Fuses
Amperage: 200 mA - 5,000 mA
VAC: 125, 250 V
... FUNCTIONAL CHARACTERISTICS Testing current - Blow time 100% - 4 hours Min 130% - 1 hour Max 200% - 5 s Max Materials Fuse body: glass tube End cap: nickel plated brass Note The Voltage Drop values are measured at 100% rated ...
COMESTERO SISTEMI
Amperage: 2 A - 50 A
VDC: 1,500, 1,000 V
Breaking capacity: 20,000 A
... requirements, and the company will design according to the requirements) Relative air humidity: less than 90% This series of the fuse is suitable for solar photovoltaic power generation system, rated voltage to1500V, rated current ...
Amperage: 12 A
VDC: 1,000 V
Breaking capacity: 0 A - 33,000 A
... effective disconnection. A range of 10×38mm fuse links specifically designed for protecting photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted photovoltaic string ...
Amperage: 160 A - 1,000 A
... NT Low Voltage Fuse 1.Application NT low voltage H.R.C. fuse features light in weight, small in size, low in power loss and high in breaking capacity. This product has been widely used in overload and short circuit ...
Andeli Group Company
Amperage: 5 A - 180 A
VAC: 250 V
... Extremely high breaking capacity fuses: protection of power semiconductors as per IEC standard 60269.1 and 4 250 V voltage rating complying with IEC 33 gr class (ratings from 5 to 32 a) AS PER VDE 636-23 AND IEC 60269.4 aR CLASS ...
United Automation Limited
Amperage: 0.75 A - 5 A
VAC: 24, 40, 76 V
... Features Immediate cutting off against excessive current of circuit without generating heat and fuming. Excellent terminal strength and solderability due to metal electrode. Excellent dimension accuracy, mountability and shock-resistance due to plastic ...
KOA
Amperage: 2.5 A - 4 A
VAC: 125 V
VDC: 50 V
... - It is a fusible alloy type thermal links corresponding to RoHS. - It is excellent small in the thermosensing property. - It is non-return type of thermal links. It means even if the ambient temperature falls after the thermal link operates ...
Amperage: 0.2 A - 20 A
... WITH FLOW AND REFLOW SOLDERING SAFETY STANDARD APPROVAL (UL and c-UL File Number E302168) RECTANGULAR PACKAGE WITH METAL STRIP FUSE ELEMENT EIA SIZES 0402, 0603, 0805 AND 1206 CURRENT RATINGS UP TO 2.5 AMPS ...
NIC Components
... EXTERNAL FUSES The medium voltage capacitors and banks can be provided with external fuses to protect against faults caused by short-circuiting. External fuses used by Enerlux Power Srl: HRC FUSES EXPULSION ...
Amperage: 2 A - 1,000 A
... NT Low Voltage Fuse Application T low voltage H.R.C. fuse features light in weigth. small in size, low in power loss and high in breaking capacity. This product has been widely used in overload and short circuit protection ...
Amperage: 800 mA - 150,000 mA
VAC: 250 V
VDC: 80 V
... EATON, EDK, THERMODISC, FUZETEC, BELFUSE and TE. Within the line there are cylindrical fuses, PCB fuses, fuseholders, resettable and thermal fuses, in addition fuses and fuseholders ...
OMEGA FUSIBILI
VDC: 1,000, 1,500 V
Service temperature: -40 °C - 60 °C
... robust housing combined with the mating face of the Original MC4 connector, Stäubli offers the ideal fuse products for your PV-systems. The In-line Fuse 2 protects PV strings from over-current. Engineered & manufactured ...
Stäubli Electrical Connectors AG
Length: 32 mm - 38 mm
... Very fast acting fuses for protection of heating circuits ...
Amperage: 1, 4 A
... Application: Safety fuse with indicator LED, necessary during measuring operations on high power installations. Features: Profile to be integrated on lead tests POINTEST™ Can be connected to any accessory with ...
Amperage: 15 A
VAC: 250 V
M.A.E. S.r.l.
Amperage: 15 A
VAC: 250 V
M.A.E. S.r.l.
Amperage: 50 A
VAC: 32 V
M.A.E. S.r.l.
Amperage: 10 A
VAC: 240 V
... The KARI LS90 thermal fuse is a reliable safety device for applications in which high temperatures may cause serious damage to the equipment or constitute a fire hazard. A typical application is a heating station using oil as its energy ...
... insulators. 5, All our cutout fuses were type tested and design tested in accordance with IEC61952, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage. 6, The fuse ...
Amperage: 5 A - 15 A
... reliability. Finally, the fuses are laser-marked with current ratings (e.g., 5A, 10A, 15A) for easy identification. Each stage of the process benefits from HLC's automated inspection systems and strict quality controls, ensuring that ...
Amperage: 0.1 A - 30 A
VAC: 4 V - 400 V
VDC: 150 V - 750 V
Fuses in glass, ceramic, axial and radial bodies.
Amperage: 10, 15 A
VAC: 250 V
... RY01 series thermal fuse is a non-resetting protective device, which is used to prevent various electrical and heating appliance, dynamoelectric tools and industrial equipment from overheating. When the working temperature exceeds the ...
Focus Sensing and Control Technology Co.,LTD
... bushings, then all the others that isolate the HV circuits, such as the SF6 medium voltage bushbar supports, the medium voltage fuse tubes and the medium voltage circuit breaker chambers. The small dimensions of this equipment place the ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.