- Industrial machines and equipment >
- Heat Exchanger and Refrigeration >
- Glycol water cooler
Glycol water coolers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Maximum temperature: -10 °C - 35 °C
Flow rate: 5.6, 50 l/min
Pressure: 3.4 bar
... Industrial block pump with high pressure and high flow
LAUDA DR. R. WOBSER GMBH & CO. KG
Maximum temperature: -10 °C - 35 °C
Flow rate: 106, 43.8 l/min
Pressure: 6.8 Pa
... 14 W (
water-cooled).
Features
- Highly efficient industrial circulation chiller
- Electronic 2-point temperature control
- Integrated water filter
- Operates with non-flammable
LAUDA DR. R. WOBSER GMBH & CO. KG
Maximum temperature: -10 °C - 35 °C
Flow rate: 250, 292, 150 l/min
Pressure: 5, 5.6 bar
... features
- Industrial circulation chiller for process and test applications
- Industrial block pump with high pressure and high flow
- Compatible with non-flammable fluids (water, water/glycol)
- Operation
LAUDA DR. R. WOBSER GMBH & CO. KG
Power: 30,000, 35,000, 53,000 W
Cooling via high-performance compact impellers. The LCP draws in the air at the sides at the rear of the server enclosures and blows the cooled air back into the front part of the server enclosure at the sides.
Power: 16 kW - 37 kW
Maximum temperature: 15, 5, 20, 1 °C
Flow rate: 750 l/h - 4,000 l/h
... Integrated water circulation pump • Stainless steel harrow exchanger • Ice accumulation • Large-capacity insulated water tank • Operational management PLC • Water level management • Customisation ...
SOREMA
Power: 8 kW - 14 kW
Maximum temperature: 20, 15, 1, 5 °C
Flow rate: 350 l/h - 1,300 l/h
... height required: + 500 mm These chillers have been developed for industrial capacities ranging from 350 to 650 litres of water per hour. They are complemented by water dispensing options with cold ...
SOREMA
Power: 2 kW - 4.5 kW
Maximum temperature: 15, 20, 1, 5 °C
Flow rate: 110 l/h - 500 l/h
... output up to 0.5°C • Integrated water circulation pump • Remote control unit for managing automatic dispensing options and cold water / hot water mixing • Large-capacity insulated water ...
SOREMA
Power: 60 kW
Maximum temperature: -25 °C - 0 °C
Flow rate: 0 l/min - 140 l/min
Power: 0 kW - 0.6 kW
Maximum temperature: -20 °C - 80 °C
Flow rate: 0 l/min - 300 l/min
... oil/air cooler range is still setting the bench mark in the markets. We offer short lead times and the densest program of pressure resistant coolers with all relevant features. Our internal bypass options and pollution ...
... Waterloop is a commercial cooling system with indirect condensation. This system consists of refrigeration units condensed in a secondary water + ethylene glycol circuit and one or more air coolers ...
KIDE S.COOP
Power: 1,600 W - 30,000 W
... Vulcanic chillers are automatic units designed to cool all industrial or tooling processes by means of a circulating fluid ( water, glycol water or ISO VG2 oil, etc.). Due to its mobility ...
Power: 4.5 kW - 52.5 kW
Maximum temperature: -24 °C - 42 °C
... Extended operating limits: Tw in max = 0°C, Tw out min = -24°C with glycol; Tamb max = +42°C; Tamb min = -5°C; • IP54 electrical panel protection rate makes TAEevo LWT chillers suitable for outdoor installation; • ...
Power: 6 kW - 66 kW
Maximum temperature: 5 °C - 40 °C
Flow rate: 6 m³/h - 52 m³/h
... Air cooled scroll water chiller manufacturer 20STB series air cooled chiller adopts brand compressor and electronic control components processing and manufacturing, supporting efficient finned condenser, ...
H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.
... With our cooling water recoolers you can pre-select the desired temperature. This guarantees that it remains constant, which increases the service life of your tools. Our recooling systems also represent a closed cooling water ...
Power: 5 kW - 15,000 kW
... The glycol cooling model row of DELTATHERM® is characterized by an extremely economical and reliable operating as well as by a long lifespan. The glycol cooling program has a number of coolers ...
Power: 1,420 W - 81,680 W
Maximum temperature: 5 °C - 27 °C
Flow rate: 8 l/min - 366.7 l/min
... compressors with low energy consumption. • Electronic microprocessor thermoregulator for fluid temperature control and display. • Chiller malfunction signal display (except for ACW-LP 12 model and for optional features in other single-phase ...
EURO COLD
Power: 861 W - 59,700 W
Maximum temperature: 5 °C - 27 °C
... Recirculating Glycol Chillers from BV Thermal Systems are manufactured using the top quality components. Our recirculating Glycol chillers available in standard, benchtop, rackmount ...
Power: 250 kW - 1,200 kW
Maximum temperature: -10 °C - 12 °C
... Some years ago, Carrefour opened a new structure near Paris. It was a big supermarket with at least 40 cash registers. They decided to use, for this new store, the best cold technologies for food preservation. After an accurate research on the industrial ...
Power: 2.5 kW - 25 kW
Maximum temperature: -10 °C - 200 °C
Flow rate: 35, 50, 20, 75, 150 l/min
SUNDI system with feedforward with PV, the master PID loop operation results of the PV output and feedforward signals as the composite of the settings from the control loop, through such control of the temperature gradient, to ensure the accuracy of temperature ...
Power: 1,000 W
Maximum temperature: 0 °C - 65 °C
Flow rate: 12 l/min
... non-aqueous fluids, such as PAO (Poly-Alpha-Olefin) or Fluorinert / Galden / HFE. The system can also be configured for use with water/ glycol. Offering a cooling capacity of ~1,000 Watts @ 20°C with 20°C ambient temperature, ...
Power: 80 kW - 900 kW
... with pure water, without any addition of antifreeze liquid ( glycol), even in negative environment temperatures up to -15°C; this is made possible by an automatic discharge system of the finned exchangers ...
... The Cabinplant water chiller is of the Baudelot (falling film) type. Water flows uniformly from a common overhead distribution trough over both sides of the vertical stainless steel plates. The water ...
Maximum temperature: -40 °C - 120 °C
... temperature damage/start/operation The battery liquid cooler is specially used for thermal and fluid mechanics testing of liquid cooled battery packs. According to the requirements of the performance ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group