- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Flow calibrator
Flow calibrators
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Temperature: 5 °C - 40 °C
Pressure: 0 bar - 2 bar
... supplied in a carrying case containing: the
calibrator, a CD with management software, a USB cable and a micrometer nozzle.
Measurement capability The T2730 uses a mass
flow sensor and can detect
flow ...
Temperature: 15 °C - 40 °C
... M2710 is the new digital portable calibrator of ForTest® M series. Enclosed in a container of anodized aluminium with shatterproof plexiglass front, we find a completely new circuit board and a mass flow meter sensor, ...
Temperature: 0 °C - 70 °C
Pressure: 1,344 mbar
Voltage: 100 V - 240 V
... the leading high- flow primary standard calibrator on the market today. The XL is used for calibration and verification of mass flow meters, controllers, variable area flow meters, and ...
Sierra Instruments
... Our laboratories are fully equipped to perform NIST traceable flow calibrations for Variable Area Flow Meters (Rotameters), Mass Flow Controllers and Mass Flow Meters. We offer calibration ...
Pressure: 40 bar
Voltage: 4, 5 V
... The operator can adjust the leak flow through a manual needle valve or enable/disable the simulated leak by simply pressing a button on the LCD display. The internal pressure sensor measures the line pressure, the flow ...
... long-term accuracy of the flow meter system. This high-precision instrument can be used to recalibrate Rosemount 8712 C/D/E, 8732 C/E, and the 8742C transmitters. The 8714D supplies an exact voltage, precisely simulating flow ...
... molbloc-Ls are laminar flow elements for use with molbox mass flow terminals. The molbloc flow path is the longitudinal, annular gap between a piston and a close fitting cylindrical bore in the molbloc ...
Temperature: -10 °C - 50 °C
Pressure: -100,000 Pa - 2,000,000 Pa
Voltage: -1 V - 60 V
... software for a complete documenting calibration system that produces calibration certificates automatically. Practicality in calibration The MC2 is a light, compact, and easy-to-use hand-held process calibrator. It ...
Beamex
Temperature: -100 °C - 1,200 °C
Pressure: 0 bar - 700 bar
Humidity range: 10 % - 98 %
... to +1200 °C • Calibration for humidity from 10 to 98 % r.h. at ambient temperatures from +10 to +95 °C • Calibration for flow velocities from 0.1 to 65 m/s • Calibration of electrical measured variables • Factory certificates for ...
... Descriptions Calibration Syringe of pulmonary function instrument Gasboard-7050 is mainly used for daily calibration and inspection of pulmonary function instrument or Spirometer. It adopts low traction piston, which is easy to operate, with high precision ...
Temperature: 5 °C - 45 °C
... you to check the calibration of leak and flow measurement instruments, as well as calibrated leaks and jets. This portable, compact and user-friendly instrument lets you adjust very accurately your leak or flow rate ...
Pressure: 0.6 MPa - 25 MPa
... of oxygen inhaler
- Flow-Pressure
... 4. easy operation 5. wide application range Features: 1.High precision mass flow controller Using two high-precision mass flow controllers, the gas distribution flow accuracy is high Large dilution ...
Temperature: 0 °C - 45 °C
... The Flow Detective™ is an easy to use all-in-one airflow calibrator that is suitable for all types of air sampling pumps and other applications for flows up to 5L/min. It is a rugged, compact lab or field ...
Temperature: 0 °C - 45 °C
... The Flow Detective™ is an easy to use all-in-one airflow calibrator that is suitable for all types of air sampling pumps and other applications for flows up to 5L/min. It is a rugged, compact lab or field ...
... switches and flow devices. Measurement mode provides a versatile precision micro-manometer that may be combined with laminar flow elements or pitot tubes for measurement of velocity, volumetric flow and ...
Temperature: -20 °C - 60 °C
Noise level: 100, 50 dB
Voltage: -500 V - 999 V
... Lighten up your toolbox Compact calibrator replaces toolbox of single function devices •Technician friendly operation Intuitive EZ-DIAL double click menu makes it easier to setup than other multifunction calibrators. ...
PIE - Pratical Instrument Electronics, Inc
Temperature: 5 °C - 40 °C
Voltage: 200 V - 240 V
... gas analyzer. Specifications Flow range of diluent gas::0~10SLPM Flow range of calibration gas: 0~100SCCM Accuracy of flow control: ±1%F.S. Linearity flow control: ±0.2%F.S. Repeatability ...
... Xavitech pumps, we have developed our Flow Calibration Unit (FCU). Connect the pump and the flow with only a few pushes of a button. When that is done, you can place the pump into your system with the desired flow. ...
Temperature: -20 °C - 55 °C
... establish communication with a Hart field instrument over the existing 4-20 mA DC lines, covering the five process variables of flow, pressure, temperature and level, control valve etc. FEATURES Common to most smart field Instruments ...
Temperature: -10 °C - 60 °C
Pressure: 45 psi
... AFS–Portable Gas Flow Calibrators A portable gas flow standard that is ready for anything When your calibration process requires the utmost accuracy, the AFS flow standard delivers. It ...
Alicat Scientific
Pressure: 10 bar
Voltage: 24 V
... The CM20 flow meter allows the monitoring of other flowmeters or leak master. Simply insert the control element between the regulated pressure source and the CM20 flowmeter and adjusted the pressure ...
Pressure: 16 bar
... Static Volume Method Water Flow Standard Device Categories : Calibration Systems and Standard Devices, Water calibration system Specifications • Flow rate range: (0 ~ 800) m3 / ...
Shanghai Powerbuilder Automation Technology Co. Ltd
Pressure: -0.8 bar - 10 bar
... suitable for universal use in all industrial environments and simulates leaks in flow, independent of pressure and temperature influences. Use as a leak instrument calibrator and leak simulator • High accuracy ...
... The Gas Flow Calibrator is a piston-prover-based test stand utilizing sonic nozzles to provide metrology for all gas metering technologies. This system: calibrates flow meters at pressures ranging from ...
... The portable calibration system Cal. flow enables high-precision flow calibrations according to the reference principle. The Cal. flow calibration system is used in ...
... microporous plankton samplers. It can quickly and accurately measure the flow of the sampler without increasing the load of the sampler, resulting in a large deviation of the flow before and after the test. The accuracy ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group