voltage: 220 V - 415 V
Electronic voltage monitoring relays for single and three-phase applications •Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window Mode, Phase ...
... as simple. When user needs change, it can be adapted quickly and easily to meet those needs. Unlike hard-wired safety relays, the Omron G9SP can be reconfigured to multiple purposes. Because it is a solid-state, ...
Tripping current: 5 A
Trigger voltage: 250, 30 V
... • OFF-delay models have 15-step OFF-delay settings. • Conforms to EN ISO13849-1 (PLe/Safety Category 4). • Both DIN track mounting and screw mounting are possible.
Trigger voltage: 24 V
... onto 35 mm C-profile rail. 4/2 safe inputs, 8/4 safe shutdown channels, 1 safe 1-channel potential-free relay contact. Contact multiplication or contact amplification by external contactors in connection ...
Trigger voltage: 24 V - 230 V
Modular isolation monitoring devices Sentinel Isolation monitoring sentinel for LV networks up to 500 Vac; 2 modules; 110–230–400 Vac power supply.
Tripping current: 20 mA
Trigger voltage: 24 V
... tampering is provided. • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary • Earth fault/ground fault ...
Tripping current: 0 A - 0.4 A
Trigger voltage: 24 V
... restarting semiconductor outputs or for external device monitoring (EDM) • 2 dual-channel outputs (PL e, category 4) • 4 test outputs for monitoring for short circuits and overload states • 2 monitoring ...
... According to EN 50156-1 for furnaces • 2-channel operation • Forcibly guided output contacts • With or without cross fault monitoring in the E-stop loop, switch S1 • Manual restart or automatic restart, switch S2 • ...
DOLD
The multifunctional safety module UG 6970 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. Up to two independent safety functions which are selected in a simple way ...
DOLD
The multifunctional safety timer UG 6960 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. The UG 6960 combines safety time functions and safety functions ...
DOLD
COMBI 6 Type B MULTI-CHANNEL EARTH LEAKAGE RELAY The Multichannel earth leakage relays COMBI 6 have been designed for the monitoring and protection of up to 6 independent systems. ...
... Type A,F & B MULTI-CHANNEL EARTH LEAKAGE RELAY The Multichannel earth leakage relays COMBI 6 have been designed for the monitoring and protection of up to 6 independent systems. A ...
... Leakage 2 DIN rail modules The earth leakage relays of the X...DL3 series are designed for intuitive and automatic detection of leakage currents. The special feature of these relays ...
The U1, the U1D, and the U1M, which are manufactured by Fanox, are single phase voltage relays that are DIN mounted. The U1 features two potentiometers, and the minimum and maximum thresholds can be modified. ...
Tripping current: 0 mA - 20 mA
Trigger voltage: 2 V - 10 V
The Monitoring Relay MR50Ex has inputs for industry standard signals 0/4..20 mA and 0/2..10 V DC. Measuring value and the programmed unit are shown in the display. The integrated transmitter supply offers ...
Trigger voltage: 24 V
Controllers monitor the safety field of several through-beam sensors. Interruption of the light beams results in the safety output being switched off. The individual light barrier controllers offer various operating modes, ...
Trigger voltage: 22 V - 29 V
... combination with the safety light curtains SG-I and safety light arrays SB-I, the relay unit allows for the interruption of safety-relevant circuits. Floating safety relays are utilized.
Trigger voltage: 24, 230 V
... , and cULus standards and come in a slim IEC style 17.5mm/0.69in footprint that snaps on a conventional DIN Rail. Besides the local settings, relays and terminals we also offer LED status ...
TELE Haase Steuergeraete GmbH
Trigger voltage: 690 V
... Series Phase Loss Monitor for up to 690V nominal voltage This product monitors phase loss, phase sequence, and phase rotation. The under-voltage settings can be adjusted locally from 180V to 690V. ...
TELE Haase Steuergeraete GmbH
Tripping current: 10 A
... is an AC current monitoring in 1-phase which is equipped with thresholds and hysteresis. The multifunction device also has tripping delay that helps in monitoring relays. It has various ...
TELE Haase Steuergeraete GmbH
Tripping current: 0.03 A - 5 A
... (main and prealarm / relay fault). Assembly on DIN rail 46277 (EN-50022). Locking the programming menu with the keyboard or sealing the PROG button. RCM and MRCD in the same unit 2 ...
Electronic earth leakage current intensity monitoring relay (IEC 62020), compatible with the WGC-TB series protection transformers. The RGU-10B is the most complete system of the range that monitors ...
Trigger voltage: 24 V
MZERO - A compact and configurable safety controller MZERO is a configurable safety hub able to manage all safety functions of a machinery or a plant. Configurable, allows cost reductions and minimal wiring. MZERO can manage ...
REER
Tripping current: 100 A
Trigger voltage: 24 V
... safety outputs, and the machine control circuits. * Guided-contact safety relays * Start/Restart interlock * EDM Feedback input for extra external contactors monitoring
REER
Tripping current: 6 A
... stop buttons and safety switches Safety relay for emergency stop buttons and safety switches monitoring. Guided-contact safety relays 2 N.A. + 1 N.C. EDM Feedback input for external ...
REER
Trigger voltage: 24 V
... disconnect, switch, or convert voltage - even where space is at a premium. Our product portfolio comprises a diversity of relay and optocoupler modules that use the practical terminal block format. Our analog transformers ...
MURRELEKTRONIK
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining