- Electricity - Electronics >
- Switch and Relay >
- Distribution switchgear fuse
Distribution switchgear fuses
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Amperage: 60 A - 100 A
VDC: 75 V
Service temperature: -55 °C - 100 °C
... single large-sized high-current industrial type fuse or in some cases, parallel configuration of lower amperage SMD fuses. The 881 Series fuses provide the option of a single fuse solution ...
Amperage: 2 A - 1,250 A
VAC: 400, 250, 500, 690, 440 V
... LV HRC fuse links are mainly used in LV HRC fuse bases, LV HRC fuse switch disconnectors, LV HRC fuse strips as well as in LV HRC in-line fuse switch disconnectors. LV ...
Amperage: 1 A - 600 A
Service temperature: -25 °C - 80 °C
... UL 248 • IEC 269-2-1 Amp-Trap fast-acting A4J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ...
Mersen - Electrical Power
Amperage: 50 A - 630 A
VDC: 1,500 V
... >
Applications
- Overcurrent protection in photovoltaic (PV) systems and DC distribution
- Integration in NH fuse holders and DC switchgear
- Industrial and commercial DC installations
Holly/Hollyfuse/Hollyland
Amperage: 50 A - 450 A
VDC: 1,500 V
... Product
NH1XLaBat is a DC
fuse designed to protect DC power circuits up to 1500 V DC. It covers a wide current range for industrial DC protection.
Key specifications
- Rated current: 50 A–450 A
- Rated
Holly/Hollyfuse/Hollyland
Amperage: 100 A - 250 A
VAC: 250 V
VDC: 170 V
... Product name
HE2aR
Overview
- The HE2aR is a high-current cartridge fuse designed for protection of power distribution, energy storage and industrial electrical equipment.
Key ...
Holly/Hollyfuse/Hollyland
... flow currents. The ETI HV fuse links time - current features conform to the norms of IEC IEC 60282-1. The unit also has an additional back up fuse. The ETI HV fuse links are used in interior and ...
Amperage: 0.5 A - 5 A
VDC: 7 kV - 41 kV
Length: 142 mm - 440 mm
... Fuses for capacitor banks Whether installed in smart substations that help master Germany’s energy transition or in switchgear whose voltage transformers have to meet strict customer requirements: ...
SIBA
Amperage: 100 A
VAC: 12 kV
... Technical parameters: PF: 42kV/min PD: 13.2kV <5pC Color: Red Cap Fuse Bushing Drawing and Technical Specifications ...
... bushings, then all the others that isolate the HV circuits, such as the SF6 medium voltage bushbar supports, the medium voltage fuse tubes and the medium voltage circuit breaker chambers. The small dimensions of this equipment place the ...
Amperage: 5 A - 180 A
VAC: 250 V
... Extremely high breaking capacity fuses: protection of power semiconductors as per IEC standard 60269.1 and 4 250 V voltage rating complying with IEC 33 gr class (ratings from 5 to 32 a) AS PER VDE 636-23 AND IEC 60269.4 aR CLASS ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group